1175 lines
78 KiB
Python
Executable File
1175 lines
78 KiB
Python
Executable File
#!/usr/bin/env python
|
|
#
|
|
###############################################################################
|
|
# Copyright (C) 2016-2019 Cortney T. Buffington, N0MJS <n0mjs@me.com>
|
|
#
|
|
# This program is free software; you can redistribute it and/or modify
|
|
# it under the terms of the GNU General Public License as published by
|
|
# the Free Software Foundation; either version 3 of the License, or
|
|
# (at your option) any later version.
|
|
#
|
|
# This program is distributed in the hope that it will be useful,
|
|
# but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
# GNU General Public License for more details.
|
|
#
|
|
# You should have received a copy of the GNU General Public License
|
|
# along with this program; if not, write to the Free Software Foundation,
|
|
# Inc., 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301 USA
|
|
###############################################################################
|
|
|
|
'''
|
|
This application, in conjuction with it's rule file (rules.py) will
|
|
work like a "conference bridge". This is similar to what most hams think of as a
|
|
reflector. You define conference bridges and any system joined to that conference
|
|
bridge will both receive traffic from, and send traffic to any other system
|
|
joined to the same conference bridge. It does not provide end-to-end connectivity
|
|
as each end system must individually be joined to a conference bridge (a name
|
|
you create in the configuraiton file) to pass traffic.
|
|
|
|
This program currently only works with group voice calls.
|
|
'''
|
|
|
|
# Python modules we need
|
|
import sys
|
|
from bitarray import bitarray
|
|
from time import time
|
|
import importlib.util
|
|
|
|
# Twisted is pretty important, so I keep it separate
|
|
from twisted.internet.protocol import Factory, Protocol
|
|
from twisted.protocols.basic import NetstringReceiver
|
|
from twisted.internet import reactor, task
|
|
|
|
# Things we import from the main hblink module
|
|
from hblink import HBSYSTEM, OPENBRIDGE, systems, hblink_handler, reportFactory, REPORT_OPCODES, mk_aliases
|
|
from dmr_utils3.utils import bytes_3, int_id, get_alias
|
|
from dmr_utils3 import decode, bptc, const
|
|
import config
|
|
import log
|
|
from const import *
|
|
|
|
# Stuff for socket reporting
|
|
import pickle
|
|
# REMOVE LATER from datetime import datetime
|
|
# The module needs logging, but handlers, etc. are controlled by the parent
|
|
import logging
|
|
logger = logging.getLogger(__name__)
|
|
|
|
|
|
# Does anybody read this stuff? There's a PEP somewhere that says I should do this.
|
|
__author__ = 'Cortney T. Buffington, N0MJS'
|
|
__copyright__ = 'Copyright (c) 2016-2019 Cortney T. Buffington, N0MJS and the K0USY Group'
|
|
__credits__ = 'Colin Durbridge, G4EML, Steve Zingman, N4IRS; Mike Zingman, N4IRR; Jonathan Naylor, G4KLX; Hans Barthen, DL5DI; Torsten Shultze, DG1HT'
|
|
__license__ = 'GNU GPLv3'
|
|
__maintainer__ = 'Cort Buffington, N0MJS'
|
|
__email__ = 'n0mjs@me.com'
|
|
|
|
# Module gobal varaibles
|
|
|
|
# Dictionary for dynamically mapping unit (subscriber) to a system.
|
|
# This is for pruning unit-to-uint calls to not broadcast once the
|
|
# target system for a unit is identified
|
|
# format 'unit_id': ('SYSTEM', time)
|
|
UNIT_MAP = {}
|
|
|
|
|
|
# Timed loop used for reporting HBP status
|
|
#
|
|
# REPORT BASED ON THE TYPE SELECTED IN THE MAIN CONFIG FILE
|
|
def config_reports(_config, _factory):
|
|
if True: #_config['REPORTS']['REPORT']:
|
|
def reporting_loop(logger, _server):
|
|
logger.debug('(REPORT) Periodic reporting loop started')
|
|
_server.send_config()
|
|
_server.send_bridge()
|
|
|
|
logger.info('(REPORT) HBlink TCP reporting server configured')
|
|
|
|
report_server = _factory(_config)
|
|
report_server.clients = []
|
|
reactor.listenTCP(_config['REPORTS']['REPORT_PORT'], report_server)
|
|
|
|
reporting = task.LoopingCall(reporting_loop, logger, report_server)
|
|
reporting.start(_config['REPORTS']['REPORT_INTERVAL'])
|
|
|
|
return report_server
|
|
|
|
|
|
# Import Bridging rules
|
|
# Note: A stanza *must* exist for any MASTER or CLIENT configured in the main
|
|
# configuration file and listed as "active". It can be empty,
|
|
# but it has to exist.
|
|
def make_bridges(_rules):
|
|
# Convert integer GROUP ID numbers from the config into hex strings
|
|
# we need to send in the actual data packets.
|
|
for _bridge in _rules:
|
|
for _system in _rules[_bridge]:
|
|
if _system['SYSTEM'] not in CONFIG['SYSTEMS']:
|
|
sys.exit('ERROR: Conference bridge "{}" references a system named "{}" that is not enabled in the main configuration'.format(_bridge, _system['SYSTEM']))
|
|
|
|
_system['TGID'] = bytes_3(_system['TGID'])
|
|
for i, e in enumerate(_system['ON']):
|
|
_system['ON'][i] = bytes_3(_system['ON'][i])
|
|
for i, e in enumerate(_system['OFF']):
|
|
_system['OFF'][i] = bytes_3(_system['OFF'][i])
|
|
_system['TIMEOUT'] = _system['TIMEOUT']*60
|
|
if _system['ACTIVE'] == True:
|
|
_system['TIMER'] = time() + _system['TIMEOUT']
|
|
else:
|
|
_system['TIMER'] = time()
|
|
return _rules
|
|
|
|
|
|
# Run this every minute for rule timer updates
|
|
def rule_timer_loop():
|
|
global UNIT_MAP
|
|
logger.debug('(ROUTER) routerHBP Rule timer loop started')
|
|
_now = time()
|
|
|
|
for _bridge in BRIDGES:
|
|
for _system in BRIDGES[_bridge]:
|
|
if _system['TO_TYPE'] == 'ON':
|
|
if _system['ACTIVE'] == True:
|
|
if _system['TIMER'] < _now:
|
|
_system['ACTIVE'] = False
|
|
logger.info('(ROUTER) Conference Bridge TIMEOUT: DEACTIVATE System: %s, Bridge: %s, TS: %s, TGID: %s', _system['SYSTEM'], _bridge, _system['TS'], int_id(_system['TGID']))
|
|
else:
|
|
timeout_in = _system['TIMER'] - _now
|
|
logger.info('(ROUTER) Conference Bridge ACTIVE (ON timer running): System: %s Bridge: %s, TS: %s, TGID: %s, Timeout in: %.2fs,', _system['SYSTEM'], _bridge, _system['TS'], int_id(_system['TGID']), timeout_in)
|
|
elif _system['ACTIVE'] == False:
|
|
logger.debug('(ROUTER) Conference Bridge INACTIVE (no change): System: %s Bridge: %s, TS: %s, TGID: %s', _system['SYSTEM'], _bridge, _system['TS'], int_id(_system['TGID']))
|
|
elif _system['TO_TYPE'] == 'OFF':
|
|
if _system['ACTIVE'] == False:
|
|
if _system['TIMER'] < _now:
|
|
_system['ACTIVE'] = True
|
|
logger.info('(ROUTER) Conference Bridge TIMEOUT: ACTIVATE System: %s, Bridge: %s, TS: %s, TGID: %s', _system['SYSTEM'], _bridge, _system['TS'], int_id(_system['TGID']))
|
|
else:
|
|
timeout_in = _system['TIMER'] - _now
|
|
logger.info('(ROUTER) Conference Bridge INACTIVE (OFF timer running): System: %s Bridge: %s, TS: %s, TGID: %s, Timeout in: %.2fs,', _system['SYSTEM'], _bridge, _system['TS'], int_id(_system['TGID']), timeout_in)
|
|
elif _system['ACTIVE'] == True:
|
|
logger.debug('(ROUTER) Conference Bridge ACTIVE (no change): System: %s Bridge: %s, TS: %s, TGID: %s', _system['SYSTEM'], _bridge, _system['TS'], int_id(_system['TGID']))
|
|
else:
|
|
logger.debug('(ROUTER) Conference Bridge NO ACTION: System: %s, Bridge: %s, TS: %s, TGID: %s', _system['SYSTEM'], _bridge, _system['TS'], int_id(_system['TGID']))
|
|
|
|
_then = _now - 60
|
|
remove_list = []
|
|
for unit in UNIT_MAP:
|
|
if UNIT_MAP[unit][1] < (_then):
|
|
remove_list.append(unit)
|
|
|
|
for unit in remove_list:
|
|
del UNIT_MAP[unit]
|
|
|
|
logger.debug('Removed unit(s) %s from UNIT_MAP', remove_list)
|
|
|
|
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
report_server.send_clients(b'bridge updated')
|
|
|
|
|
|
# run this every 10 seconds to trim orphaned stream ids
|
|
def stream_trimmer_loop():
|
|
logger.debug('(ROUTER) Trimming inactive stream IDs from system lists')
|
|
_now = time()
|
|
|
|
for system in systems:
|
|
# HBP systems, master and peer
|
|
if CONFIG['SYSTEMS'][system]['MODE'] != 'OPENBRIDGE':
|
|
for slot in range(1,3):
|
|
_slot = systems[system].STATUS[slot]
|
|
|
|
# RX slot check
|
|
if _slot['RX_TYPE'] != HBPF_SLT_VTERM and _slot['RX_TIME'] < _now - 5:
|
|
_slot['RX_TYPE'] = HBPF_SLT_VTERM
|
|
logger.info('(%s) *TIME OUT* RX STREAM ID: %s SUB: %s TGID %s, TS %s, Duration: %.2f', \
|
|
system, int_id(_slot['RX_STREAM_ID']), int_id(_slot['RX_RFS']), int_id(_slot['RX_TGID']), slot, _slot['RX_TIME'] - _slot['RX_START'])
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
systems[system]._report.send_bridgeEvent('GROUP VOICE,END,RX,{},{},{},{},{},{},{:.2f}'.format(system, int_id(_slot['RX_STREAM_ID']), int_id(_slot['RX_PEER']), int_id(_slot['RX_RFS']), slot, int_id(_slot['RX_TGID']), _slot['RX_TIME'] - _slot['RX_START']).encode(encoding='utf-8', errors='ignore'))
|
|
|
|
# TX slot check
|
|
if _slot['TX_TYPE'] != HBPF_SLT_VTERM and _slot['TX_TIME'] < _now - 5:
|
|
_slot['TX_TYPE'] = HBPF_SLT_VTERM
|
|
logger.info('(%s) *TIME OUT* TX STREAM ID: %s SUB: %s TGID %s, TS %s, Duration: %.2f', \
|
|
system, int_id(_slot['TX_STREAM_ID']), int_id(_slot['TX_RFS']), int_id(_slot['TX_TGID']), slot, _slot['TX_TIME'] - _slot['TX_START'])
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
systems[system]._report.send_bridgeEvent('GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}'.format(system, int_id(_slot['TX_STREAM_ID']), int_id(_slot['TX_PEER']), int_id(_slot['TX_RFS']), slot, int_id(_slot['TX_TGID']), _slot['TX_TIME'] - _slot['TX_START']).encode(encoding='utf-8', errors='ignore'))
|
|
|
|
# OBP systems
|
|
# We can't delete items from a dicationry that's being iterated, so we have to make a temporarly list of entrys to remove later
|
|
if CONFIG['SYSTEMS'][system]['MODE'] == 'OPENBRIDGE':
|
|
remove_list = []
|
|
for stream_id in systems[system].STATUS:
|
|
if systems[system].STATUS[stream_id]['LAST'] < _now - 5:
|
|
remove_list.append(stream_id)
|
|
for stream_id in remove_list:
|
|
if stream_id in systems[system].STATUS:
|
|
_stream = systems[system].STATUS[stream_id]
|
|
_sysconfig = CONFIG['SYSTEMS'][system]
|
|
if systems[system].STATUS[stream_id]['ACTIVE']:
|
|
logger.info('(%s) *TIME OUT* STREAM ID: %s SUB: %s PEER: %s TYPE: %s DST ID: %s TS 1 Duration: %.2f', \
|
|
system, int_id(stream_id), get_alias(int_id(_stream['RFS']), subscriber_ids), get_alias(int_id(_sysconfig['NETWORK_ID']), peer_ids), _stream['TYPE'], get_alias(int_id(_stream['DST']), talkgroup_ids), _stream['LAST'] - _stream['START'])
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
if _stream['TYPE'] == 'GROUP':
|
|
systems[system]._report.send_bridgeEvent('GROUP VOICE,END,RX,{},{},{},{},{},{},{:.2f}'.format(system, int_id(stream_id), int_id(_sysconfig['NETWORK_ID']), int_id(_stream['RFS']), 1, int_id(_stream['DST']), _stream['LAST'] - _stream['START']).encode(encoding='utf-8', errors='ignore'))
|
|
elif _stream['TYPE'] == 'UNIT':
|
|
systems[system]._report.send_bridgeEvent('UNIT VOICE,END,RX,{},{},{},{},{},{},{:.2f}'.format(system, int_id(stream_id), int_id(_sysconfig['NETWORK_ID']), int_id(_stream['RFS']), 1, int_id(_stream['DST']), _stream['LAST'] - _stream['START']).encode(encoding='utf-8', errors='ignore'))
|
|
removed = systems[system].STATUS.pop(stream_id)
|
|
else:
|
|
logger.error('(%s) Attemped to remove OpenBridge Stream ID %s not in the Stream ID list: %s', system, int_id(stream_id), [id for id in systems[system].STATUS])
|
|
|
|
class routerOBP(OPENBRIDGE):
|
|
|
|
def __init__(self, _name, _config, _report):
|
|
OPENBRIDGE.__init__(self, _name, _config, _report)
|
|
self.name = _name
|
|
self.STATUS = {}
|
|
|
|
# list of self._targets for unit (subscriber, private) calls
|
|
self._targets = []
|
|
|
|
def group_received(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _frame_type, _dtype_vseq, _stream_id, _data):
|
|
pkt_time = time()
|
|
dmrpkt = _data[20:53]
|
|
_bits = _data[15]
|
|
|
|
# Is this a new call stream?
|
|
if (_stream_id not in self.STATUS):
|
|
# This is a new call stream
|
|
self.STATUS[_stream_id] = {
|
|
'START': pkt_time,
|
|
'CONTENTION':False,
|
|
'RFS': _rf_src,
|
|
'TYPE': 'GROUP',
|
|
'DST': _dst_id,
|
|
'ACTIVE': True
|
|
}
|
|
|
|
# If we can, use the LC from the voice header as to keep all options intact
|
|
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD:
|
|
decoded = decode.voice_head_term(dmrpkt)
|
|
self.STATUS[_stream_id]['LC'] = decoded['LC']
|
|
|
|
# If we don't have a voice header then don't wait to decode the Embedded LC
|
|
# just make a new one from the HBP header. This is good enough, and it saves lots of time
|
|
else:
|
|
self.STATUS[_stream_id]['LC'] = LC_OPT + _dst_id + _rf_src
|
|
|
|
|
|
logger.info('(%s) *GROUP CALL START* OBP STREAM ID: %s SUB: %s (%s) PEER: %s (%s) TGID %s (%s), TS %s', \
|
|
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot)
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
self._report.send_bridgeEvent('GROUP VOICE,START,RX,{},{},{},{},{},{}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id)).encode(encoding='utf-8', errors='ignore'))
|
|
|
|
self.STATUS[_stream_id]['LAST'] = pkt_time
|
|
|
|
|
|
for _bridge in BRIDGES:
|
|
for _system in BRIDGES[_bridge]:
|
|
|
|
if (_system['SYSTEM'] == self._system and _system['TGID'] == _dst_id and _system['TS'] == _slot and _system['ACTIVE'] == True):
|
|
|
|
for _target in BRIDGES[_bridge]:
|
|
if (_target['SYSTEM'] != self._system) and (_target['ACTIVE']):
|
|
_target_status = systems[_target['SYSTEM']].STATUS
|
|
_target_system = self._CONFIG['SYSTEMS'][_target['SYSTEM']]
|
|
if _target_system['MODE'] == 'OPENBRIDGE':
