Fix timer on reflectors

This commit is contained in:
Simon 2020-11-14 10:45:45 +00:00
parent d076096faa
commit 4aae0302e0
1 changed files with 3 additions and 2 deletions

View File

@ -1187,9 +1187,10 @@ class routerHBP(HBSYSTEM):
_nine = bytes_3(9)
_int_dst_id = int_id(_dst_id)
#Handle private calls (for reflectors)
if _call_type == 'unit' and _slot == 2:
_int_dst_id = int_id(_dst_id)
if (_stream_id != self.STATUS[_slot]['RX_STREAM_ID']):
logger.warning('(%s) Reflector: Private call from %s to %s',self._system, int_id(_rf_src), _int_dst_id)
#if _int_dst_id >= 4000 and _int_dst_id <= 5000:
@ -1386,7 +1387,7 @@ class routerHBP(HBSYSTEM):
# Iterate the rules dictionary
BRIDGE_SEMA.acquire(blocking = True)
for _bridge in BRIDGES:
if _bridge[0:1] == '#':
if _bridge[0:1] == '#' and _int_dst_id != 9:
continue
for _system in BRIDGES[_bridge]:
if _system['SYSTEM'] == self._system: