Fixed Private Call Bridging when BOTH_SLOTS selected

This is the problem where bridge.py is told to send private calls marked with EITHER timeslot over openbridge. Packets weren't assembled correctly when the BOTH_SLOTS option was set True in the hblink configuraiton file.
d:
#	modified:   bridge.py
#	modified:   hblink.py
#
# Changes not staged for commit:
#	modified:   .gitattributes
#	modified:   Dockerfile
#	modified:   voice_lib.py
#
This commit is contained in:
Cort Buffington 2020-04-27 11:01:54 -05:00
parent 24dca2e6ad
commit ccfd862a0a
5 changed files with 302 additions and 10 deletions

View File

@ -457,12 +457,14 @@ class routerOBP(OPENBRIDGE):
# This is a new call stream, so log & report
self.STATUS['START'] = pkt_time
logger.info('(%s) *UNIT CALL START* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) UNIT: %s (%s), TS: %s, FORWARD: %s', \
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot, self._targets)
if CONFIG['REPORTS']['REPORT']:
self._report.send_bridgeEvent('UNIT VOICE,START,RX,{},{},{},{},{},{},{}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id), self._targets).encode(encoding='utf-8', errors='ignore'))
# Record the time of this packet so we can later identify a stale stream
self.STATUS[_stream_id]['LAST'] = pkt_time
for _target in self._targets:
_target_status = systems[_target].STATUS
_target_system = self._CONFIG['SYSTEMS'][_target]
@ -486,12 +488,14 @@ class routerOBP(OPENBRIDGE):
# Record the time of this packet so we can later identify a stale stream
_target_status[_stream_id]['LAST'] = pkt_time
# Clear the TS bit and follow propper OBP definition, unless "BOTH_SLOTS" is set. This only works for unit calls.
if not _target_system['BOTH_SLOTS']:
if _target_system['BOTH_SLOTS']:
_tmp_bits = _bits
else:
_tmp_bits = _bits & ~(1 << 7)
# Assemble transmit HBP packet
_tmp_data = b''.join([_data[:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
_data = b''.join([_tmp_data, dmrpkt])
# Assemble transmit HBP packet
_tmp_data = b''.join([_data[:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
_data = b''.join([_tmp_data, dmrpkt])
if (_frame_type == HBPF_DATA_SYNC) and (_dtype_vseq == HBPF_SLT_VTERM):
_target_status[_stream_id]['ACTIVE'] = False
@ -558,7 +562,7 @@ class routerOBP(OPENBRIDGE):
# Final actions - Is this a voice terminator?
if (_frame_type == HBPF_DATA_SYNC) and (_dtype_vseq == HBPF_SLT_VTERM):
self._targets = []
call_duration = pkt_time - self.STATUS['START']
call_duration = pkt_time - self.STATUS[_stream_id]['START']
logger.info('(%s) *UNIT CALL END* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) UNIT %s (%s), TS %s, Duration: %.2f', \
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot, call_duration)
if CONFIG['REPORTS']['REPORT']:
@ -957,12 +961,14 @@ class routerHBP(HBSYSTEM):
# Record the time of this packet so we can later identify a stale stream
_target_status[_stream_id]['LAST'] = pkt_time
# Clear the TS bit and follow propper OBP definition, unless "BOTH_SLOTS" is set. This only works for unit calls.
if not _target_system['BOTH_SLOTS']:
if _target_system['BOTH_SLOTS']:
_tmp_bits = _bits
else:
_tmp_bits = _bits & ~(1 << 7)
# Assemble transmit HBP packet
_tmp_data = b''.join([_data[:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
_data = b''.join([_tmp_data, dmrpkt])
# Assemble transmit HBP packet
_tmp_data = b''.join([_data[:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
_data = b''.join([_tmp_data, dmrpkt])
if (_frame_type == HBPF_DATA_SYNC) and (_dtype_vseq == HBPF_SLT_VTERM):
_target_status[_stream_id]['ACTIVE'] = False

