Route between TGs / |Reflectors on HBP systems

This commit is contained in:
Simon 2020-11-13 22:24:31 +00:00
parent 5e9e84614a
commit d076096faa

View File

@ -773,6 +773,146 @@ class routerOBP(OPENBRIDGE):
def __init__(self, _name, _config, _report): def __init__(self, _name, _config, _report):
OPENBRIDGE.__init__(self, _name, _config, _report) OPENBRIDGE.__init__(self, _name, _config, _report)
self.STATUS = {} self.STATUS = {}
def to_target(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _call_type, _frame_type, _dtype_vseq, _stream_id, _data, pkt_time, dmrpkt, _bits,_bridge,_system):
for _target in BRIDGES[_bridge]:
if (_target['SYSTEM'] != self._system) and (_target['ACTIVE']):
_target_status = systems[_target['SYSTEM']].STATUS
_target_system = self._CONFIG['SYSTEMS'][_target['SYSTEM']]
if _target_system['MODE'] == 'OPENBRIDGE':
# Is this a new call stream on the target?
if (_stream_id not in _target_status):
# This is a new call stream on the target
_target_status[_stream_id] = {
'START': pkt_time,
'CONTENTION':False,
'RFS': _rf_src,
'TGID': _dst_id,
}
# Generate LCs (full and EMB) for the TX stream
dst_lc = b''.join([self.STATUS[_stream_id]['LC'][0:3], _target['TGID'], _rf_src])
_target_status[_stream_id]['H_LC'] = bptc.encode_header_lc(dst_lc)
_target_status[_stream_id]['T_LC'] = bptc.encode_terminator_lc(dst_lc)
_target_status[_stream_id]['EMB_LC'] = bptc.encode_emblc(dst_lc)
logger.info('(%s) Conference Bridge: %s, Call Bridged to OBP System: %s TS: %s, TGID: %s', self._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
if CONFIG['REPORTS']['REPORT']:
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,START,TX,{},{},{},{},{},{}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID'])).encode(encoding='utf-8', errors='ignore'))
# Record the time of this packet so we can later identify a stale stream
_target_status[_stream_id]['LAST'] = pkt_time
# Clear the TS bit -- all OpenBridge streams are effectively on TS1
_tmp_bits = _bits & ~(1 << 7)
# Assemble transmit HBP packet header
_tmp_data = b''.join([_data[:8], _target['TGID'], _data[11:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
# MUST TEST FOR NEW STREAM AND IF SO, RE-WRITE THE LC FOR THE TARGET
# MUST RE-WRITE DESTINATION TGID IF DIFFERENT
# if _dst_id != rule['DST_GROUP']:
dmrbits = bitarray(endian='big')
dmrbits.frombytes(dmrpkt)
# Create a voice header packet (FULL LC)
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD:
dmrbits = _target_status[_stream_id]['H_LC'][0:98] + dmrbits[98:166] + _target_status[_stream_id]['H_LC'][98:197]
# Create a voice terminator packet (FULL LC)
elif _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VTERM:
dmrbits = _target_status[_stream_id]['T_LC'][0:98] + dmrbits[98:166] + _target_status[_stream_id]['T_LC'][98:197]
if CONFIG['REPORTS']['REPORT']:
call_duration = pkt_time - _target_status[_stream_id]['START']
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID']), call_duration).encode(encoding='utf-8', errors='ignore'))
# Create a Burst B-E packet (Embedded LC)
elif _dtype_vseq in [1,2,3,4]:
dmrbits = dmrbits[0:116] + _target_status[_stream_id]['EMB_LC'][_dtype_vseq] + dmrbits[148:264]
dmrpkt = dmrbits.tobytes()
_tmp_data = b''.join([_tmp_data, dmrpkt])
else:
# BEGIN CONTENTION HANDLING
#
# The rules for each of the 4 "ifs" below are listed here for readability. The Frame To Send is:
# From a different group than last RX from this HBSystem, but it has been less than Group Hangtime
# From a different group than last TX to this HBSystem, but it has been less than Group Hangtime
# From the same group as the last RX from this HBSystem, but from a different subscriber, and it has been less than stream timeout
# From the same group as the last TX to this HBSystem, but from a different subscriber, and it has been less than stream timeout
# The "continue" at the end of each means the next iteration of the for loop that tests for matching rules
#
if ((_target['TGID'] != _target_status[_target['TS']]['RX_TGID']) and ((pkt_time - _target_status[_target['TS']]['RX_TIME']) < _target_system['GROUP_HANGTIME'])):
if self.STATUS[_stream_id]['CONTENTION'] == False:
self.STATUS[_stream_id]['CONTENTION'] = True
logger.info('(%s) Call not routed to TGID %s, target active or in group hangtime: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_target['TGID']), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['RX_TGID']))
continue
if ((_target['TGID'] != _target_status[_target['TS']]['TX_TGID']) and ((pkt_time - _target_status[_target['TS']]['TX_TIME']) < _target_system['GROUP_HANGTIME'])):
if self.STATUS[_stream_id]['CONTENTION'] == False:
self.STATUS[_stream_id]['CONTENTION'] = True
logger.info('(%s) Call not routed to TGID%s, target in group hangtime: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_target['TGID']), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['TX_TGID']))
continue
if (_target['TGID'] == _target_status[_target['TS']]['RX_TGID']) and ((pkt_time - _target_status[_target['TS']]['RX_TIME']) < STREAM_TO):
if self.STATUS[_stream_id]['CONTENTION'] == False:
self.STATUS[_stream_id]['CONTENTION'] = True
logger.info('(%s) Call not routed to TGID%s, matching call already active on target: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_target['TGID']), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['RX_TGID']))
continue
if (_target['TGID'] == _target_status[_target['TS']]['TX_TGID']) and (_rf_src != _target_status[_target['TS']]['TX_RFS']) and ((pkt_time - _target_status[_target['TS']]['TX_TIME']) < STREAM_TO):
if self.STATUS[_stream_id]['CONTENTION'] == False:
self.STATUS[_stream_id]['CONTENTION'] = True
logger.info('(%s) Call not routed for subscriber %s, call route in progress on target: HBSystem: %s, TS: %s, TGID: %s, SUB: %s', self._system, int_id(_rf_src), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['TX_TGID']), int_id(_target_status[_target['TS']]['TX_RFS']))