|
|
# Is this a new call stream on the target?
|
|
if (_stream_id not in _target_status):
|
|
# This is a new call stream on the target
|
|
_target_status[_stream_id] = {
|
|
'START': pkt_time,
|
|
'CONTENTION':False,
|
|
'RFS': _rf_src,
|
|
'TYPE': 'GROUP',
|
|
'DST': _dst_id,
|
|
'ACTIVE': True
|
|
}
|
|
# Generate LCs (full and EMB) for the TX stream
|
|
dst_lc = b''.join([self.STATUS[_stream_id]['LC'][0:3], _target['TGID'], _rf_src])
|
|
_target_status[_stream_id]['H_LC'] = bptc.encode_header_lc(dst_lc)
|
|
_target_status[_stream_id]['T_LC'] = bptc.encode_terminator_lc(dst_lc)
|
|
_target_status[_stream_id]['EMB_LC'] = bptc.encode_emblc(dst_lc)
|
|
|
|
logger.info('(%s) Conference Bridge: %s, Call Bridged to OBP System: %s TS: %s, TGID: %s', self._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,START,TX,{},{},{},{},{},{}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID'])).encode(encoding='utf-8', errors='ignore'))
|
|
|
|
# Record the time of this packet so we can later identify a stale stream
|
|
_target_status[_stream_id]['LAST'] = pkt_time
|
|
# Clear the TS bit -- all OpenBridge streams are effectively on TS1
|
|
_tmp_bits = _bits & ~(1 << 7)
|
|
|
|
# Assemble transmit HBP packet header
|
|
_tmp_data = b''.join([_data[:8], _target['TGID'], _data[11:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
|
|
|
|
# MUST TEST FOR NEW STREAM AND IF SO, RE-WRITE THE LC FOR THE TARGET
|
|
# MUST RE-WRITE DESTINATION TGID IF DIFFERENT
|
|
# if _dst_id != rule['DST_GROUP']:
|
|
dmrbits = bitarray(endian='big')
|
|
dmrbits.frombytes(dmrpkt)
|
|
# Create a voice header packet (FULL LC)
|
|
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD:
|
|
dmrbits = _target_status[_stream_id]['H_LC'][0:98] + dmrbits[98:166] + _target_status[_stream_id]['H_LC'][98:197]
|
|
# Create a voice terminator packet (FULL LC)
|
|
elif _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VTERM:
|
|
dmrbits = _target_status[_stream_id]['T_LC'][0:98] + dmrbits[98:166] + _target_status[_stream_id]['T_LC'][98:197]
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
call_duration = pkt_time - _target_status[_stream_id]['START']
|
|
_target_status[_stream_id]['ACTIVE'] = False
|
|
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID']), call_duration).encode(encoding='utf-8', errors='ignore'))
|
|
# Create a Burst B-E packet (Embedded LC)
|
|
elif _dtype_vseq in [1,2,3,4]:
|
|
dmrbits = dmrbits[0:116] + _target_status[_stream_id]['EMB_LC'][_dtype_vseq] + dmrbits[148:264]
|
|
dmrpkt = dmrbits.tobytes()
|
|
_tmp_data = b''.join([_tmp_data, dmrpkt])
|
|
|
|
else:
|
|
# BEGIN CONTENTION HANDLING
|
|
#
|
|
# The rules for each of the 4 "ifs" below are listed here for readability. The Frame To Send is:
|
|
# From a different group than last RX from this HBSystem, but it has been less than Group Hangtime
|
|
# From a different group than last TX to this HBSystem, but it has been less than Group Hangtime
|
|
# From the same group as the last RX from this HBSystem, but from a different subscriber, and it has been less than stream timeout
|
|
# From the same group as the last TX to this HBSystem, but from a different subscriber, and it has been less than stream timeout
|
|
# The "continue" at the end of each means the next iteration of the for loop that tests for matching rules
|
|
#
|
|
if ((_target['TGID'] != _target_status[_target['TS']]['RX_TGID']) and ((pkt_time - _target_status[_target['TS']]['RX_TIME']) < _target_system['GROUP_HANGTIME'])):
|
|
if self.STATUS[_stream_id]['CONTENTION'] == False:
|
|
self.STATUS[_stream_id]['CONTENTION'] = True
|
|
logger.info('(%s) Call not routed to TGID %s, target active or in group hangtime: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_target['TGID']), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['RX_TGID']))
|
|
continue
|
|
if ((_target['TGID'] != _target_status[_target['TS']]['TX_TGID']) and ((pkt_time - _target_status[_target['TS']]['TX_TIME']) < _target_system['GROUP_HANGTIME'])):
|
|
if self.STATUS[_stream_id]['CONTENTION'] == False:
|
|
self.STATUS[_stream_id]['CONTENTION'] = True
|
|
logger.info('(%s) Call not routed to TGID%s, target in group hangtime: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_target['TGID']), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['TX_TGID']))
|
|
continue
|
|
if (_target['TGID'] == _target_status[_target['TS']]['RX_TGID']) and ((pkt_time - _target_status[_target['TS']]['RX_TIME']) < STREAM_TO):
|
|
if self.STATUS[_stream_id]['CONTENTION'] == False:
|
|
self.STATUS[_stream_id]['CONTENTION'] = True
|
|
logger.info('(%s) Call not routed to TGID%s, matching call already active on target: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_target['TGID']), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['RX_TGID']))
|
|
continue
|
|
if (_target['TGID'] == _target_status[_target['TS']]['TX_TGID']) and (_rf_src != _target_status[_target['TS']]['TX_RFS']) and ((pkt_time - _target_status[_target['TS']]['TX_TIME']) < STREAM_TO):
|
|
if self.STATUS[_stream_id]['CONTENTION'] == False:
|
|
self.STATUS[_stream_id]['CONTENTION'] = True
|
|
logger.info('(%s) Call not routed for subscriber %s, call route in progress on target: HBSystem: %s, TS: %s, TGID: %s, SUB: %s', self._system, int_id(_rf_src), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['TX_TGID']), int_id(_target_status[_target['TS']]['TX_RFS']))
|
|
continue
|
|
|
|
# Is this a new call stream?
|
|
if (_target_status[_target['TS']]['TX_STREAM_ID'] != _stream_id):
|
|
# Record the DST TGID and Stream ID
|
|
_target_status[_target['TS']]['TX_START'] = pkt_time
|
|
_target_status[_target['TS']]['TX_TGID'] = _target['TGID']
|
|
_target_status[_target['TS']]['TX_STREAM_ID'] = _stream_id
|
|
_target_status[_target['TS']]['TX_RFS'] = _rf_src
|
|
_target_status[_target['TS']]['TX_PEER'] = _peer_id
|
|
# Generate LCs (full and EMB) for the TX stream
|
|
dst_lc = b''.join([self.STATUS[_stream_id]['LC'][0:3], _target['TGID'], _rf_src])
|
|
_target_status[_target['TS']]['TX_H_LC'] = bptc.encode_header_lc(dst_lc)
|
|
_target_status[_target['TS']]['TX_T_LC'] = bptc.encode_terminator_lc(dst_lc)
|
|
_target_status[_target['TS']]['TX_EMB_LC'] = bptc.encode_emblc(dst_lc)
|
|
logger.debug('(%s) Generating TX FULL and EMB LCs for HomeBrew destination: System: %s, TS: %s, TGID: %s', self._system, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
|
|
logger.info('(%s) Conference Bridge: %s, Call Bridged to HBP System: %s TS: %s, TGID: %s', self._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,START,TX,{},{},{},{},{},{}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID'])).encode(encoding='utf-8', errors='ignore'))
|
|
|
|
# Set other values for the contention handler to test next time there is a frame to forward
|
|
_target_status[_target['TS']]['TX_TIME'] = pkt_time
|
|
_target_status[_target['TS']]['TX_TYPE'] = _dtype_vseq
|
|
|
|
# Handle any necessary re-writes for the destination
|
|
if _system['TS'] != _target['TS']:
|
|
_tmp_bits = _bits ^ 1 << 7
|
|
else:
|
|
_tmp_bits = _bits
|
|
|
|
# Assemble transmit HBP packet header
|
|
_tmp_data = b''.join([_data[:8], _target['TGID'], _data[11:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
|
|
|
|
# MUST TEST FOR NEW STREAM AND IF SO, RE-WRITE THE LC FOR THE TARGET
|
|
# MUST RE-WRITE DESTINATION TGID IF DIFFERENT
|
|
# if _dst_id != rule['DST_GROUP']:
|
|
dmrbits = bitarray(endian='big')
|
|
dmrbits.frombytes(dmrpkt)
|
|
# Create a voice header packet (FULL LC)
|
|
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD:
|
|
dmrbits = _target_status[_target['TS']]['TX_H_LC'][0:98] + dmrbits[98:166] + _target_status[_target['TS']]['TX_H_LC'][98:197]
|
|
# Create a voice terminator packet (FULL LC)
|
|
elif _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VTERM:
|
|
dmrbits = _target_status[_target['TS']]['TX_T_LC'][0:98] + dmrbits[98:166] + _target_status[_target['TS']]['TX_T_LC'][98:197]
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
call_duration = pkt_time - _target_status[_target['TS']]['TX_START']
|
|
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID']), call_duration).encode(encoding='utf-8', errors='ignore'))
|
|
# Create a Burst B-E packet (Embedded LC)
|
|
elif _dtype_vseq in [1,2,3,4]:
|
|
dmrbits = dmrbits[0:116] + _target_status[_target['TS']]['TX_EMB_LC'][_dtype_vseq] + dmrbits[148:264]
|
|
dmrpkt = dmrbits.tobytes()
|
|
_tmp_data = b''.join([_tmp_data, dmrpkt, b'\x00\x00']) # Add two bytes of nothing since OBP doesn't include BER & RSSI bytes #_data[53:55]
|
|
|
|
# Transmit the packet to the destination system
|
|
systems[_target['SYSTEM']].send_system(_tmp_data)
|
|
#logger.debug('(%s) Packet routed by bridge: %s to system: %s TS: %s, TGID: %s', self._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
|
|
|
|
|
|
# Final actions - Is this a voice terminator?
|
|
if (_frame_type == HBPF_DATA_SYNC) and (_dtype_vseq == HBPF_SLT_VTERM):
|
|
call_duration = pkt_time - self.STATUS[_stream_id]['START']
|
|
logger.info('(%s) *GROUP CALL END* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) TGID %s (%s), TS %s, Duration: %.2f', \
|
|
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot, call_duration)
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
self._report.send_bridgeEvent('GROUP VOICE,END,RX,{},{},{},{},{},{},{:.2f}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id), call_duration).encode(encoding='utf-8', errors='ignore'))
|
|
self.STATUS[_stream_id]['ACTIVE'] = False
|
|
logger.debug('(%s) OpenBridge sourced call stream end, remove terminated Stream ID: %s', self._system, int_id(_stream_id))
|
|
|
|
|
|
def unit_received(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _frame_type, _dtype_vseq, _stream_id, _data):
|
|
global UNIT_MAP
|
|
pkt_time = time()
|
|
dmrpkt = _data[20:53]
|
|
_bits = _data[15]
|
|
|
|
# Make/update this unit in the UNIT_MAP cache
|
|
UNIT_MAP[_rf_src] = (self.name, pkt_time)