127
hblink-750.cfg Executable file
View File

@ -0,0 +1,127 @@
[GLOBAL]
PATH: ./
PING_TIME: 5
MAX_MISSED: 3
USE_ACL: False
REG_ACL: DENY:1
SUB_ACL: DENY:1
TGID_TS1_ACL: PERMIT:ALL
TGID_TS2_ACL: PERMIT:ALL
[REPORTS]
REPORT: False
REPORT_INTERVAL: 60
REPORT_PORT: 4321
REPORT_CLIENTS: 127.0.0.1
[LOGGER]
LOG_FILE: /tmp/hblink.log
LOG_HANDLERS: console-timed
LOG_LEVEL: INFO
LOG_NAME: 444.750
[ALIASES]
TRY_DOWNLOAD: False
PATH: ./
PEER_FILE: peer_ids.json
SUBSCRIBER_FILE: subscriber_ids.json
TGID_FILE: talkgroup_ids.json
PEER_URL: https://www.radioid.net/static/rptrs.json
SUBSCRIBER_URL: https://www.radioid.net/static/users.json
STALE_DAYS: 7
[OBP]
MODE: OPENBRIDGE
ENABLED: True
IP:
PORT: 50100
NETWORK_ID: 1
PASSPHRASE: deadbeef
#TARGET_IP: olympic.k0usy.org
TARGET_IP: 127.0.0.1
#TARGET_PORT: 50666
TARGET_PORT: 50101
BOTH_SLOTS: True
USE_ACL: False
SUB_ACL: DENY:1
TGID_ACL: PERMIT:ALL
[444.750]
MODE: MASTER
ENABLED: True
REPEAT: True
MAX_PEERS: 5
EXPORT_AMBE: False
IP:
PORT: 50001
PASSPHRASE: jimmy
GROUP_HANGTIME: 10
USE_ACL: False
REG_ACL: DENY:1
SUB_ACL: DENY:1
TGID_TS1_ACL: DENY:8
TGID_TS2_ACL: PERMIT:3120
[TWO]
MODE: MASTER
ENABLED: False
REPEAT: True
MAX_PEERS: 5
EXPORT_AMBE: False
IP:
PORT:50002
PASSPHRASE: jimmy
GROUP_HANGTIME: 10
USE_ACL: False
REG_ACL: DENY:1
SUB_ACL: DENY:1
TGID_TS1_ACL: DENY:8
TGID_TS2_ACL: PERMIT:3120
[THREE]
MODE: MASTER
ENABLED: False
REPEAT: True
MAX_PEERS: 5
EXPORT_AMBE: False
IP:
PORT:50003
PASSPHRASE: jimmy
GROUP_HANGTIME: 10
USE_ACL: False
REG_ACL: DENY:1
SUB_ACL: DENY:1
TGID_TS1_ACL: DENY:8
TGID_TS2_ACL: PERMIT:3120
[KS-DMR]
MODE: PEER
ENABLED: False
LOOSE: False
EXPORT_AMBE: False
IP:
PORT: 54001
MASTER_IP: olympic.k0usy.org
MASTER_PORT: 62071
PASSPHRASE: c0ffee
CALLSIGN: W1ABC
RADIO_ID: 312312
RX_FREQ: 449000000
TX_FREQ: 444000000
TX_POWER: 25
COLORCODE: 1
SLOTS: 1
LATITUDE: 38.0000
LONGITUDE: -095.0000
HEIGHT: 75
LOCATION: Anywhere, USA
DESCRIPTION: This is a cool repeater
URL: www.w1abc.org
SOFTWARE_ID: 20170620
PACKAGE_ID: MMDVM_HBlink
GROUP_HANGTIME: 5
OPTIONS:
USE_ACL: True
SUB_ACL: DENY:1
TGID_TS1_ACL: PERMIT:ALL
TGID_TS2_ACL: PERMIT:ALL