continue
# Is this a new call stream?
if (_target_status[_target['TS']]['TX_STREAM_ID'] != _stream_id):
# Record the DST TGID and Stream ID
_target_status[_target['TS']]['TX_START'] = pkt_time
_target_status[_target['TS']]['TX_TGID'] = _target['TGID']
_target_status[_target['TS']]['TX_STREAM_ID'] = _stream_id
_target_status[_target['TS']]['TX_RFS'] = _rf_src
_target_status[_target['TS']]['TX_PEER'] = _peer_id
# Generate LCs (full and EMB) for the TX stream
dst_lc = b''.join([self.STATUS[_stream_id]['LC'][0:3], _target['TGID'], _rf_src])
_target_status[_target['TS']]['TX_H_LC'] = bptc.encode_header_lc(dst_lc)
_target_status[_target['TS']]['TX_T_LC'] = bptc.encode_terminator_lc(dst_lc)
_target_status[_target['TS']]['TX_EMB_LC'] = bptc.encode_emblc(dst_lc)
logger.debug('(%s) Generating TX FULL and EMB LCs for HomeBrew destination: System: %s, TS: %s, TGID: %s', self._system, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
logger.info('(%s) Conference Bridge: %s, Call Bridged to HBP System: %s TS: %s, TGID: %s', self._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
if CONFIG['REPORTS']['REPORT']:
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,START,TX,{},{},{},{},{},{}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID'])).encode(encoding='utf-8', errors='ignore'))
# Set other values for the contention handler to test next time there is a frame to forward
_target_status[_target['TS']]['TX_TIME'] = pkt_time
_target_status[_target['TS']]['TX_TYPE'] = _dtype_vseq
# Handle any necessary re-writes for the destination
if _system['TS'] != _target['TS']:
_tmp_bits = _bits ^ 1 << 7
else:
_tmp_bits = _bits
# Assemble transmit HBP packet header
_tmp_data = b''.join([_data[:8], _target['TGID'], _data[11:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
# MUST TEST FOR NEW STREAM AND IF SO, RE-WRITE THE LC FOR THE TARGET
# MUST RE-WRITE DESTINATION TGID IF DIFFERENT
# if _dst_id != rule['DST_GROUP']:
dmrbits = bitarray(endian='big')
dmrbits.frombytes(dmrpkt)
# Create a voice header packet (FULL LC)
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD:
dmrbits = _target_status[_target['TS']]['TX_H_LC'][0:98] + dmrbits[98:166] + _target_status[_target['TS']]['TX_H_LC'][98:197]
# Create a voice terminator packet (FULL LC)
elif _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VTERM:
dmrbits = _target_status[_target['TS']]['TX_T_LC'][0:98] + dmrbits[98:166] + _target_status[_target['TS']]['TX_T_LC'][98:197]
if CONFIG['REPORTS']['REPORT']:
call_duration = pkt_time - _target_status[_target['TS']]['TX_START']
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID']), call_duration).encode(encoding='utf-8', errors='ignore'))
# Create a Burst B-E packet (Embedded LC)
elif _dtype_vseq in [1,2,3,4]:
dmrbits = dmrbits[0:116] + _target_status[_target['TS']]['TX_EMB_LC'][_dtype_vseq] + dmrbits[148:264]
dmrpkt = dmrbits.tobytes()
_tmp_data = b''.join([_tmp_data, dmrpkt, b'\x00\x00']) # Add two bytes of nothing since OBP doesn't include BER & RSSI bytes #_data[53:55]
# Transmit the packet to the destination system
systems[_target['SYSTEM']].send_system(_tmp_data)
#logger.debug('(%s) Packet routed by bridge: %s to system: %s TS: %s, TGID: %s', self._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
def dmrd_received(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _call_type, _frame_type, _dtype_vseq, _stream_id, _data): def dmrd_received(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _call_type, _frame_type, _dtype_vseq, _stream_id, _data):
@ -815,144 +955,15 @@ class routerOBP(OPENBRIDGE):
if (_system['SYSTEM'] == self._system and _system['TGID'] == _dst_id and _system['TS'] == _slot and _system['ACTIVE'] == True): if (_system['SYSTEM'] == self._system and _system['TGID'] == _dst_id and _system['TS'] == _slot and _system['ACTIVE'] == True):
for _target in BRIDGES[_bridge]: self.to_target(_peer_id, _rf_src, _dst_id, _seq, _slot, _call_type, _frame_type, _dtype_vseq, _stream_id, _data, pkt_time, dmrpkt, _bits,_bridge,_system)
if (_target['SYSTEM'] != self._system) and (_target['ACTIVE']):
_target_status = systems[_target['SYSTEM']].STATUS #Send to reflector or TG too, if it exists
_target_system = self._CONFIG['SYSTEMS'][_target['SYSTEM']] if _bridge[0:1] == '#':
if _target_system['MODE'] == 'OPENBRIDGE': _bridge = _bridge[1:]
# Is this a new call stream on the target? else:
if (_stream_id not in _target_status): _bridge = '#'+_bridge
# This is a new call stream on the target if _bridge in BRIDGES:
_target_status[_stream_id] = { self.to_target(_peer_id, _rf_src, _dst_id, _seq, _slot, _call_type, _frame_type, _dtype_vseq, _stream_id, _data, pkt_time, dmrpkt, _bits,_bridge,_system)
'START': pkt_time,
'CONTENTION':False,
'RFS': _rf_src,
'TGID': _dst_id,
}
# Generate LCs (full and EMB) for the TX stream
dst_lc = b''.join([self.STATUS[_stream_id]['LC'][0:3], _target['TGID'], _rf_src])
_target_status[_stream_id]['H_LC'] = bptc.encode_header_lc(dst_lc)
_target_status[_stream_id]['T_LC'] = bptc.encode_terminator_lc(dst_lc)
_target_status[_stream_id]['EMB_LC'] = bptc.encode_emblc(dst_lc)
logger.info('(%s) Conference Bridge: %s, Call Bridged to OBP System: %s TS: %s, TGID: %s', self._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
if CONFIG['REPORTS']['REPORT']:
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,START,TX,{},{},{},{},{},{}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID'])).encode(encoding='utf-8', errors='ignore'))
# Record the time of this packet so we can later identify a stale stream
_target_status[_stream_id]['LAST'] = pkt_time
# Clear the TS bit -- all OpenBridge streams are effectively on TS1
_tmp_bits = _bits & ~(1 << 7)
# Assemble transmit HBP packet header
_tmp_data = b''.join([_data[:8], _target['TGID'], _data[11:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
# MUST TEST FOR NEW STREAM AND IF SO, RE-WRITE THE LC FOR THE TARGET
# MUST RE-WRITE DESTINATION TGID IF DIFFERENT
# if _dst_id != rule['DST_GROUP']:
dmrbits = bitarray(endian='big')
dmrbits.frombytes(dmrpkt)
# Create a voice header packet (FULL LC)
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD:
dmrbits = _target_status[_stream_id]['H_LC'][0:98] + dmrbits[98:166] + _target_status[_stream_id]['H_LC'][98:197]
# Create a voice terminator packet (FULL LC)
elif _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VTERM:
dmrbits = _target_status[_stream_id]['T_LC'][0:98] + dmrbits[98:166] + _target_status[_stream_id]['T_LC'][98:197]
if CONFIG['REPORTS']['REPORT']:
call_duration = pkt_time - _target_status[_stream_id]['START']
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID']), call_duration).encode(encoding='utf-8', errors='ignore'))
# Create a Burst B-E packet (Embedded LC)
elif _dtype_vseq in [1,2,3,4]:
dmrbits = dmrbits[0:116] + _target_status[_stream_id]['EMB_LC'][_dtype_vseq] + dmrbits[148:264]
dmrpkt = dmrbits.tobytes()
_tmp_data = b''.join([_tmp_data, dmrpkt])
else:
# BEGIN CONTENTION HANDLING
#
# The rules for each of the 4 "ifs" below are listed here for readability. The Frame To Send is:
# From a different group than last RX from this HBSystem, but it has been less than Group Hangtime
# From a different group than last TX to this HBSystem, but it has been less than Group Hangtime
# From the same group as the last RX from this HBSystem, but from a different subscriber, and it has been less than stream timeout
# From the same group as the last TX to this HBSystem, but from a different subscriber, and it has been less than stream timeout
# The "continue" at the end of each means the next iteration of the for loop that tests for matching rules
#
if ((_target['TGID'] != _target_status[_target['TS']]['RX_TGID']) and ((pkt_time - _target_status[_target['TS']]['RX_TIME']) < _target_system['GROUP_HANGTIME'])):
if self.STATUS[_stream_id]['CONTENTION'] == False:
self.STATUS[_stream_id]['CONTENTION'] = True
logger.info('(%s) Call not routed to TGID %s, target active or in group hangtime: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_target['TGID']), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['RX_TGID']))
continue
if ((_target['TGID'] != _target_status[_target['TS']]['TX_TGID']) and ((pkt_time - _target_status[_target['TS']]['TX_TIME']) < _target_system['GROUP_HANGTIME'])):
if self.STATUS[_stream_id]['CONTENTION'] == False:
self.STATUS[_stream_id]['CONTENTION'] = True
logger.info('(%s) Call not routed to TGID%s, target in group hangtime: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_target['TGID']), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['TX_TGID']))
continue