|
|
|
|
|
|
# Is this a new call stream?
|
|
if (_stream_id not in self.STATUS):
|
|
# This is a new call stream
|
|
self.STATUS[_stream_id] = {
|
|
'START': pkt_time,
|
|
'CONTENTION':False,
|
|
'RFS': _rf_src,
|
|
'TYPE': 'UNIT',
|
|
'DST': _dst_id,
|
|
'ACTIVE': True
|
|
}
|
|
|
|
# Create a destination list for the call:
|
|
if _dst_id in UNIT_MAP:
|
|
if UNIT_MAP[_dst_id][0] != self._system:
|
|
self._targets = [UNIT_MAP[_dst_id][0]]
|
|
else:
|
|
self._targets = []
|
|
logger.error('UNIT call to a subscriber on the same system, send nothing')
|
|
else:
|
|
self._targets = list(UNIT)
|
|
self._targets.remove(self._system)
|
|
|
|
|
|
# This is a new call stream, so log & report
|
|
logger.info('(%s) *UNIT CALL START* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) UNIT: %s (%s), TS: %s, FORWARD: %s', \
|
|
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot, self._targets)
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
self._report.send_bridgeEvent('UNIT VOICE,START,RX,{},{},{},{},{},{},{}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id), self._targets).encode(encoding='utf-8', errors='ignore'))
|
|
|
|
# Record the time of this packet so we can later identify a stale stream
|
|
self.STATUS[_stream_id]['LAST'] = pkt_time
|
|
|
|
for _target in self._targets:
|
|
_target_status = systems[_target].STATUS
|
|
_target_system = self._CONFIG['SYSTEMS'][_target]
|
|
|
|
if self._CONFIG['SYSTEMS'][_target]['MODE'] == 'OPENBRIDGE':
|
|
if (_stream_id not in _target_status):
|
|
# This is a new call stream on the target
|
|
_target_status[_stream_id] = {
|
|
'START': pkt_time,
|
|
'CONTENTION':False,
|
|
'RFS': _rf_src,
|
|
'TYPE': 'UNIT',
|
|
'DST': _dst_id,
|
|
'ACTIVE': True
|
|
}
|
|
|
|
logger.info('(%s) Unit call bridged to OBP System: %s TS: %s, TGID: %s', self._system, _target, _slot if _target_system['BOTH_SLOTS'] else 1, int_id(_dst_id))
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
systems[_target]._report.send_bridgeEvent('UNIT VOICE,START,TX,{},{},{},{},{},{}'.format(_target, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id)).encode(encoding='utf-8', errors='ignore'))
|
|
|
|
# Record the time of this packet so we can later identify a stale stream
|
|
_target_status[_stream_id]['LAST'] = pkt_time
|
|
# Clear the TS bit and follow propper OBP definition, unless "BOTH_SLOTS" is set. This only works for unit calls.
|
|
if _target_system['BOTH_SLOTS']:
|
|
_tmp_bits = _bits
|
|
else:
|
|
_tmp_bits = _bits & ~(1 << 7)
|
|
|
|
# Assemble transmit HBP packet
|
|
_tmp_data = b''.join([_data[:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
|
|
_data = b''.join([_tmp_data, dmrpkt])
|
|
|
|
if (_frame_type == HBPF_DATA_SYNC) and (_dtype_vseq == HBPF_SLT_VTERM):
|
|
_target_status[_stream_id]['ACTIVE'] = False
|
|
|
|
else:
|
|
# BEGIN STANDARD CONTENTION HANDLING
|
|
#
|
|
# The rules for each of the 4 "ifs" below are listed here for readability. The Frame To Send is:
|
|
# From a different group than last RX from this HBSystem, but it has been less than Group Hangtime
|
|
# From a different group than last TX to this HBSystem, but it has been less than Group Hangtime
|
|
# From the same group as the last RX from this HBSystem, but from a different subscriber, and it has been less than stream timeout
|
|
# From the same group as the last TX to this HBSystem, but from a different subscriber, and it has been less than stream timeout
|
|
# The "continue" at the end of each means the next iteration of the for loop that tests for matching rules
|
|
#
|
|
'''
|
|
if ((_dst_id != _target_status[_slot]['RX_TGID']) and ((pkt_time - _target_status[_slot]['RX_TIME']) < _target_system['GROUP_HANGTIME'])):
|
|
if self.STATUS[_stream_id]['CONTENTION'] == False:
|
|
self.STATUS[_stream_id]['CONTENTION'] = True
|
|
logger.info('(%s) Call not routed to TGID %s, target active or in group hangtime: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_dst_id), _target, _slot, int_id(_target_status[_slot]['RX_TGID']))
|
|
continue
|
|
if ((_dst_id != _target_status[_slot]['TX_TGID']) and ((pkt_time - _target_status[_slot]['TX_TIME']) < _target_system['GROUP_HANGTIME'])):
|
|
if self.STATUS[_stream_id]['CONTENTION'] == False:
|
|
self.STATUS[_stream_id]['CONTENTION'] = True
|
|
logger.info('(%s) Call not routed to TGID%s, target in group hangtime: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_dst_id), _target, _slot, int_id(_target_status[_slot]['TX_TGID']))
|
|
continue
|
|
'''
|
|
if (_dst_id == _target_status[_slot]['RX_TGID']) and ((pkt_time - _target_status[_slot]['RX_TIME']) < STREAM_TO):
|
|
if self.STATUS[_stream_id]['CONTENTION'] == False:
|
|
self.STATUS[_stream_id]['CONTENTION'] = True
|
|
logger.info('(%s) Call not routed to TGID%s, matching call already active on target: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_dst_id), _target, _slot, int_id(_target_status[_slot]['RX_TGID']))
|
|
continue
|
|
if (_dst_id == _target_status[_slot]['TX_TGID']) and (_rf_src != _target_status[_slot]['TX_RFS']) and ((pkt_time - _target_status[_slot]['TX_TIME']) < STREAM_TO):
|
|
if self.STATUS[_stream_id]['CONTENTION'] == False:
|
|
self.STATUS[_stream_id]['CONTENTION'] = True
|
|
logger.info('(%s) Call not routed for subscriber %s, call route in progress on target: HBSystem: %s, TS: %s, TGID: %s, SUB: %s', self._system, int_id(_rf_src), _target, _slot, int_id(_target_status[_slot]['TX_TGID']), int_id(_target_status[_slot]['TX_RFS']))
|
|
continue
|
|
|
|
# Record target information if this is a new call stream?
|
|
if (_stream_id not in self.STATUS):
|
|
# Record the DST TGID and Stream ID
|
|
_target_status[_slot]['TX_START'] = pkt_time
|
|
_target_status[_slot]['TX_TGID'] = _dst_id
|
|
_target_status[_slot]['TX_STREAM_ID'] = _stream_id
|
|
_target_status[_slot]['TX_RFS'] = _rf_src
|
|
_target_status[_slot]['TX_PEER'] = _peer_id
|
|
|
|
logger.info('(%s) Unit call bridged to HBP System: %s TS: %s, UNIT: %s', self._system, _target, _slot, int_id(_dst_id))
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
systems[_target]._report.send_bridgeEvent('UNIT VOICE,START,TX,{},{},{},{},{},{}'.format(_target, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id)).encode(encoding='utf-8', errors='ignore'))
|
|
|
|
# Set other values for the contention handler to test next time there is a frame to forward
|
|
_target_status[_slot]['TX_TIME'] = pkt_time
|
|
_target_status[_slot]['TX_TYPE'] = _dtype_vseq
|
|
|
|
#send the call:
|
|
systems[_target].send_system(_data)
|
|
|
|
if _target_system['MODE'] == 'OPENBRIDGE':
|
|
if (_frame_type == HBPF_DATA_SYNC) and (_dtype_vseq == HBPF_SLT_VTERM):
|
|
if (_stream_id in _target_status):
|
|
_target_status.pop(_stream_id)
