Restore XLXPEER functionality

This commit is contained in:
Dan Srebnick (K2IE) 2020-10-24 20:53:48 -04:00
parent d0d496b232
commit 4b9864671e
3 changed files with 116 additions and 20 deletions

View File

@ -182,7 +182,7 @@ def build_config(_config_file):
'SOFTWARE_ID': bytes(config.get(section, 'SOFTWARE_ID').ljust(40)[:40], 'utf-8'),
'PACKAGE_ID': bytes(config.get(section, 'PACKAGE_ID').ljust(40)[:40], 'utf-8'),
'GROUP_HANGTIME': config.getint(section, 'GROUP_HANGTIME'),
'OPTIONS': b''.join([b'Type=HBlink;', bytes(config.get(section, 'OPTIONS'), 'utf-8')]),
'OPTIONS': bytes(config.get(section, 'OPTIONS'), 'utf-8'),
'USE_ACL': config.getboolean(section, 'USE_ACL'),
'SUB_ACL': config.get(section, 'SUB_ACL'),
'TG1_ACL': config.get(section, 'TGID_TS1_ACL'),
@ -199,6 +199,52 @@ def build_config(_config_file):
'LAST_PING_ACK_TIME': 0,
}})
if config.get(section, 'MODE') == 'XLXPEER':
CONFIG['SYSTEMS'].update({section: {
'MODE': config.get(section, 'MODE'),
'ENABLED': config.getboolean(section, 'ENABLED'),
'LOOSE': config.getboolean(section, 'LOOSE'),
'SOCK_ADDR': (gethostbyname(config.get(section, 'IP')), config.getint(section, 'PORT')),
'IP': gethostbyname(config.get(section, 'IP')),
'PORT': config.getint(section, 'PORT'),
'MASTER_SOCKADDR': (gethostbyname(config.get(section, 'MASTER_IP')), config.getint(section, 'MASTER_PORT')),
'MASTER_IP': gethostbyname(config.get(section, 'MASTER_IP')),
'MASTER_PORT': config.getint(section, 'MASTER_PORT'),
'PASSPHRASE': bytes(config.get(section, 'PASSPHRASE'), 'utf-8'),
'CALLSIGN': bytes(config.get(section, 'CALLSIGN').ljust(8)[:8], 'utf-8'),
'RADIO_ID': config.getint(section, 'RADIO_ID').to_bytes(4, 'big'),
'RX_FREQ': bytes(config.get(section, 'RX_FREQ').ljust(9)[:9], 'utf-8'),
'TX_FREQ': bytes(config.get(section, 'TX_FREQ').ljust(9)[:9], 'utf-8'),
'TX_POWER': bytes(config.get(section, 'TX_POWER').rjust(2,'0'), 'utf-8'),
'COLORCODE': bytes(config.get(section, 'COLORCODE').rjust(2,'0'), 'utf-8'),
'LATITUDE': bytes(config.get(section, 'LATITUDE').ljust(8)[:8], 'utf-8'),
'LONGITUDE': bytes(config.get(section, 'LONGITUDE').ljust(9)[:9], 'utf-8'),
'HEIGHT': bytes(config.get(section, 'HEIGHT').rjust(3,'0'), 'utf-8'),
'LOCATION': bytes(config.get(section, 'LOCATION').ljust(20)[:20], 'utf-8'),
'DESCRIPTION': bytes(config.get(section, 'DESCRIPTION').ljust(19)[:19], 'utf-8'),
'SLOTS': bytes(config.get(section, 'SLOTS'), 'utf-8'),
'URL': bytes(config.get(section, 'URL').ljust(124)[:124], 'utf-8'),
'SOFTWARE_ID': bytes(config.get(section, 'SOFTWARE_ID').ljust(40)[:40], 'utf-8'),
'PACKAGE_ID': bytes(config.get(section, 'PACKAGE_ID').ljust(40)[:40], 'utf-8'),
'GROUP_HANGTIME': config.getint(section, 'GROUP_HANGTIME'),
'XLXMODULE': config.getint(section, 'XLXMODULE'),
'OPTIONS': '',
'USE_ACL': config.getboolean(section, 'USE_ACL'),
'SUB_ACL': config.get(section, 'SUB_ACL'),
'TG1_ACL': config.get(section, 'TGID_TS1_ACL'),
'TG2_ACL': config.get(section, 'TGID_TS2_ACL')
}})
CONFIG['SYSTEMS'][section].update({'XLXSTATS': {
'CONNECTION': 'NO', # NO, RTPL_SENT, AUTHENTICATED, CONFIG-SENT, YES
'CONNECTED': None,
'PINGS_SENT': 0,
'PINGS_ACKD': 0,
'NUM_OUTSTANDING': 0,
'PING_OUTSTANDING': False,
'LAST_PING_TX_TIME': 0,
'LAST_PING_ACK_TIME': 0,
}})
elif config.get(section, 'MODE') == 'MASTER':
CONFIG['SYSTEMS'].update({section: {
'MODE': config.get(section, 'MODE'),
@ -228,7 +274,6 @@ def build_config(_config_file):
'TARGET_SOCK': (gethostbyname(config.get(section, 'TARGET_IP')), config.getint(section, 'TARGET_PORT')),
'TARGET_IP': gethostbyname(config.get(section, 'TARGET_IP')),
'TARGET_PORT': config.getint(section, 'TARGET_PORT'),
'BOTH_SLOTS': config.getboolean(section, 'BOTH_SLOTS'),
'USE_ACL': config.getboolean(section, 'USE_ACL'),
'SUB_ACL': config.get(section, 'SUB_ACL'),
'TG1_ACL': config.get(section, 'TGID_ACL'),

View File

@ -120,9 +120,7 @@ STALE_DAYS: 7
#
# ACLs:
# OpenBridge does not 'register', so registration ACL is meaningless.
# Proper OpenBridge passes all traffic on TS1.
# HBlink can extend OPB to use both slots for unit calls only.
# Setting "BOTH_SLOTS" True ONLY affects unit traffic!
# OpenBridge passes all traffic on TS1, so there is only 1 TGID ACL.
# Otherwise ACLs work as described in the global stanza
[OBP-1]
MODE: OPENBRIDGE
@ -133,7 +131,6 @@ NETWORK_ID: 3129100
PASSPHRASE: password
TARGET_IP: 1.2.3.4
TARGET_PORT: 62035
BOTH_SLOTS: True
USE_ACL: True
SUB_ACL: DENY:1
TGID_ACL: PERMIT:ALL
@ -209,4 +206,36 @@ OPTIONS:
USE_ACL: True
SUB_ACL: DENY:1
TGID_TS1_ACL: PERMIT:ALL
TGID_TS2_ACL: PERMIT:ALL
TGID_TS2_ACL: PERMIT:ALL
[XLX-1]
MODE: XLXPEER
ENABLED: True
LOOSE: True
EXPORT_AMBE: False
IP:
PORT: 54002
MASTER_IP: 172.16.1.1
MASTER_PORT: 62030
PASSPHRASE: passw0rd
CALLSIGN: W1ABC
RADIO_ID: 312000
RX_FREQ: 449000000
TX_FREQ: 444000000
TX_POWER: 25
COLORCODE: 1
SLOTS: 1
LATITUDE: 38.0000
LONGITUDE: -095.0000
HEIGHT: 75
LOCATION: Anywhere, USA
DESCRIPTION: This is a cool repeater
URL: www.w1abc.org
SOFTWARE_ID: 20170620
PACKAGE_ID: MMDVM_HBlink
GROUP_HANGTIME: 5
XLXMODULE: 4004
USE_ACL: True
SUB_ACL: DENY:1
TGID_TS1_ACL: PERMIT:ALL
TGID_TS2_ACL: PERMIT:ALL