if (_target['TGID'] == _target_status[_target['TS']]['RX_TGID']) and ((pkt_time - _target_status[_target['TS']]['RX_TIME']) < STREAM_TO):
if self.STATUS[_stream_id]['CONTENTION'] == False:
self.STATUS[_stream_id]['CONTENTION'] = True
logger.info('(%s) Call not routed to TGID%s, matching call already active on target: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_target['TGID']), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['RX_TGID']))
continue
if (_target['TGID'] == _target_status[_target['TS']]['TX_TGID']) and (_rf_src != _target_status[_target['TS']]['TX_RFS']) and ((pkt_time - _target_status[_target['TS']]['TX_TIME']) < STREAM_TO):
if self.STATUS[_stream_id]['CONTENTION'] == False:
self.STATUS[_stream_id]['CONTENTION'] = True
logger.info('(%s) Call not routed for subscriber %s, call route in progress on target: HBSystem: %s, TS: %s, TGID: %s, SUB: %s', self._system, int_id(_rf_src), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['TX_TGID']), int_id(_target_status[_target['TS']]['TX_RFS']))
continue
# Is this a new call stream?
if (_target_status[_target['TS']]['TX_STREAM_ID'] != _stream_id):
# Record the DST TGID and Stream ID
_target_status[_target['TS']]['TX_START'] = pkt_time
_target_status[_target['TS']]['TX_TGID'] = _target['TGID']
_target_status[_target['TS']]['TX_STREAM_ID'] = _stream_id
_target_status[_target['TS']]['TX_RFS'] = _rf_src
_target_status[_target['TS']]['TX_PEER'] = _peer_id
# Generate LCs (full and EMB) for the TX stream
dst_lc = b''.join([self.STATUS[_stream_id]['LC'][0:3], _target['TGID'], _rf_src])
_target_status[_target['TS']]['TX_H_LC'] = bptc.encode_header_lc(dst_lc)
_target_status[_target['TS']]['TX_T_LC'] = bptc.encode_terminator_lc(dst_lc)
_target_status[_target['TS']]['TX_EMB_LC'] = bptc.encode_emblc(dst_lc)
logger.debug('(%s) Generating TX FULL and EMB LCs for HomeBrew destination: System: %s, TS: %s, TGID: %s', self._system, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
logger.info('(%s) Conference Bridge: %s, Call Bridged to HBP System: %s TS: %s, TGID: %s', self._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
if CONFIG['REPORTS']['REPORT']:
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,START,TX,{},{},{},{},{},{}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID'])).encode(encoding='utf-8', errors='ignore'))
# Set other values for the contention handler to test next time there is a frame to forward
_target_status[_target['TS']]['TX_TIME'] = pkt_time
_target_status[_target['TS']]['TX_TYPE'] = _dtype_vseq
# Handle any necessary re-writes for the destination
if _system['TS'] != _target['TS']:
_tmp_bits = _bits ^ 1 << 7
else:
_tmp_bits = _bits
# Assemble transmit HBP packet header
_tmp_data = b''.join([_data[:8], _target['TGID'], _data[11:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
# MUST TEST FOR NEW STREAM AND IF SO, RE-WRITE THE LC FOR THE TARGET
# MUST RE-WRITE DESTINATION TGID IF DIFFERENT
# if _dst_id != rule['DST_GROUP']:
dmrbits = bitarray(endian='big')
dmrbits.frombytes(dmrpkt)
# Create a voice header packet (FULL LC)
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD:
dmrbits = _target_status[_target['TS']]['TX_H_LC'][0:98] + dmrbits[98:166] + _target_status[_target['TS']]['TX_H_LC'][98:197]
# Create a voice terminator packet (FULL LC)
elif _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VTERM:
dmrbits = _target_status[_target['TS']]['TX_T_LC'][0:98] + dmrbits[98:166] + _target_status[_target['TS']]['TX_T_LC'][98:197]
if CONFIG['REPORTS']['REPORT']:
call_duration = pkt_time - _target_status[_target['TS']]['TX_START']
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID']), call_duration).encode(encoding='utf-8', errors='ignore'))
# Create a Burst B-E packet (Embedded LC)
elif _dtype_vseq in [1,2,3,4]:
dmrbits = dmrbits[0:116] + _target_status[_target['TS']]['TX_EMB_LC'][_dtype_vseq] + dmrbits[148:264]
dmrpkt = dmrbits.tobytes()
_tmp_data = b''.join([_tmp_data, dmrpkt, b'\x00\x00']) # Add two bytes of nothing since OBP doesn't include BER & RSSI bytes #_data[53:55]
# Transmit the packet to the destination system
systems[_target['SYSTEM']].send_system(_tmp_data)
#logger.debug('(%s) Packet routed by bridge: %s to system: %s TS: %s, TGID: %s', self._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
# Final actions - Is this a voice terminator? # Final actions - Is this a voice terminator?
@ -1029,6 +1040,146 @@ class routerHBP(HBSYSTEM):
} }
} }
def to_target(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _call_type, _frame_type, _dtype_vseq, _stream_id, _data, pkt_time, dmrpkt, _bits,_bridge,_system):
for _target in BRIDGES[_bridge]:
if _target['SYSTEM'] != self._system:
if _target['ACTIVE']:
_target_status = systems[_target['SYSTEM']].STATUS
_target_system = self._CONFIG['SYSTEMS'][_target['SYSTEM']]
if _target_system['MODE'] == 'OPENBRIDGE':
# Is this a new call stream on the target?
if (_stream_id not in _target_status):
# This is a new call stream on the target
_target_status[_stream_id] = {
'START': pkt_time,
'CONTENTION':False,
'RFS': _rf_src,
'TGID': _dst_id,
}
# Generate LCs (full and EMB) for the TX stream
dst_lc = b''.join([self.STATUS[_slot]['RX_LC'][0:3], _target['TGID'], _rf_src])
_target_status[_stream_id]['H_LC'] = bptc.encode_header_lc(dst_lc)
_target_status[_stream_id]['T_LC'] = bptc.encode_terminator_lc(dst_lc)
_target_status[_stream_id]['EMB_LC'] = bptc.encode_emblc(dst_lc)
logger.info('(%s) Conference Bridge: %s, Call Bridged to OBP System: %s TS: %s, TGID: %s', self._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
if CONFIG['REPORTS']['REPORT']:
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,START,TX,{},{},{},{},{},{}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID'])).encode(encoding='utf-8', errors='ignore'))
# Record the time of this packet so we can later identify a stale stream
_target_status[_stream_id]['LAST'] = pkt_time
# Clear the TS bit -- all OpenBridge streams are effectively on TS1
_tmp_bits = _bits & ~(1 << 7)
# Assemble transmit HBP packet header
_tmp_data = b''.join([_data[:8], _target['TGID'], _data[11:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
# MUST TEST FOR NEW STREAM AND IF SO, RE-WRITE THE LC FOR THE TARGET
# MUST RE-WRITE DESTINATION TGID IF DIFFERENT
# if _dst_id != rule['DST_GROUP']:
dmrbits = bitarray(endian='big')
dmrbits.frombytes(dmrpkt)
# Create a voice header packet (FULL LC)
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD:
dmrbits = _target_status[_stream_id]['H_LC'][0:98] + dmrbits[98:166] + _target_status[_stream_id]['H_LC'][98:197]
# Create a voice terminator packet (FULL LC)
elif _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VTERM:
dmrbits = _target_status[_stream_id]['T_LC'][0:98] + dmrbits[98:166] + _target_status[_stream_id]['T_LC'][98:197]
if CONFIG['REPORTS']['REPORT']:
call_duration = pkt_time - _target_status[_stream_id]['START']
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID']), call_duration).encode(encoding='utf-8', errors='ignore'))
# Create a Burst B-E packet (Embedded LC)
elif _dtype_vseq in [1,2,3,4]:
dmrbits = dmrbits[0:116] + _target_status[_stream_id]['EMB_LC'][_dtype_vseq] + dmrbits[148:264]
dmrpkt = dmrbits.tobytes()
_tmp_data = b''.join([_tmp_data, dmrpkt])
else:
# BEGIN STANDARD CONTENTION HANDLING
#
# The rules for each of the 4 "ifs" below are listed here for readability. The Frame To Send is:
# From a different group than last RX from this HBSystem, but it has been less than Group Hangtime
# From a different group than last TX to this HBSystem, but it has been less than Group Hangtime
# From the same group as the last RX from this HBSystem, but from a different subscriber, and it has been less than stream timeout
# From the same group as the last TX to this HBSystem, but from a different subscriber, and it has been less than stream timeout
# The "continue" at the end of each means the next iteration of the for loop that tests for matching rules
#
if ((_target['TGID'] != _target_status[_target['TS']]['RX_TGID']) and ((pkt_time - _target_status[_target['TS']]['RX_TIME']) < _target_system['GROUP_HANGTIME'])):
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD and self.STATUS[_slot]['RX_STREAM_ID'] != _stream_id:
logger.info('(%s) Call not routed to TGID %s, target active or in group hangtime: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_target['TGID']), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['RX_TGID']))
continue
if ((_target['TGID'] != _target_status[_target['TS']]['TX_TGID']) and ((pkt_time - _target_status[_target['TS']]['TX_TIME']) < _target_system['GROUP_HANGTIME'])):
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD and self.STATUS[_slot]['RX_STREAM_ID'] != _stream_id:
logger.info('(%s) Call not routed to TGID%s, target in group hangtime: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_target['TGID']), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['TX_TGID']))
continue
if (_target['TGID'] == _target_status[_target['TS']]['RX_TGID']) and ((pkt_time - _target_status[_target['TS']]['RX_TIME']) < STREAM_TO):
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD and self.STATUS[_slot]['RX_STREAM_ID'] != _stream_id:
logger.info('(%s) Call not routed to TGID%s, matching call already active on target: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_target['TGID']), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['RX_TGID']))
continue
if (_target['TGID'] == _target_status[_target['TS']]['TX_TGID']) and (_rf_src != _target_status[_target['TS']]['TX_RFS']) and ((pkt_time - _target_status[_target['TS']]['TX_TIME']) < STREAM_TO):
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD and self.STATUS[_slot]['RX_STREAM_ID'] != _stream_id:
logger.info('(%s) Call not routed for subscriber %s, call route in progress on target: HBSystem: %s, TS: %s, TGID: %s, SUB: %s', self._system, int_id(_rf_src), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['TX_TGID']), int_id(_target_status[_target['TS']]['TX_RFS']))
