@ -711,27 +711,50 @@ class routerHBP(HBSYSTEM):
|
|||||||
|
|
||||||
# TGID matches an DE-ACTIVATION trigger
|
# TGID matches an DE-ACTIVATION trigger
|
||||||
#Single TG mode
|
#Single TG mode
|
||||||
if (_dst_id in _system['OFF'] or _dst_id in _system['RESET'] or _dst_id != _system['TGID']) and _slot == _system['TS']:
|
if (CONFIG['SYSTEMS'][self._system]['SINGLE_MODE']) == True:
|
||||||
#if (_dst_id in _system['OFF'] or _dst_id in _system['RESET']) and _slot == _system['TS']:
|
if (_dst_id in _system['OFF'] or _dst_id in _system['RESET'] or _dst_id != _system['TGID']) and _slot == _system['TS']:
|
||||||
# Set the matching rule as ACTIVE
|
#if (_dst_id in _system['OFF'] or _dst_id in _system['RESET']) and _slot == _system['TS']:
|
||||||
#Single TG mode
|
# Set the matching rule as ACTIVE
|
||||||
if _dst_id in _system['OFF'] or _dst_id != _system['TGID']:
|
#Single TG mode
|
||||||
#if _dst_id in _system['OFF']:
|
if _dst_id in _system['OFF'] or _dst_id != _system['TGID']:
|
||||||
if _system['ACTIVE'] == True:
|
#if _dst_id in _system['OFF']:
|
||||||
_system['ACTIVE'] = False
|
if _system['ACTIVE'] == True:
|
||||||
logger.info('(%s) Bridge: %s, connection changed to state: %s', self._system, _bridge, _system['ACTIVE'])
|
_system['ACTIVE'] = False
|
||||||
# Cancel the timer if we've enabled an "ON" type timeout
|
logger.info('(%s) Bridge: %s, connection changed to state: %s', self._system, _bridge, _system['ACTIVE'])
|
||||||
|
# Cancel the timer if we've enabled an "ON" type timeout
|
||||||
if _system['TO_TYPE'] == 'ON':
|
if _system['TO_TYPE'] == 'ON':
|
||||||
_system['TIMER'] = pkt_time
|
_system['TIMER'] = pkt_time
|
||||||
logger.info('(%s) Bridge: %s set to ON with and "OFF" timer rule: timeout timer cancelled', self._system, _bridge)
|
logger.info('(%s) Bridge: %s set to ON with and "OFF" timer rule: timeout timer cancelled', self._system, _bridge)
|
||||||
# Reset the timer for the rule
|
# Reset the timer for the rule
|
||||||
if _system['ACTIVE'] == False and _system['TO_TYPE'] == 'OFF':
|
if _system['ACTIVE'] == False and _system['TO_TYPE'] == 'OFF':
|
||||||
_system['TIMER'] = pkt_time + _system['TIMEOUT']
|
_system['TIMER'] = pkt_time + _system['TIMEOUT']
|
||||||
logger.info('(%s) Bridge: %s, timeout timer reset to: %s', self._system, _bridge, _system['TIMER'] - pkt_time)
|
logger.info('(%s) Bridge: %s, timeout timer reset to: %s', self._system, _bridge, _system['TIMER'] - pkt_time)
|
||||||
# Cancel the timer if we've enabled an "ON" type timeout
|
# Cancel the timer if we've enabled an "ON" type timeout
|
||||||
if _system['ACTIVE'] == True and _system['TO_TYPE'] == 'ON' and _dst_id in _system['OFF']:
|
if _system['ACTIVE'] == True and _system['TO_TYPE'] == 'ON' and _dst_id in _system['OFF']:
|
||||||
_system['TIMER'] = pkt_time
|
_system['TIMER'] = pkt_time
|
||||||
logger.info('(%s) Bridge: %s set to ON with and "OFF" timer rule: timeout timer cancelled', self._system, _bridge)
|
logger.info('(%s) Bridge: %s set to ON with and "OFF" timer rule: timeout timer cancelled', self._system, _bridge)
|
||||||
|
else:
|
||||||
|
|
||||||
|
if (_dst_id in _system['OFF'] or _dst_id in _system['RESET']) and _slot == _system['TS']:
|
||||||
|
#if (_dst_id in _system['OFF'] or _dst_id in _system['RESET']) and _slot == _system['TS']:
|
||||||
|
# Set the matching rule as ACTIVE
|
||||||
|
if _dst_id in _system['OFF']:
|
||||||
|
#if _dst_id in _system['OFF']:
|
||||||
|
if _system['ACTIVE'] == True:
|
||||||
|
_system['ACTIVE'] = False
|
||||||
|
logger.info('(%s) Bridge: %s, connection changed to state: %s', self._system, _bridge, _system['ACTIVE'])
|
||||||
|
# Cancel the timer if we've enabled an "ON" type timeout
|
||||||
|
if _system['TO_TYPE'] == 'ON':
|
||||||
|
_system['TIMER'] = pkt_time
|
||||||
|
logger.info('(%s) Bridge: %s set to ON with and "OFF" timer rule: timeout timer cancelled', self._system, _bridge)
|
||||||
|
# Reset the timer for the rule
|
||||||
|
if _system['ACTIVE'] == False and _system['TO_TYPE'] == 'OFF':
|
||||||
|
_system['TIMER'] = pkt_time + _system['TIMEOUT']
|
||||||
|
logger.info('(%s) Bridge: %s, timeout timer reset to: %s', self._system, _bridge, _system['TIMER'] - pkt_time)
|
||||||
|
# Cancel the timer if we've enabled an "ON" type timeout
|
||||||
|
if _system['ACTIVE'] == True and _system['TO_TYPE'] == 'ON' and _dst_id in _system['OFF']:
|
||||||
|
_system['TIMER'] = pkt_time
|
||||||
|
logger.info('(%s) Bridge: %s set to ON with and "OFF" timer rule: timeout timer cancelled', self._system, _bridge)
|
||||||
|
|
||||||
#
|
#
|
||||||
# END IN-BAND SIGNALLING
|
# END IN-BAND SIGNALLING
|
||||||
|