127
hblink-800.cfg Executable file
View File

@ -0,0 +1,127 @@
[GLOBAL]
PATH: ./
PING_TIME: 5
MAX_MISSED: 3
USE_ACL: False
REG_ACL: DENY:1
SUB_ACL: DENY:1
TGID_TS1_ACL: PERMIT:ALL
TGID_TS2_ACL: PERMIT:ALL
[REPORTS]
REPORT: False
REPORT_INTERVAL: 60
REPORT_PORT: 4321
REPORT_CLIENTS: 127.0.0.1
[LOGGER]
LOG_FILE: /tmp/hblink.log
LOG_HANDLERS: console-timed
LOG_LEVEL: INFO
LOG_NAME: 444.800
[ALIASES]
TRY_DOWNLOAD: False
PATH: ./
PEER_FILE: peer_ids.json
SUBSCRIBER_FILE: subscriber_ids.json
TGID_FILE: talkgroup_ids.json
PEER_URL: https://www.radioid.net/static/rptrs.json
SUBSCRIBER_URL: https://www.radioid.net/static/users.json
STALE_DAYS: 7
[OBP]
MODE: OPENBRIDGE
ENABLED: True
IP:
PORT: 50101
NETWORK_ID: 2
PASSPHRASE: deadbeef
#TARGET_IP: olympic.k0usy.org
TARGET_IP: 127.0.0.1
#TARGET_PORT: 50666
TARGET_PORT: 50100
BOTH_SLOTS: True
USE_ACL: False
SUB_ACL: DENY:1
TGID_ACL: PERMIT:ALL
[444.800]
MODE: MASTER
ENABLED: True
REPEAT: True
MAX_PEERS: 5
EXPORT_AMBE: False
IP:
PORT: 50011
PASSPHRASE: jimmy
GROUP_HANGTIME: 10
USE_ACL: False
REG_ACL: DENY:1
SUB_ACL: DENY:1
TGID_TS1_ACL: DENY:8
TGID_TS2_ACL: PERMIT:3120
[TWO]
MODE: MASTER
ENABLED: False
REPEAT: True
MAX_PEERS: 5
EXPORT_AMBE: False
IP:
PORT:50012
PASSPHRASE: jimmy
GROUP_HANGTIME: 10
USE_ACL: False
REG_ACL: DENY:1
SUB_ACL: DENY:1
TGID_TS1_ACL: DENY:8
TGID_TS2_ACL: PERMIT:3120
[THREE]
MODE: MASTER
ENABLED: False
REPEAT: True
MAX_PEERS: 5
EXPORT_AMBE: False
IP:
PORT:50013
PASSPHRASE: jimmy
GROUP_HANGTIME: 10
USE_ACL: False
REG_ACL: DENY:1
SUB_ACL: DENY:1
TGID_TS1_ACL: DENY:8
TGID_TS2_ACL: PERMIT:3120
[KS-DMR]
MODE: PEER
ENABLED: False
LOOSE: False
EXPORT_AMBE: False
IP:
PORT: 54011
MASTER_IP: olympic.k0usy.org
MASTER_PORT: 62071
PASSPHRASE: c0ffee
CALLSIGN: W1ABC
RADIO_ID: 312312
RX_FREQ: 449000000
TX_FREQ: 444000000
TX_POWER: 25
COLORCODE: 1
SLOTS: 1
LATITUDE: 38.0000
LONGITUDE: -095.0000
HEIGHT: 75
LOCATION: Anywhere, USA
DESCRIPTION: This is a cool repeater
URL: www.w1abc.org
SOFTWARE_ID: 20170620
PACKAGE_ID: MMDVM_HBlink
GROUP_HANGTIME: 5
OPTIONS:
USE_ACL: True
SUB_ACL: DENY:1
TGID_TS1_ACL: PERMIT:ALL
TGID_TS2_ACL: PERMIT:ALL

16
rules-750.py Executable file
View File

@ -0,0 +1,16 @@
BRIDGES = {
'1/2': [
{'SYSTEM': '444.750', 'TS': 1, 'TGID': 2, 'ACTIVE': True, 'TIMEOUT': 5,'TO_TYPE': 'NONE', 'ON': [], 'OFF': [], 'RESET': []},
{'SYSTEM': 'OBP', 'TS': 1, 'TGID': 2, 'ACTIVE': True, 'TIMEOUT': 5,'TO_TYPE': 'NONE', 'ON': [], 'OFF': [], 'RESET': []}
],
'KANSAS': [
{'SYSTEM': '444.750', 'TS': 2, 'TGID': 3120, 'ACTIVE': True, 'TIMEOUT': 5,'TO_TYPE': 'NONE', 'ON': [], 'OFF': [], 'RESET': []},
{'SYSTEM': 'OBP', 'TS': 1, 'TGID': 3120, 'ACTIVE': True, 'TIMEOUT': 5,'TO_TYPE': 'NONE', 'ON': [], 'OFF': [], 'RESET': []}
]
}
UNIT = ['444.750', 'OBP']
if __name__ == '__main__':
from pprint import pprint
pprint(BRIDGES)

16
rules-800.py Executable file
View File

@ -0,0 +1,16 @@
BRIDGES = {
'1/2': [
{'SYSTEM': '444.800', 'TS': 1, 'TGID': 2, 'ACTIVE': True, 'TIMEOUT': 5,'TO_TYPE': 'NONE', 'ON': [], 'OFF': [], 'RESET': []},
{'SYSTEM': 'OBP', 'TS': 1, 'TGID': 2, 'ACTIVE': True, 'TIMEOUT': 5,'TO_TYPE': 'NONE', 'ON': [], 'OFF': [], 'RESET': []}
],
'KANSAS': [
{'SYSTEM': '444.800', 'TS': 2, 'TGID': 3120, 'ACTIVE': True, 'TIMEOUT': 5,'TO_TYPE': 'NONE', 'ON': [], 'OFF': [], 'RESET': []},
{'SYSTEM': 'OBP', 'TS': 1, 'TGID': 3120, 'ACTIVE': True, 'TIMEOUT': 5,'TO_TYPE': 'NONE', 'ON': [], 'OFF': [], 'RESET': []}
]
}
UNIT = ["444.800", "OBP"]
if __name__ == '__main__':
from pprint import pprint
pprint(BRIDGES)