continue
# Is this a new call stream?
if (_stream_id != self.STATUS[_slot]['RX_STREAM_ID']):
# Record the DST TGID and Stream ID
_target_status[_target['TS']]['TX_START'] = pkt_time
_target_status[_target['TS']]['TX_TGID'] = _target['TGID']
_target_status[_target['TS']]['TX_STREAM_ID'] = _stream_id
_target_status[_target['TS']]['TX_RFS'] = _rf_src
_target_status[_target['TS']]['TX_PEER'] = _peer_id
# Generate LCs (full and EMB) for the TX stream
dst_lc = self.STATUS[_slot]['RX_LC'][0:3] + _target['TGID'] + _rf_src
_target_status[_target['TS']]['TX_H_LC'] = bptc.encode_header_lc(dst_lc)
_target_status[_target['TS']]['TX_T_LC'] = bptc.encode_terminator_lc(dst_lc)
_target_status[_target['TS']]['TX_EMB_LC'] = bptc.encode_emblc(dst_lc)
logger.debug('(%s) Generating TX FULL and EMB LCs for HomeBrew destination: System: %s, TS: %s, TGID: %s', self._system, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
logger.info('(%s) Conference Bridge: %s, Call Bridged to HBP System: %s TS: %s, TGID: %s', self._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
if CONFIG['REPORTS']['REPORT']:
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,START,TX,{},{},{},{},{},{}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID'])).encode(encoding='utf-8', errors='ignore'))
# Set other values for the contention handler to test next time there is a frame to forward
_target_status[_target['TS']]['TX_TIME'] = pkt_time
_target_status[_target['TS']]['TX_TYPE'] = _dtype_vseq
# Handle any necessary re-writes for the destination
if _system['TS'] != _target['TS']:
_tmp_bits = _bits ^ 1 << 7
else:
_tmp_bits = _bits
# Assemble transmit HBP packet header
_tmp_data = b''.join([_data[:8], _target['TGID'], _data[11:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
# MUST TEST FOR NEW STREAM AND IF SO, RE-WRITE THE LC FOR THE TARGET
# MUST RE-WRITE DESTINATION TGID IF DIFFERENT
# if _dst_id != rule['DST_GROUP']:
dmrbits = bitarray(endian='big')
dmrbits.frombytes(dmrpkt)
# Create a voice header packet (FULL LC)
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD:
dmrbits = _target_status[_target['TS']]['TX_H_LC'][0:98] + dmrbits[98:166] + _target_status[_target['TS']]['TX_H_LC'][98:197]
# Create a voice terminator packet (FULL LC)
elif _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VTERM:
dmrbits = _target_status[_target['TS']]['TX_T_LC'][0:98] + dmrbits[98:166] + _target_status[_target['TS']]['TX_T_LC'][98:197]
if CONFIG['REPORTS']['REPORT']:
call_duration = pkt_time - _target_status[_target['TS']]['TX_START']
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID']), call_duration).encode(encoding='utf-8', errors='ignore'))
# Create a Burst B-E packet (Embedded LC)
elif _dtype_vseq in [1,2,3,4]:
dmrbits = dmrbits[0:116] + _target_status[_target['TS']]['TX_EMB_LC'][_dtype_vseq] + dmrbits[148:264]
dmrpkt = dmrbits.tobytes()
_tmp_data = b''.join([_tmp_data, dmrpkt, _data[53:55]])
# Transmit the packet to the destination system
systems[_target['SYSTEM']].send_system(_tmp_data)
#logger.debug('(%s) Packet routed by bridge: %s to system: %s TS: %s, TGID: %s', self._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
def dmrd_received(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _call_type, _frame_type, _dtype_vseq, _stream_id, _data): def dmrd_received(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _call_type, _frame_type, _dtype_vseq, _stream_id, _data):
pkt_time = time() pkt_time = time()
dmrpkt = _data[20:53] dmrpkt = _data[20:53]
@ -1210,143 +1361,15 @@ class routerHBP(HBSYSTEM):
if (_system['SYSTEM'] == self._system and _system['TGID'] == _dst_id and _system['TS'] == _slot and _system['ACTIVE'] == True): if (_system['SYSTEM'] == self._system and _system['TGID'] == _dst_id and _system['TS'] == _slot and _system['ACTIVE'] == True):
for _target in BRIDGES[_bridge]: self.to_target(_peer_id, _rf_src, _dst_id, _seq, _slot, _call_type, _frame_type, _dtype_vseq, _stream_id, _data, pkt_time, dmrpkt, _bits,_bridge,_system)
if _target['SYSTEM'] != self._system:
if _target['ACTIVE']: #Send to reflector or TG too, if it exists
_target_status = systems[_target['SYSTEM']].STATUS if _bridge[0:1] == '#':
_target_system = self._CONFIG['SYSTEMS'][_target['SYSTEM']] _bridge = _bridge[1:]
else:
if _target_system['MODE'] == 'OPENBRIDGE': _bridge = '#'+_bridge
# Is this a new call stream on the target? if _bridge in BRIDGES:
if (_stream_id not in _target_status): self.to_target(_peer_id, _rf_src, _dst_id, _seq, _slot, _call_type, _frame_type, _dtype_vseq, _stream_id, _data, pkt_time, dmrpkt, _bits,_bridge,_system)
# This is a new call stream on the target
_target_status[_stream_id] = {
'START': pkt_time,
'CONTENTION':False,
'RFS': _rf_src,
'TGID': _dst_id,
}
# Generate LCs (full and EMB) for the TX stream
dst_lc = b''.join([self.STATUS[_slot]['RX_LC'][0:3], _target['TGID'], _rf_src])
