Update hb_confbridge.py to work like the DMRlink equivalent
Improved rule activation to include timeslot and resets, as well as not activating rules already activated, etc.
This commit is contained in:
parent
dc826bac59
commit
17e028700f
@ -370,17 +370,41 @@ class routerSYSTEM(HBSYSTEM):
|
||||
self._logger.info('(%s) Transmission match for Bridge: %s. Reset timeout to %s', self._system, _bridge, _system['TIMER'])
|
||||
|
||||
# TGID matches an ACTIVATION trigger
|
||||
if _dst_id in _system['ON']:
|
||||
if (_dst_id in _system['ON'] or _dst_id in _system['RESET']) and _slot == _system['TS']:
|
||||
# Set the matching rule as ACTIVE
|
||||
_system['ACTIVE'] = True
|
||||
_system['TIMER'] = pkt_time + _system['TIMEOUT']
|
||||
self._logger.info('(%s) Bridge: %s, connection changed to state: %s', self._system, _bridge, _system['ACTIVE'])
|
||||
if _dst_id in _system['ON']:
|
||||
if _system['ACTIVE'] == False:
|
||||
_system['ACTIVE'] = True
|
||||
_system['TIMER'] = pkt_time + _system['TIMEOUT']
|
||||
self._logger.info('(%s) Bridge: %s, connection changed to state: %s', self._system, _bridge, _system['ACTIVE'])
|
||||
# Cancel the timer if we've enabled an "OFF" type timeout
|
||||
if _system['TO_TYPE'] == 'OFF':
|
||||
_system['TIMER'] = now
|
||||
self._logger.info('(%s) Bridge: %s set to "OFF" with an on timer rule: timeout timer cancelled', self._system, _bridge)
|
||||
# Reset the timer for the rule
|
||||
if _system['ACTIVE'] == True and _system['TO_TYPE'] == 'ON':
|
||||
_system['TIMER'] = now + _system['TIMEOUT']
|
||||
self._logger.info('(%s) Bridge: %s, timeout timer reset to: %s', self._system, _bridge, _system['TIMER'] - now)
|
||||
|
||||
# TGID matches an DE-ACTIVATION trigger
|
||||
if _dst_id in _system['OFF']:
|
||||
if (_dst_id in _system['OFF'] or _dst_id in _system['RESET']) and _slot == _system['TS']:
|
||||
# Set the matching rule as ACTIVE
|
||||
_system['ACTIVE'] = False
|
||||
self._logger.info('(%s) Bridge: %s, connection changed to state: %s', self._system, _bridge, _system['ACTIVE'])
|
||||
if _dst_id in _system['OFF']:
|
||||
if _system['ACTIVE'] == True:
|
||||
_system['ACTIVE'] = False
|
||||
self._logger.info('(%s) Bridge: %s, connection changed to state: %s', self._system, _bridge, _system['ACTIVE'])
|
||||
# Cancel the timer if we've enabled an "ON" type timeout
|
||||
if _system['TO_TYPE'] == 'ON':
|
||||
_system['TIMER'] = now
|
||||
self._logger.info('(%s) Bridge: %s set to ON with and "OFF" timer rule: timeout timer cancelled', self._system, _bridge)
|
||||
# Reset the timer for the rule
|
||||
if _system['ACTIVE'] == False and _system['TO_TYPE'] == 'OFF':
|
||||
_system['TIMER'] = now + _system['TIMEOUT']
|
||||
self._logger.info('(%s) Bridge: %s, timeout timer reset to: %s', self._system, _bridge, _system['TIMER'] - now)
|
||||
# Cancel the timer if we've enabled an "ON" type timeout
|
||||
if _system['ACTIVE'] == True and _system['TO_TYPE'] == 'ON' and _dst_group in _system['OFF']:
|
||||
_system['TIMER'] = now
|
||||
self._logger.info('(%s) Bridge: %s set to ON with and "OFF" timer rule: timeout timer cancelled', self._system, _bridge)
|
||||
|
||||
#
|
||||
# END IN-BAND SIGNALLING
|
||||
|
@ -25,21 +25,23 @@ configuration file.
|
||||
a good value for documentation!
|
||||
* TIMOUT is a value in minutes for the timout timer. No, I won't make it 'seconds', so don't
|
||||
ask. Timers are performance "expense".
|
||||
|
||||
* RESET is a list of Talkgroup IDs that, in addition to the ON and OFF lists will cause a running
|
||||
timer to be reset. This is useful if you are using different TGIDs for voice traffic than
|
||||
triggering. If you are not, there is NO NEED to use this feature.
|
||||
'''
|
||||
|
||||
BRIDGES = {
|
||||
'WORLDWIDE': [
|
||||
{'SYSTEM': 'MASTER-1', 'TS': 1, 'TGID': 1, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'ON', 'ON': [2,], 'OFF': [9,10]},
|
||||
{'SYSTEM': 'CLIENT-1', 'TS': 1, 'TGID': 3100, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'ON', 'ON': [2,], 'OFF': [9,10]},
|
||||
{'SYSTEM': 'MASTER-1', 'TS': 1, 'TGID': 1, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'ON', 'ON': [2,], 'OFF': [9,10], 'RESET': []},
|
||||
{'SYSTEM': 'CLIENT-1', 'TS': 1, 'TGID': 3100, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'ON', 'ON': [2,], 'OFF': [9,10], 'RESET': []},
|
||||
],
|
||||
'ENGLISH': [
|
||||
{'SYSTEM': 'MASTER-1', 'TS': 1, 'TGID': 13, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'NONE', 'ON': [3,], 'OFF': [8,10]},
|
||||
{'SYSTEM': 'CLIENT-2', 'TS': 1, 'TGID': 13, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'NONE', 'ON': [3,], 'OFF': [8,10]},
|
||||
{'SYSTEM': 'MASTER-1', 'TS': 1, 'TGID': 13, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'NONE', 'ON': [3,], 'OFF': [8,10], 'RESET': []},
|
||||
{'SYSTEM': 'CLIENT-2', 'TS': 1, 'TGID': 13, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'NONE', 'ON': [3,], 'OFF': [8,10], 'RESET': []},
|
||||
],
|
||||
'STATEWIDE': [
|
||||
{'SYSTEM': 'MASTER-1', 'TS': 2, 'TGID': 3129, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'NONE', 'ON': [4,], 'OFF': [7,10]},
|
||||
{'SYSTEM': 'CLIENT-2', 'TS': 2, 'TGID': 3129, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'NONE', 'ON': [4,], 'OFF': [7,10]},
|
||||
{'SYSTEM': 'MASTER-1', 'TS': 2, 'TGID': 3129, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'NONE', 'ON': [4,], 'OFF': [7,10], 'RESET': []},
|
||||
{'SYSTEM': 'CLIENT-2', 'TS': 2, 'TGID': 3129, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'NONE', 'ON': [4,], 'OFF': [7,10], 'RESET': []},
|
||||
]
|
||||
}
|
||||
|
||||
|
Loading…