|
|
|
|
|
|
# Final actions - Is this a voice terminator?
|
|
if (_frame_type == HBPF_DATA_SYNC) and (_dtype_vseq == HBPF_SLT_VTERM):
|
|
self._targets = []
|
|
call_duration = pkt_time - self.STATUS[_stream_id]['START']
|
|
logger.info('(%s) *UNIT CALL END* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) UNIT %s (%s), TS %s, Duration: %.2f', \
|
|
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot, call_duration)
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
self._report.send_bridgeEvent('UNIT VOICE,END,RX,{},{},{},{},{},{},{:.2f}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id), call_duration).encode(encoding='utf-8', errors='ignore'))
|
|
|
|
|
|
def dmrd_received(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _call_type, _frame_type, _dtype_vseq, _stream_id, _data):
|
|
|
|
if _call_type == 'group':
|
|
self.group_received(_peer_id, _rf_src, _dst_id, _seq, _slot, _frame_type, _dtype_vseq, _stream_id, _data)
|
|
elif _call_type == 'unit':
|
|
self.unit_received(_peer_id, _rf_src, _dst_id, _seq, _slot, _frame_type, _dtype_vseq, _stream_id, _data)
|
|
elif _call_type == 'vscsbk':
|
|
logger.debug('CSBK recieved, but HBlink does not process them currently')
|
|
else:
|
|
logger.error('Unknown call type recieved -- not processed')
|
|
|
|
|
|
class routerHBP(HBSYSTEM):
|
|
|
|
def __init__(self, _name, _config, _report):
|
|
HBSYSTEM.__init__(self, _name, _config, _report)
|
|
self.name = _name
|
|
|
|
# list of self._targets for unit (subscriber, private) calls
|
|
self._targets = []
|
|
|
|
# Status information for the system, TS1 & TS2
|
|
# 1 & 2 are "timeslot"
|
|
# In TX_EMB_LC, 2-5 are burst B-E
|
|
self.STATUS = {
|
|
1: {
|
|
'RX_START': time(),
|
|
'TX_START': time(),
|
|
'RX_SEQ': 0,
|
|
'RX_RFS': b'\x00',
|
|
'TX_RFS': b'\x00',
|
|
'RX_PEER': b'\x00',
|
|
'TX_PEER': b'\x00',
|
|
'RX_STREAM_ID': b'\x00',
|
|
'TX_STREAM_ID': b'\x00',
|
|
'RX_TGID': b'\x00\x00\x00',
|
|
'TX_TGID': b'\x00\x00\x00',
|
|
'RX_TIME': time(),
|
|
'TX_TIME': time(),
|
|
'RX_TYPE': HBPF_SLT_VTERM,
|
|
'TX_TYPE': HBPF_SLT_VTERM,
|
|
'RX_LC': b'\x00',
|
|
'TX_H_LC': b'\x00',
|
|
'TX_T_LC': b'\x00',
|
|
'TX_EMB_LC': {
|
|
1: b'\x00',
|
|
2: b'\x00',
|
|
3: b'\x00',
|
|
4: b'\x00',
|
|
}
|
|
},
|
|
2: {
|
|
'RX_START': time(),
|
|
'TX_START': time(),
|
|
'RX_SEQ': 0,
|
|
'RX_RFS': b'\x00',
|
|
'TX_RFS': b'\x00',
|
|
'RX_PEER': b'\x00',
|
|
'TX_PEER': b'\x00',
|
|
'RX_STREAM_ID': b'\x00',
|
|
'TX_STREAM_ID': b'\x00',
|
|
'RX_TGID': b'\x00\x00\x00',
|
|
'TX_TGID': b'\x00\x00\x00',
|
|
'RX_TIME': time(),
|
|
'TX_TIME': time(),
|
|
'RX_TYPE': HBPF_SLT_VTERM,
|
|
'TX_TYPE': HBPF_SLT_VTERM,
|
|
'RX_LC': b'\x00',
|
|
'TX_H_LC': b'\x00',
|
|
'TX_T_LC': b'\x00',
|
|
'TX_EMB_LC': {
|
|
1: b'\x00',
|
|
2: b'\x00',
|
|
3: b'\x00',
|
|
4: b'\x00',
|
|
}
|
|
}
|
|
}
|
|
|
|
|
|
def group_received(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _frame_type, _dtype_vseq, _stream_id, _data):
|
|
global UNIT_MAP
|
|
pkt_time = time()
|
|
dmrpkt = _data[20:53]
|
|
_bits = _data[15]
|
|
|
|
# Make/update an entry in the UNIT_MAP for this subscriber
|
|
UNIT_MAP[_rf_src] = (self.name, pkt_time)
|
|
|
|
# Is this a new call stream?
|
|
if (_stream_id != self.STATUS[_slot]['RX_STREAM_ID']):
|
|
if (self.STATUS[_slot]['RX_TYPE'] != HBPF_SLT_VTERM) and (pkt_time < (self.STATUS[_slot]['RX_TIME'] + STREAM_TO)) and (_rf_src != self.STATUS[_slot]['RX_RFS']):
|
|
logger.warning('(%s) Packet received with STREAM ID: %s <FROM> SUB: %s PEER: %s <TO> TGID %s, SLOT %s collided with existing call', self._system, int_id(_stream_id), int_id(_rf_src), int_id(_peer_id), int_id(_dst_id), _slot)
|
|
return
|
|
|
|
# This is a new call stream
|
|
self.STATUS[_slot]['RX_START'] = pkt_time
|
|
logger.info('(%s) *GROUP CALL START* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) TGID %s (%s), TS %s', \
|
|
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot)
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
self._report.send_bridgeEvent('GROUP VOICE,START,RX,{},{},{},{},{},{}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id)).encode(encoding='utf-8', errors='ignore'))
|
|
|
|
# If we can, use the LC from the voice header as to keep all options intact
|
|
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD:
|
|
decoded = decode.voice_head_term(dmrpkt)
|
|
self.STATUS[_slot]['RX_LC'] = decoded['LC']
|
|
|
|
# If we don't have a voice header then don't wait to decode it from the Embedded LC
|
|
# just make a new one from the HBP header. This is good enough, and it saves lots of time
|
|
else:
|
|
self.STATUS[_slot]['RX_LC'] = LC_OPT + _dst_id + _rf_src
|
|
|
|
for _bridge in BRIDGES:
|
|
for _system in BRIDGES[_bridge]:
|
|
|
|
if (_system['SYSTEM'] == self._system and _system['TGID'] == _dst_id and _system['TS'] == _slot and _system['ACTIVE'] == True):
|
|
|
|
for _target in BRIDGES[_bridge]:
|
|
if _target['SYSTEM'] != self._system:
|
|
if _target['ACTIVE']:
|
|
_target_status = systems[_target['SYSTEM']].STATUS
|
|
_target_system = self._CONFIG['SYSTEMS'][_target['SYSTEM']]
|
|
|
|
if _target_system['MODE'] == 'OPENBRIDGE':
|
|
# Is this a new call stream on the target?
|
|
if (_stream_id not in _target_status):
|
|
# This is a new call stream on the target
|
|
_target_status[_stream_id] = {
|
|
'START': pkt_time,
|
|
'CONTENTION':False,
|
|
'RFS': _rf_src,
|
|
'TYPE': 'GROUP',
|
|
'DST': _dst_id,
|
|
'ACTIVE': True,
|
|
}
|
|
# Generate LCs (full and EMB) for the TX stream
|
|
dst_lc = b''.join([self.STATUS[_slot]['RX_LC'][0:3], _target['TGID'], _rf_src])
|
|
_target_status[_stream_id]['H_LC'] = bptc.encode_header_lc(dst_lc)
|
|
_target_status[_stream_id]['T_LC'] = bptc.encode_terminator_lc(dst_lc)
|
|
_target_status[_stream_id]['EMB_LC'] = bptc.encode_emblc(dst_lc)
|
|
|
|
logger.info('(%s) Conference Bridge: %s, Call Bridged to OBP System: %s TS: %s, TGID: %s', self._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,START,TX,{},{},{},{},{},{}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID'])).encode(encoding='utf-8', errors='ignore'))
|
|
|
|
# Record the time of this packet so we can later identify a stale stream
|
|
_target_status[_stream_id]['LAST'] = pkt_time
|
|
# Clear the TS bit -- all OpenBridge streams are effectively on TS1
|
|
_tmp_bits = _bits & ~(1 << 7)
|
|
|
|
# Assemble transmit HBP packet header
|
|
_tmp_data = b''.join([_data[:8], _target['TGID'], _data[11:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
|
|
|
|
# MUST TEST FOR NEW STREAM AND IF SO, RE-WRITE THE LC FOR THE TARGET
|
|
# MUST RE-WRITE DESTINATION TGID IF DIFFERENT
|
|
# if _dst_id != rule['DST_GROUP']:
|
|
dmrbits = bitarray(endian='big')
|
|
dmrbits.frombytes(dmrpkt)
|
|
# Create a voice header packet (FULL LC)
|
|
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD:
|
|
dmrbits = _target_status[_stream_id]['H_LC'][0:98] + dmrbits[98:166] + _target_status[_stream_id]['H_LC'][98:197]
|
|
# Create a voice terminator packet (FULL LC)
|
|
elif _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VTERM:
|
|
dmrbits = _target_status[_stream_id]['T_LC'][0:98] + dmrbits[98:166] + _target_status[_stream_id]['T_LC'][98:197]
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
call_duration = pkt_time - _target_status[_stream_id]['START']
|
|
_target_status[_stream_id]['ACTIVE'] = False
|
|
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID']), call_duration).encode(encoding='utf-8', errors='ignore'))
|
|
# Create a Burst B-E packet (Embedded LC)
|
|
elif _dtype_vseq in [1,2,3,4]:
|
|
dmrbits = dmrbits[0:116] + _target_status[_stream_id]['EMB_LC'][_dtype_vseq] + dmrbits[148:264]
|
|
dmrpkt = dmrbits.tobytes()
|
|
_tmp_data = b''.join([_tmp_data, dmrpkt])
|
|
|
|
else:
|
|
# BEGIN STANDARD CONTENTION HANDLING
|
|
#
|
|
# The rules for each of the 4 "ifs" below are listed here for readability. The Frame To Send is:
|
|
# From a different group than last RX from this HBSystem, but it has been less than Group Hangtime
|
|
# From a different group than last TX to this HBSystem, but it has been less than Group Hangtime
|
|
# From the same group as the last RX from this HBSystem, but from a different subscriber, and it has been less than stream timeout
|
|
# From the same group as the last TX to this HBSystem, but from a different subscriber, and it has been less than stream timeout
|
|
# The "continue" at the end of each means the next iteration of the for loop that tests for matching rules
|
|
#
|
|
if ((_target['TGID'] != _target_status[_target['TS']]['RX_TGID']) and ((pkt_time - _target_status[_target['TS']]['RX_TIME']) < _target_system['GROUP_HANGTIME'])):
|
|
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD and self.STATUS[_slot]['RX_STREAM_ID'] != _stream_id:
|
|
logger.info('(%s) Call not routed to TGID %s, target active or in group hangtime: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_target['TGID']), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['RX_TGID']))
|
|
continue
|
|
if ((_target['TGID'] != _target_status[_target['TS']]['TX_TGID']) and ((pkt_time - _target_status[_target['TS']]['TX_TIME']) < _target_system['GROUP_HANGTIME'])):
|
|
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD and self.STATUS[_slot]['RX_STREAM_ID'] != _stream_id:
|
|
logger.info('(%s) Call not routed to TGID%s, target in group hangtime: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_target['TGID']), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['TX_TGID']))
|
|
continue
|
|
if (_target['TGID'] == _target_status[_target['TS']]['RX_TGID']) and ((pkt_time - _target_status[_target['TS']]['RX_TIME']) < STREAM_TO):
|
|
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD and self.STATUS[_slot]['RX_STREAM_ID'] != _stream_id:
|
|
logger.info('(%s) Call not routed to TGID%s, matching call already active on target: HBSystem: %s, TS: %s, TGID: %s', self._system, int_id(_target['TGID']), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['RX_TGID']))
|
|
continue
|
|
if (_target['TGID'] == _target_status[_target['TS']]['TX_TGID']) and (_rf_src != _target_status[_target['TS']]['TX_RFS']) and ((pkt_time - _target_status[_target['TS']]['TX_TIME']) < STREAM_TO):
|
|
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD and self.STATUS[_slot]['RX_STREAM_ID'] != _stream_id:
|
|
logger.info('(%s) Call not routed for subscriber %s, call route in progress on target: HBSystem: %s, TS: %s, TGID: %s, SUB: %s', self._system, int_id(_rf_src), _target['SYSTEM'], _target['TS'], int_id(_target_status[_target['TS']]['TX_TGID']), int_id(_target_status[_target['TS']]['TX_RFS']))