_target_status[_stream_id]['H_LC'] = bptc.encode_header_lc(dst_lc)
_target_status[_stream_id]['T_LC'] = bptc.encode_terminator_lc(dst_lc)
_target_status[_stream_id]['EMB_LC'] = bptc.encode_emblc(dst_lc)
logger.info('(%s) Conference Bridge: %s, Call Bridged to OBP System: %s TS: %s, TGID: %s', self._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
if CONFIG['REPORTS']['REPORT']:
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,START,TX,{},{},{},{},{},{}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID'])).encode(encoding='utf-8', errors='ignore'))
# Record the time of this packet so we can later identify a stale stream
_target_status[_stream_id]['LAST'] = pkt_time
# Clear the TS bit -- all OpenBridge streams are effectively on TS1
_tmp_bits = _bits & ~(1 << 7)
# Assemble transmit HBP packet header
_tmp_data = b''.join([_data[:8], _target['TGID'], _data[11:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
# MUST TEST FOR NEW STREAM AND IF SO, RE-WRITE THE LC FOR THE TARGET
# MUST RE-WRITE DESTINATION TGID IF DIFFERENT
# if _dst_id != rule['DST_GROUP']:
dmrbits = bitarray(endian='big')
dmrbits.frombytes(dmrpkt)
# Create a voice header packet (FULL LC)
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD:
dmrbits = _target_status[_stream_id]['H_LC'][0:98] + dmrbits[98:166] + _target_status[_stream_id]['H_LC'][98:197]
# Create a voice terminator packet (FULL LC)
elif _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VTERM:
dmrbits = _target_status[_stream_id]['T_LC'][0:98] + dmrbits[98:166] + _target_status[_stream_id]['T_LC'][98:197]
if CONFIG['REPORTS']['REPORT']:
call_duration = pkt_time - _target_status[_stream_id]['START']
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID']), call_duration).encode(encoding='utf-8', errors='ignore'))
# Create a Burst B-E packet (Embedded LC)
elif _dtype_vseq in [1,2,3,4]:
dmrbits = dmrbits[0:116] + _target_status[_stream_id]['EMB_LC'][_dtype_vseq] + dmrbits[148:264]
dmrpkt = dmrbits.tobytes()
_tmp_data = b''.join([_tmp_data, dmrpkt])
else:
# BEGIN STANDARD CONTENTION HANDLING
#
# The rules for each of the 4 "ifs" below are listed here for readability. The Frame To Send is:
# From a different group than last RX from this HBSystem, but it has been less than Group Hangtime
# From a different group than last TX to this HBSystem, but it has been less than Group Hangtime
# From the same group as the last RX from this HBSystem, but from a different subscriber, and it has been less than stream timeout
# From the same group as the last TX to this HBSystem, but from a different subscriber, and it has been less than stream timeout
# The "continue" at the end of each means the next iteration of the for loop that tests for matching rules
#
if ((_target['TGID'] != _target_status[_target['TS']]['RX_TGID']) and ((pkt_time - _target_status[_target['TS']]['RX_TIME']) < _target_system['GROUP_HANGTIME'])):
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD and self.STATUS[_slot]['RX_STREAM_ID'] != _stream_id:
logger.info('(%s) Call not routed to TGID %s, target active or in group hangtime: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_target['TGID']), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['RX_TGID']))
continue
if ((_target['TGID'] != _target_status[_target['TS']]['TX_TGID']) and ((pkt_time - _target_status[_target['TS']]['TX_TIME']) < _target_system['GROUP_HANGTIME'])):
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD and self.STATUS[_slot]['RX_STREAM_ID'] != _stream_id:
logger.info('(%s) Call not routed to TGID%s, target in group hangtime: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_target['TGID']), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['TX_TGID']))
continue
if (_target['TGID'] == _target_status[_target['TS']]['RX_TGID']) and ((pkt_time - _target_status[_target['TS']]['RX_TIME']) < STREAM_TO):
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD and self.STATUS[_slot]['RX_STREAM_ID'] != _stream_id:
logger.info('(%s) Call not routed to TGID%s, matching call already active on target: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_target['TGID']), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['RX_TGID']))
continue
if (_target['TGID'] == _target_status[_target['TS']]['TX_TGID']) and (_rf_src != _target_status[_target['TS']]['TX_RFS']) and ((pkt_time - _target_status[_target['TS']]['TX_TIME']) < STREAM_TO):
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD and self.STATUS[_slot]['RX_STREAM_ID'] != _stream_id:
logger.info('(%s) Call not routed for subscriber %s, call route in progress on target: HBSystem: %s, TS: %s, TGID: %s, SUB: %s', self._system, int_id(_rf_src), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['TX_TGID']), int_id(_target_status[_target['TS']]['TX_RFS']))
