Removed timers, add disconnect/reconnect to make the conntion more reliable
This commit is contained in:
parent
bce4e01775
commit
02c605dab7
@ -33,7 +33,7 @@ from binascii import a2b_hex as bhex
|
||||
from random import randint
|
||||
from hashlib import sha256, sha1
|
||||
from hmac import new as hmac_new, compare_digest
|
||||
from time import time, sleep
|
||||
from time import time
|
||||
from collections import deque
|
||||
|
||||
# Twisted is pretty important, so I keep it separate
|
||||
@ -296,7 +296,6 @@ class HBSYSTEM(DatagramProtocol):
|
||||
xlx3 = xlx.to_bytes(3, 'big')
|
||||
streamid = randint(0,255).to_bytes(1, 'big')+randint(0,255).to_bytes(1, 'big')+randint(0,255).to_bytes(1, 'big')+randint(0,255).to_bytes(1, 'big')
|
||||
# Wait for .5 secs for the XLX to log us in
|
||||
sleep(.500)
|
||||
for packetnr in range(5):
|
||||
if packetnr < 3:
|
||||
# First 3 packets, voice start, stream type e1
|
||||
@ -309,7 +308,6 @@ class HBSYSTEM(DatagramProtocol):
|
||||
packetnr1 = packetnr.to_bytes(1, 'big')
|
||||
strmtype1 = strmtype.to_bytes(1, 'big')
|
||||
_packet = b''.join([DMRD, packetnr1, radio3, xlx3, radio4, strmtype1, streamid, payload])
|
||||
sleep(.100)
|
||||
self.transport.write(_packet, mastersock)
|
||||
# KEEP THE FOLLOWING COMMENTED OUT UNLESS YOU'RE DEBUGGING DEEPLY!!!!
|
||||
#logger.debug('(%s) XLX Module Change Packet: %s', self._system, ahex(_packet))
|
||||
@ -665,6 +663,7 @@ class HBSYSTEM(DatagramProtocol):
|
||||
logger.info('(%s) Connection to Master Completed', self._system)
|
||||
# If we are an XLX, send the XLX module request here.
|
||||
if self._config['MODE'] == 'XLXPEER':
|
||||
self.send_xlxmaster(self._config['RADIO_ID'], int(4000), self._config['MASTER_SOCKADDR'])
|
||||
self.send_xlxmaster(self._config['RADIO_ID'], self._config['XLXMODULE'], self._config['MASTER_SOCKADDR'])
|
||||
logger.info('(%s) Sending XLX Module request', self._system)
|
||||
else:
|
||||
|