|
|
continue
|
|
|
|
# Is this a new call stream?
|
|
if (_stream_id != self.STATUS[_slot]['RX_STREAM_ID']):
|
|
# Record the DST TGID and Stream ID
|
|
_target_status[_target['TS']]['TX_START'] = pkt_time
|
|
_target_status[_target['TS']]['TX_TGID'] = _target['TGID']
|
|
_target_status[_target['TS']]['TX_STREAM_ID'] = _stream_id
|
|
_target_status[_target['TS']]['TX_RFS'] = _rf_src
|
|
_target_status[_target['TS']]['TX_PEER'] = _peer_id
|
|
# Generate LCs (full and EMB) for the TX stream
|
|
dst_lc = self.STATUS[_slot]['RX_LC'][0:3] + _target['TGID'] + _rf_src
|
|
_target_status[_target['TS']]['TX_H_LC'] = bptc.encode_header_lc(dst_lc)
|
|
_target_status[_target['TS']]['TX_T_LC'] = bptc.encode_terminator_lc(dst_lc)
|
|
_target_status[_target['TS']]['TX_EMB_LC'] = bptc.encode_emblc(dst_lc)
|
|
logger.debug('(%s) Generating TX FULL and EMB LCs for HomeBrew destination: System: %s, TS: %s, TGID: %s', self._system, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
|
|
logger.info('(%s) Conference Bridge: %s, Call Bridged to HBP System: %s TS: %s, TGID: %s', self._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,START,TX,{},{},{},{},{},{}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID'])).encode(encoding='utf-8', errors='ignore'))
|
|
|
|
# Set other values for the contention handler to test next time there is a frame to forward
|
|
_target_status[_target['TS']]['TX_TIME'] = pkt_time
|
|
_target_status[_target['TS']]['TX_TYPE'] = _dtype_vseq
|
|
|
|
# Handle any necessary re-writes for the destination
|
|
if _system['TS'] != _target['TS']:
|
|
_tmp_bits = _bits ^ 1 << 7
|
|
else:
|
|
_tmp_bits = _bits
|
|
|
|
# Assemble transmit HBP packet header
|
|
_tmp_data = b''.join([_data[:8], _target['TGID'], _data[11:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
|
|
|
|
dmrbits = bitarray(endian='big')
|
|
dmrbits.frombytes(dmrpkt)
|
|
# Create a voice header packet (FULL LC)
|
|
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD:
|
|
dmrbits = _target_status[_target['TS']]['TX_H_LC'][0:98] + dmrbits[98:166] + _target_status[_target['TS']]['TX_H_LC'][98:197]
|
|
# Create a voice terminator packet (FULL LC)
|
|
elif _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VTERM:
|
|
dmrbits = _target_status[_target['TS']]['TX_T_LC'][0:98] + dmrbits[98:166] + _target_status[_target['TS']]['TX_T_LC'][98:197]
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
call_duration = pkt_time - _target_status[_target['TS']]['TX_START']
|
|
systems[_target['SYSTEM']]._report.send_bridgeEvent('GROUP VOICE,END,TX,{},{},{},{},{},{},{:.2f}'.format(_target['SYSTEM'], int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _target['TS'], int_id(_target['TGID']), call_duration).encode(encoding='utf-8', errors='ignore'))
|
|
# Create a Burst B-E packet (Embedded LC)
|
|
elif _dtype_vseq in [1,2,3,4]:
|
|
dmrbits = dmrbits[0:116] + _target_status[_target['TS']]['TX_EMB_LC'][_dtype_vseq] + dmrbits[148:264]
|
|
dmrpkt = dmrbits.tobytes()
|
|
_tmp_data = b''.join([_tmp_data, dmrpkt, _data[53:55]])
|
|
|
|
# Transmit the packet to the destination system
|
|
systems[_target['SYSTEM']].send_system(_tmp_data)
|
|
#logger.debug('(%s) Packet routed by bridge: %s to system: %s TS: %s, TGID: %s', self._system, _bridge, _target['SYSTEM'], _target['TS'], int_id(_target['TGID']))
|
|
|
|
if _target_system['MODE'] == 'OPENBRIDGE':
|
|
if (_frame_type == HBPF_DATA_SYNC) and (_dtype_vseq == HBPF_SLT_VTERM) and (self.STATUS[_slot]['RX_TYPE'] != HBPF_SLT_VTERM):
|
|
if (_stream_id in _target_status):
|
|
_target_status.pop(_stream_id)
|
|
|
|
|
|
# Final actions - Is this a voice terminator?
|
|
if (_frame_type == HBPF_DATA_SYNC) and (_dtype_vseq == HBPF_SLT_VTERM) and (self.STATUS[_slot]['RX_TYPE'] != HBPF_SLT_VTERM):
|
|
call_duration = pkt_time - self.STATUS[_slot]['RX_START']
|
|
logger.info('(%s) *GROUP CALL END* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) TGID %s (%s), TS %s, Duration: %.2f', \
|
|
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot, call_duration)
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
self._report.send_bridgeEvent('GROUP VOICE,END,RX,{},{},{},{},{},{},{:.2f}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id), call_duration).encode(encoding='utf-8', errors='ignore'))
|
|
|
|
#
|
|
# Begin in-band signalling for call end. This has nothign to do with routing traffic directly.
|
|
#
|
|
|
|
# Iterate the rules dictionary
|
|
|
|
for _bridge in BRIDGES:
|
|
for _system in BRIDGES[_bridge]:
|
|
if _system['SYSTEM'] == self._system:
|
|
|
|
# TGID matches a rule source, reset its timer
|
|
if _slot == _system['TS'] and _dst_id == _system['TGID'] and ((_system['TO_TYPE'] == 'ON' and (_system['ACTIVE'] == True)) or (_system['TO_TYPE'] == 'OFF' and _system['ACTIVE'] == False)):
|
|
_system['TIMER'] = pkt_time + _system['TIMEOUT']
|
|
logger.info('(%s) Transmission match for Bridge: %s. Reset timeout to %s', self._system, _bridge, _system['TIMER'])
|
|
|
|
# TGID matches an ACTIVATION trigger
|
|
if (_dst_id in _system['ON'] or _dst_id in _system['RESET']) and _slot == _system['TS']:
|
|
# Set the matching rule as ACTIVE
|
|
if _dst_id in _system['ON']:
|
|
if _system['ACTIVE'] == False:
|
|
_system['ACTIVE'] = True
|
|
_system['TIMER'] = pkt_time + _system['TIMEOUT']
|
|
logger.info('(%s) Bridge: %s, connection changed to state: %s', self._system, _bridge, _system['ACTIVE'])
|
|
# Cancel the timer if we've enabled an "OFF" type timeout
|
|
if _system['TO_TYPE'] == 'OFF':
|
|
_system['TIMER'] = pkt_time
|
|
logger.info('(%s) Bridge: %s set to "OFF" with an on timer rule: timeout timer cancelled', self._system, _bridge)
|
|
# Reset the timer for the rule
|
|
if _system['ACTIVE'] == True and _system['TO_TYPE'] == 'ON':
|
|
_system['TIMER'] = pkt_time + _system['TIMEOUT']
|
|
logger.info('(%s) Bridge: %s, timeout timer reset to: %s', self._system, _bridge, _system['TIMER'] - pkt_time)
|
|
|
|
# TGID matches an DE-ACTIVATION trigger
|
|
if (_dst_id in _system['OFF'] or _dst_id in _system['RESET']) and _slot == _system['TS']:
|
|
# Set the matching rule as ACTIVE
|
|
if _dst_id in _system['OFF']:
|
|
if _system['ACTIVE'] == True:
|
|
_system['ACTIVE'] = False
|
|
logger.info('(%s) Bridge: %s, connection changed to state: %s', self._system, _bridge, _system['ACTIVE'])
|
|
# Cancel the timer if we've enabled an "ON" type timeout
|
|
if _system['TO_TYPE'] == 'ON':
|
|
_system['TIMER'] = pkt_time
|
|
logger.info('(%s) Bridge: %s set to ON with and "OFF" timer rule: timeout timer cancelled', self._system, _bridge)
|
|
# Reset the timer for the rule
|
|
if _system['ACTIVE'] == False and _system['TO_TYPE'] == 'OFF':
|
|
_system['TIMER'] = pkt_time + _system['TIMEOUT']
|
|
logger.info('(%s) Bridge: %s, timeout timer reset to: %s', self._system, _bridge, _system['TIMER'] - pkt_time)
|
|
# Cancel the timer if we've enabled an "ON" type timeout
|
|
if _system['ACTIVE'] == True and _system['TO_TYPE'] == 'ON' and _dst_group in _system['OFF']:
|
|
_system['TIMER'] = pkt_time
|
|
logger.info('(%s) Bridge: %s set to ON with and "OFF" timer rule: timeout timer cancelled', self._system, _bridge)
|
|
|
|
#
|
|
# END IN-BAND SIGNALLING
|
|
#
|
|
# Mark status variables for use later
|
|
self.STATUS[_slot]['RX_PEER'] = _peer_id
|
|
self.STATUS[_slot]['RX_SEQ'] = _seq
|
|
self.STATUS[_slot]['RX_RFS'] = _rf_src
|
|
self.STATUS[_slot]['RX_TYPE'] = _dtype_vseq
|
|
self.STATUS[_slot]['RX_TGID'] = _dst_id
|
|
self.STATUS[_slot]['RX_TIME'] = pkt_time
|
|
self.STATUS[_slot]['RX_STREAM_ID'] = _stream_id
|
|
|
|
|
|
def unit_received(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _frame_type, _dtype_vseq, _stream_id, _data):
|
|
global UNIT_MAP
|
|
pkt_time = time()
|
|
dmrpkt = _data[20:53]
|
|
_bits = _data[15]
|
|
|
|
# Make/update this unit in the UNIT_MAP cache
|
|
UNIT_MAP[_rf_src] = (self.name, pkt_time)