View File

@ -223,6 +223,13 @@ class HBSYSTEM(DatagramProtocol):
self.datagramReceived = self.peer_datagramReceived
self.dereg = self.peer_dereg
elif self._config['MODE'] == 'XLXPEER':
self._stats = self._config['XLXSTATS']
self.send_system = self.send_master
self.maintenance_loop = self.peer_maintenance_loop
self.datagramReceived = self.peer_datagramReceived
self.dereg = self.peer_dereg
def startProtocol(self):
# Set up periodic loop for tracking pings from peers. Run every 'PING_TIME' seconds
self._system_maintenance = task.LoopingCall(self.maintenance_loop)
@ -282,6 +289,29 @@ class HBSYSTEM(DatagramProtocol):
# KEEP THE FOLLOWING COMMENTED OUT UNLESS YOU'RE DEBUGGING DEEPLY!!!!
# logger.debug('(%s) TX Packet to %s:%s -- %s', self._system, self._config['MASTER_IP'], self._config['MASTER_PORT'], ahex(_packet))
def send_xlxmaster(self, radio, xlx, mastersock):
radio3 = int.from_bytes(radio, 'big').to_bytes(3, 'big')
radio4 = int.from_bytes(radio, 'big').to_bytes(4, 'big')
xlx3 = xlx.to_bytes(3, 'big')
streamid = randint(0,255).to_bytes(1, 'big')+randint(0,255).to_bytes(1, 'big')+randint(0,255).to_bytes(1, 'big')+randint(0,255).to_bytes(1, 'big')
# Wait for .5 secs for the XLX to log us in
for packetnr in range(5):
if packetnr < 3:
# First 3 packets, voice start, stream type e1
strmtype = 225
payload = bytearray.fromhex('4f2e00b501ae3a001c40a0c1cc7dff57d75df5d5065026f82880bd616f13f185890000')
else:
# Last 2 packets, voice end, stream type e2
strmtype = 226
payload = bytearray.fromhex('4f410061011e3a781c30a061ccbdff57d75df5d2534425c02fe0b1216713e885ba0000')
packetnr1 = packetnr.to_bytes(1, 'big')
strmtype1 = strmtype.to_bytes(1, 'big')
_packet = b''.join([DMRD, packetnr1, radio3, xlx3, radio4, strmtype1, streamid, payload])
self.transport.write(_packet, mastersock)
# KEEP THE FOLLOWING COMMENTED OUT UNLESS YOU'RE DEBUGGING DEEPLY!!!!
#logger.debug('(%s) XLX Module Change Packet: %s', self._system, ahex(_packet))
return
def dmrd_received(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _call_type, _frame_type, _dtype_vseq, _stream_id, _data):
pass
@ -489,18 +519,6 @@ class HBSYSTEM(DatagramProtocol):
self.transport.write(b''.join([MSTNAK, _peer_id]), _sockaddr)
logger.warning('(%s) Ping from Radio ID that is not logged in: %s', self._system, int_id(_peer_id))
elif _command == RPTO:
_peer_id = _data[4:8]
if _peer_id in self._peers \
and self._peers[_peer_id]['CONNECTION'] == 'YES' \
and self._peers[_peer_id]['SOCKADDR'] == _sockaddr:
logger.info('(%s) Peer %s (%s) has send options: %s', self._system, self._peers[_peer_id]['CALLSIGN'], int_id(_peer_id), _data[8:])
self.transport.write(b''.join([RPTACK, _peer_id]), _sockaddr)
elif _command == DMRA:
_peer_id = _data[4:8]
logger.info('(%s) Recieved DMR Talker Alias from peer %s, subscriber %s', self._system, self._peers[_peer_id]['CALLSIGN'], int_id(_rf_src))
else:
logger.error('(%s) Unrecognized command. Raw HBP PDU: %s', self._system, ahex(_data))
@ -630,7 +648,11 @@ class HBSYSTEM(DatagramProtocol):
self._stats['CONNECTION'] = 'YES'
self._stats['CONNECTED'] = time()
logger.info('(%s) Connection to Master Completed', self._system)
# If we are an XLX, send the XLX module request here.
if self._config['MODE'] == 'XLXPEER':
self.send_xlxmaster(self._config['RADIO_ID'], int(4000), self._config['MASTER_SOCKADDR'])
self.send_xlxmaster(self._config['RADIO_ID'], self._config['XLXMODULE'], self._config['MASTER_SOCKADDR'])
logger.info('(%s) Sending XLX Module request', self._system)
else:
self._stats['CONNECTION'] = 'NO'
logger.error('(%s) Master ACK Contained wrong ID - Connection Reset', self._system)