continue
# Is this a new call stream?
if (_stream_id != self.STATUS[_slot]['RX_STREAM_ID']):
# Record the DST TGID and Stream ID
_target_status[_target['TS']]['TX_START'] = pkt_time
_target_status[_target['TS']]['TX_TGID'] = _target['TGID']
_target_status[_target['TS']]['TX_STREAM_ID'] = _stream_id
_target_status[_target['TS']]['TX_RFS'] = _rf_src
_target_status[_target['TS']]['TX_PEER'] = _peer_id
# Generate LCs (full and EMB) for the TX stream
dst_lc = self.STATUS[_slot]['RX_LC'][0:3] + _target['TGID'] + _rf_src
_target_status[_target['TS']]['TX_H_LC'] = bptc.encode_header_lc(dst_lc)
_target_status[_target['TS']]['TX_T_LC'] = bptc.encode_terminator_lc(dst_lc)
_target_status[_target['TS']]['TX_EMB_LC'] = bptc.encode_emblc(dst_lc)
logger.debug('(%s) Generating TX FULL and EMB LCs for HomeBrew destination: System: %s, TS: %s, TGID: %s', self._system, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
logger.info('(%s) Conference Bridge: %s, Call Bridged to HBP System: %s TS: %s, TGID: %s', self._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
if CONFIG['REPORTS']['REPORT']:
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,START,TX,{},{},{},{},{},{}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID'])).encode(encoding='utf-8', errors='ignore'))
# Set other values for the contention handler to test next time there is a frame to forward
_target_status[_target['TS']]['TX_TIME'] = pkt_time
_target_status[_target['TS']]['TX_TYPE'] = _dtype_vseq
# Handle any necessary re-writes for the destination
if _system['TS'] != _target['TS']:
_tmp_bits = _bits ^ 1 << 7
else:
_tmp_bits = _bits
# Assemble transmit HBP packet header
_tmp_data = b''.join([_data[:8], _target['TGID'], _data[11:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
# MUST TEST FOR NEW STREAM AND IF SO, RE-WRITE THE LC FOR THE TARGET
# MUST RE-WRITE DESTINATION TGID IF DIFFERENT
# if _dst_id != rule['DST_GROUP']:
dmrbits = bitarray(endian='big')
dmrbits.frombytes(dmrpkt)
# Create a voice header packet (FULL LC)
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD:
dmrbits = _target_status[_target['TS']]['TX_H_LC'][0:98] + dmrbits[98:166] + _target_status[_target['TS']]['TX_H_LC'][98:197]
# Create a voice terminator packet (FULL LC)
elif _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VTERM:
dmrbits = _target_status[_target['TS']]['TX_T_LC'][0:98] + dmrbits[98:166] + _target_status[_target['TS']]['TX_T_LC'][98:197]
if CONFIG['REPORTS']['REPORT']:
call_duration = pkt_time - _target_status[_target['TS']]['TX_START']
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID']), call_duration).encode(encoding='utf-8', errors='ignore'))
# Create a Burst B-E packet (Embedded LC)
elif _dtype_vseq in [1,2,3,4]:
dmrbits = dmrbits[0:116] + _target_status[_target['TS']]['TX_EMB_LC'][_dtype_vseq] + dmrbits[148:264]
dmrpkt = dmrbits.tobytes()
_tmp_data = b''.join([_tmp_data, dmrpkt, _data[53:55]])
# Transmit the packet to the destination system
systems[_target['SYSTEM']].send_system(_tmp_data)
#logger.debug('(%s) Packet routed by bridge: %s to system: %s TS: %s, TGID: %s', self._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
# Final actions - Is this a voice terminator? # Final actions - Is this a voice terminator?