|
|
|
|
|
|
# Is this a new call stream?
|
|
if (_stream_id != self.STATUS[_slot]['RX_STREAM_ID']):
|
|
|
|
# Collision in progress, bail out!
|
|
if (self.STATUS[_slot]['RX_TYPE'] != HBPF_SLT_VTERM) and (pkt_time < (self.STATUS[_slot]['RX_TIME'] + STREAM_TO)) and (_rf_src != self.STATUS[_slot]['RX_RFS']):
|
|
logger.warning('(%s) Packet received with STREAM ID: %s <FROM> SUB: %s PEER: %s <TO> UNIT %s, SLOT %s collided with existing call', self._system, int_id(_stream_id), int_id(_rf_src), int_id(_peer_id), int_id(_dst_id), _slot)
|
|
return
|
|
|
|
# Create a destination list for the call:
|
|
if _dst_id in UNIT_MAP:
|
|
if UNIT_MAP[_dst_id][0] != self._system:
|
|
self._targets = [UNIT_MAP[_dst_id][0]]
|
|
else:
|
|
self._targets = []
|
|
logger.error('UNIT call to a subscriber on the same system, send nothing')
|
|
else:
|
|
self._targets = list(UNIT)
|
|
self._targets.remove(self._system)
|
|
|
|
# This is a new call stream, so log & report
|
|
self.STATUS[_slot]['RX_START'] = pkt_time
|
|
logger.info('(%s) *UNIT CALL START* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) UNIT: %s (%s), TS: %s, FORWARD: %s', \
|
|
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot, self._targets)
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
self._report.send_bridgeEvent('UNIT VOICE,START,RX,{},{},{},{},{},{},{}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id), self._targets).encode(encoding='utf-8', errors='ignore'))
|
|
|
|
for _target in self._targets:
|
|
|
|
_target_status = systems[_target].STATUS
|
|
_target_system = self._CONFIG['SYSTEMS'][_target]
|
|
|
|
if self._CONFIG['SYSTEMS'][_target]['MODE'] == 'OPENBRIDGE':
|
|
if (_stream_id not in _target_status):
|
|
# This is a new call stream on the target
|
|
_target_status[_stream_id] = {
|
|
'START': pkt_time,
|
|
'CONTENTION':False,
|
|
'RFS': _rf_src,
|
|
'TYPE': 'UNIT',
|
|
'DST': _dst_id,
|
|
'ACTIVE': True
|
|
}
|
|
|
|
logger.info('(%s) Unit call bridged to OBP System: %s TS: %s, UNIT: %s', self._system, _target, _slot if _target_system['BOTH_SLOTS'] else 1, int_id(_dst_id))
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
systems[_target]._report.send_bridgeEvent('UNIT VOICE,START,TX,{},{},{},{},{},{}'.format(_target, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id)).encode(encoding='utf-8', errors='ignore'))
|
|
|
|
# Record the time of this packet so we can later identify a stale stream
|
|
_target_status[_stream_id]['LAST'] = pkt_time
|
|
# Clear the TS bit and follow propper OBP definition, unless "BOTH_SLOTS" is set. This only works for unit calls.
|
|
if _target_system['BOTH_SLOTS']:
|
|
_tmp_bits = _bits
|
|
else:
|
|
_tmp_bits = _bits & ~(1 << 7)
|
|
|
|
# Assemble transmit HBP packet
|
|
_tmp_data = b''.join([_data[:15], _tmp_bits.to_bytes(1, 'big'), _data[16:20]])
|
|
_data = b''.join([_tmp_data, dmrpkt])
|
|
|
|
if (_frame_type == HBPF_DATA_SYNC) and (_dtype_vseq == HBPF_SLT_VTERM):
|
|
_target_status[_stream_id]['ACTIVE'] = False
|
|
|
|
else:
|
|
# BEGIN STANDARD CONTENTION HANDLING
|
|
#
|
|
# The rules for each of the 4 "ifs" below are listed here for readability. The Frame To Send is:
|
|
# From a different group than last RX from this HBSystem, but it has been less than Group Hangtime
|
|
# From a different group than last TX to this HBSystem, but it has been less than Group Hangtime
|
|
# From the same group as the last RX from this HBSystem, but from a different subscriber, and it has been less than stream timeout
|
|
# From the same group as the last TX to this HBSystem, but from a different subscriber, and it has been less than stream timeout
|
|
# The "continue" at the end of each means the next iteration of the for loop that tests for matching rules
|
|
#
|
|
'''
|
|
if ((_dst_id != _target_status[_slot]['RX_TGID']) and ((pkt_time - _target_status[_slot]['RX_TIME']) < _target_system['GROUP_HANGTIME'])):
|
|
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD and self.STATUS[_slot]['RX_STREAM_ID'] != _stream_id:
|
|
logger.info('(%s) Call not routed to destination %s, target active or in group hangtime: HBSystem: %s, TS: %s, DEST: %s', self._system, int_id(_dst_id), _target, _slot, int_id(_target_status[_slot]['RX_TGID']))
|
|
continue
|
|
if ((_dst_id != _target_status[_slot]['TX_TGID']) and ((pkt_time - _target_status[_slot]['TX_TIME']) < _target_system['GROUP_HANGTIME'])):
|
|
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD and self.STATUS[_slot]['RX_STREAM_ID'] != _stream_id:
|
|
logger.info('(%s) Call not routed to destination %s, target in group hangtime: HBSystem: %s, TS: %s, DEST: %s', self._system, int_id(_dst_id), _target, _slot, int_id(_target_status[_slot]['TX_TGID']))
|
|
continue
|
|
'''
|
|
if (_dst_id == _target_status[_slot]['RX_TGID']) and ((pkt_time - _target_status[_slot]['RX_TIME']) < STREAM_TO):
|
|
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD and self.STATUS[_slot]['RX_STREAM_ID'] != _stream_id:
|
|
logger.info('(%s) Call not routed to destination %s, matching call already active on target: HBSystem: %s, TS: %s, DEST: %s', self._system, int_id(_dst_id), _target, _slot, int_id(_target_status[_slot]['RX_TGID']))
|
|
continue
|
|
if (_dst_id == _target_status[_slot]['TX_TGID']) and (_rf_src != _target_status[_slot]['TX_RFS']) and ((pkt_time - _target_status[_slot]['TX_TIME']) < STREAM_TO):
|
|
if _frame_type == HBPF_DATA_SYNC and _dtype_vseq == HBPF_SLT_VHEAD and self.STATUS[_slot]['RX_STREAM_ID'] != _stream_id:
|
|
logger.info('(%s) Call not routed for subscriber %s, call route in progress on target: HBSystem: %s, TS: %s, DEST: %s, SUB: %s', self._system, int_id(_rf_src), _target, _slot, int_id(_target_status[_slot]['TX_TGID']), int_id(_target_status[_slot]['TX_RFS']))
|
|
continue
|
|
|
|
# Record target information if this is a new call stream?
|
|
if (_stream_id != self.STATUS[_slot]['RX_STREAM_ID']):
|
|
# Record the DST TGID and Stream ID
|
|
_target_status[_slot]['TX_START'] = pkt_time
|
|
_target_status[_slot]['TX_TGID'] = _dst_id
|
|
_target_status[_slot]['TX_STREAM_ID'] = _stream_id
|
|
_target_status[_slot]['TX_RFS'] = _rf_src
|
|
_target_status[_slot]['TX_PEER'] = _peer_id
|
|
|
|
logger.info('(%s) Unit call bridged to HBP System: %s TS: %s, UNIT: %s', self._system, _target, _slot, int_id(_dst_id))
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
systems[_target]._report.send_bridgeEvent('UNIT VOICE,START,TX,{},{},{},{},{},{}'.format(_target, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id)).encode(encoding='utf-8', errors='ignore'))
|
|
|
|
# Set other values for the contention handler to test next time there is a frame to forward
|
|
_target_status[_slot]['TX_TIME'] = pkt_time
|
|
_target_status[_slot]['TX_TYPE'] = _dtype_vseq
|
|
|
|
#send the call:
|
|
systems[_target].send_system(_data)
|
|
|
|
|
|
# Final actions - Is this a voice terminator?
|
|
if (_frame_type == HBPF_DATA_SYNC) and (_dtype_vseq == HBPF_SLT_VTERM) and (self.STATUS[_slot]['RX_TYPE'] != HBPF_SLT_VTERM):
|
|
self._targets = []
|
|
call_duration = pkt_time - self.STATUS[_slot]['RX_START']
|
|
logger.info('(%s) *UNIT CALL END* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) UNIT %s (%s), TS %s, Duration: %.2f', \
|
|
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot, call_duration)
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
self._report.send_bridgeEvent('UNIT VOICE,END,RX,{},{},{},{},{},{},{:.2f}'.format(self._system, int_id(_stream_id), int_id(_peer_id), int_id(_rf_src), _slot, int_id(_dst_id), call_duration).encode(encoding='utf-8', errors='ignore'))
|
|
|
|
# Mark status variables for use later
|
|
self.STATUS[_slot]['RX_PEER'] = _peer_id
|
|
self.STATUS[_slot]['RX_SEQ'] = _seq
|
|
self.STATUS[_slot]['RX_RFS'] = _rf_src
|
|
self.STATUS[_slot]['RX_TYPE'] = _dtype_vseq
|
|
self.STATUS[_slot]['RX_TGID'] = _dst_id
|
|
self.STATUS[_slot]['RX_TIME'] = pkt_time
|
|
self.STATUS[_slot]['RX_STREAM_ID'] = _stream_id
|
|
|
|
|
|
def dmrd_received(self, _peer_id, _rf_src, _dst_id, _seq, _slot, _call_type, _frame_type, _dtype_vseq, _stream_id, _data):
|
|
if _call_type == 'group':
|
|
self.group_received(_peer_id, _rf_src, _dst_id, _seq, _slot, _frame_type, _dtype_vseq, _stream_id, _data)
|
|
elif _call_type == 'unit':
|
|
if self._system not in UNIT:
|
|
logger.error('(%s) *UNIT CALL NOT FORWARDED* UNIT calling is disabled for this system (INGRESS)', self._system)
|
|
else:
|
|
self.unit_received(_peer_id, _rf_src, _dst_id, _seq, _slot, _frame_type, _dtype_vseq, _stream_id, _data)
|
|
elif _call_type == 'vcsbk':
|
|
logger.debug('CSBK recieved, but HBlink does not process them currently. By default, CSBK packet will be forwarded to the talkgroup.')
|
|
self.group_received(_peer_id, _rf_src, _dst_id, _seq, _slot, _frame_type, _dtype_vseq, _stream_id, _data)
|
|
else:
|
|
logger.error('Unknown call type recieved -- not processed')
|
|
|
|
#
|
|
# Socket-based reporting section
|
|
#
|
|
class bridgeReportFactory(reportFactory):
|
|
|
|
def send_bridge(self):
|
|
serialized = pickle.dumps(BRIDGES, protocol=2) #.decode("utf-8", errors='ignore')
|
|
self.send_clients(REPORT_OPCODES['BRIDGE_SND']+serialized)
|
|
|
|
def send_bridgeEvent(self, _data):
|
|
if isinstance(_data, str):
|
|
_data = _data.decode('utf-8', error='ignore')
|
|
self.send_clients(REPORT_OPCODES['BRDG_EVENT']+_data)
|
|
|
|
|
|
#************************************************
|
|
# MAIN PROGRAM LOOP STARTS HERE
|
|
#************************************************
|
|
|
|
if __name__ == '__main__':
|
|
|
|
import argparse
|
|
import sys
|
|
import os
|
|
import signal
|
|
|
|
# Change the current directory to the location of the application
|
|
os.chdir(os.path.dirname(os.path.realpath(sys.argv[0])))
|
|
|
|
# CLI argument parser - handles picking up the config file from the command line, and sending a "help" message
|
|
parser = argparse.ArgumentParser()
|
|
parser.add_argument('-c', '--config', action='store', dest='CONFIG_FILE', help='/full/path/to/config.file (usually hblink.cfg)')
|
|
parser.add_argument('-r', '--rules', action='store', dest='RULES_FILE', help='/full/path/to/rules.file (usually rules.py)')
|
|
parser.add_argument('-l', '--logging', action='store', dest='LOG_LEVEL', help='Override config file logging level.')
|
|
cli_args = parser.parse_args()
|
|
|
|
# Ensure we have a path for the config file, if one wasn't specified, then use the default (top of file)
|
|
if not cli_args.CONFIG_FILE:
|
|
cli_args.CONFIG_FILE = os.path.dirname(os.path.abspath(__file__))+'/hblink.cfg'
|
|
|
|
# Call the external routine to build the configuration dictionary
|
|
CONFIG = config.build_config(cli_args.CONFIG_FILE)
|
|
|
|
# Ensure we have a path for the rules file, if one wasn't specified, then use the default (top of file)
|
|
if not cli_args.RULES_FILE:
|
|
cli_args.RULES_FILE = os.path.dirname(os.path.abspath(__file__))+'/rules.py'
|
|
|
|
# Start the system logger
|
|
if cli_args.LOG_LEVEL:
|
|
CONFIG['LOGGER']['LOG_LEVEL'] = cli_args.LOG_LEVEL
|
|
logger = log.config_logging(CONFIG['LOGGER'])
|
|
logger.info('\n\nCopyright (c) 2013, 2014, 2015, 2016, 2018, 2019, 2020\n\tThe Regents of the K0USY Group. All rights reserved.\n')
|
|
logger.debug('(GLOBAL) Logging system started, anything from here on gets logged')
|
|
|
|
# Set up the signal handler
|
|
def sig_handler(_signal, _frame):
|
|
logger.info('(GLOBAL) SHUTDOWN: CONFBRIDGE IS TERMINATING WITH SIGNAL %s', str(_signal))
|
|
hblink_handler(_signal, _frame)
|
|
logger.info('(GLOBAL) SHUTDOWN: ALL SYSTEM HANDLERS EXECUTED - STOPPING REACTOR')
|
|
reactor.stop()
|
|
|
|
# Set signal handers so that we can gracefully exit if need be
|
|
for sig in [signal.SIGINT, signal.SIGTERM]:
|
|
signal.signal(sig, sig_handler)
|
|
|
|
# Create the name-number mapping dictionaries
|
|
peer_ids, subscriber_ids, talkgroup_ids = mk_aliases(CONFIG)
|
|
|
|
# Import the ruiles file as a module, and create BRIDGES from it
|
|
spec = importlib.util.spec_from_file_location("module.name", cli_args.RULES_FILE)
|
|
rules_module = importlib.util.module_from_spec(spec)
|
|
try:
|
|
spec.loader.exec_module(rules_module)
|
|
logger.info('(ROUTER) Routing bridges file found and bridges imported: %s', cli_args.RULES_FILE)
|
|
except (ImportError, FileNotFoundError):
|
|
sys.exit('(ROUTER) TERMINATING: Routing bridges file not found or invalid: {}'.format(cli_args.RULES_FILE))
|
|
|
|
# Build the routing rules file
|
|
BRIDGES = make_bridges(rules_module.BRIDGES)
|
|
|
|
# Get rule parameter for private calls
|
|
UNIT = rules_module.UNIT
|
|
|
|
# INITIALIZE THE REPORTING LOOP
|
|
if CONFIG['REPORTS']['REPORT']:
|
|
report_server = config_reports(CONFIG, bridgeReportFactory)
|
|
else:
|
|
report_server = None
|
|
logger.info('(REPORT) TCP Socket reporting not configured')
|
|
|
|
# HBlink instance creation
|
|
logger.info('(GLOBAL) HBlink \'bridge.py\' -- SYSTEM STARTING...')
|
|
for system in CONFIG['SYSTEMS']:
|
|
if CONFIG['SYSTEMS'][system]['ENABLED']:
|
|
if CONFIG['SYSTEMS'][system]['MODE'] == 'OPENBRIDGE':
|
|
systems[system] = routerOBP(system, CONFIG, report_server)
|
|
else:
|
|
systems[system] = routerHBP(system, CONFIG, report_server)
|
|
reactor.listenUDP(CONFIG['SYSTEMS'][system]['PORT'], systems[system], interface=CONFIG['SYSTEMS'][system]['IP'])
|
|
logger.debug('(GLOBAL) %s instance created: %s, %s', CONFIG['SYSTEMS'][system]['MODE'], system, systems[system])
|
|
|
|
def loopingErrHandle(failure):
|
|
logger.error('(GLOBAL) STOPPING REACTOR TO AVOID MEMORY LEAK: Unhandled error in timed loop.\n %s', failure)
|
|
reactor.stop()
|
|
|
|
# Initialize the rule timer -- this if for user activated stuff
|
|
rule_timer_task = task.LoopingCall(rule_timer_loop)
|
|
rule_timer = rule_timer_task.start(60)
|
|
rule_timer.addErrback(loopingErrHandle)
|
|
|
|
# Initialize the stream trimmer
|
|
stream_trimmer_task = task.LoopingCall(stream_trimmer_loop)
|
|
stream_trimmer = stream_trimmer_task.start(5)
|
|
stream_trimmer.addErrback(loopingErrHandle)
|
|
|
|
reactor.run()
|