Scope GUI: amplitude and offset reset buttons. Fixes and updated documentation
This commit is contained in:
parent
f886f7d400
commit
2eb8abeb00
BIN
doc/img/ChAnalyzerNG_plugin_ampOffset.png
Normal file
BIN
doc/img/ChAnalyzerNG_plugin_ampOffset.png
Normal file
Binary file not shown.
After Width: | Height: | Size: 5.2 KiB |
BIN
doc/img/ChAnalyzerNG_plugin_ampOffset.xcf
Normal file
BIN
doc/img/ChAnalyzerNG_plugin_ampOffset.xcf
Normal file
Binary file not shown.
BIN
doc/img/ChAnalyzerNG_plugin_ampScale.png
Normal file
BIN
doc/img/ChAnalyzerNG_plugin_ampScale.png
Normal file
Binary file not shown.
After Width: | Height: | Size: 5.9 KiB |
BIN
doc/img/ChAnalyzerNG_plugin_ampScale.xcf
Normal file
BIN
doc/img/ChAnalyzerNG_plugin_ampScale.xcf
Normal file
Binary file not shown.
@ -312,31 +312,74 @@ This is for future use when more than one incoming complex signals can be applie
|
||||
|
||||
<h3>6. Amplitude adjustment</h3>
|
||||
|
||||
This slider lets you adjust the amplitude scale. The full scale value appears on the left of the slider. The unit depends on the projection.
|
||||
The amplitude range (vertical scale) can be set to any value from 1e-10 to 9.999e+10. Values are entered as mantissa (6.3 and 6.4) and exponent (6.5) values.
|
||||
|
||||
I/Q signal range is +/-1 however values larger than 1 are accomodated for the general usage of the scope in other plugins.
|
||||
|
||||
When displayed signal can be negative (+/- scale) the range is -range to +range. When displayed signal is positive (ex: magnitudes) the range is 0 to 2×range.
|
||||
|
||||
![Channel Analyzer NG plugin amplitude scale control](../../../doc/img/ChAnalyzerNG_plugin_ampScale.png)
|
||||
|
||||
<h4>6.1. Amplitude scale reset</h4>
|
||||
|
||||
Push this button to reset amplitude scale to 1.
|
||||
|
||||
<h4>6.2. Mantissa display</h4>
|
||||
|
||||
The amplitude range is M×10<sup>E</sup>. This displays the M value.
|
||||
|
||||
<h4>6.3 Mantissa fine control</h4>
|
||||
|
||||
This slider sets the decimal digits of the mantissa from .000 to .999
|
||||
|
||||
<h4>6.4 Mantissa coarse control</h4>
|
||||
|
||||
This dial button sets the integer part of the mantissa from 1 to 9.
|
||||
|
||||
<h4>6.5 Exponent control</h4>
|
||||
|
||||
This slider sets the exponent from -10 to +10. The value is displayed at the left of the slider in exponent notation.
|
||||
|
||||
<h4>6.6 Unit multiplier on vertical scale</h4>
|
||||
|
||||
This displays the unit multiplier for values on the vertical scale of the display.
|
||||
|
||||
- **p**: pico (×10<sup>-12</sup>)
|
||||
- **n**: nano (×10<sup>-9</sup>)
|
||||
- **μ**: micro (×10<sup>-6</sup>)
|
||||
- **m**: milli (×10<sup>-3</sup>)
|
||||
- **-**: none (×1)
|
||||
- **k**: kilo (×10<sup>3</sup>)
|
||||
- **M**: mega (×10<sup>6</sup>)
|
||||
- **G**: giga (×10<sup>9</sup>)
|
||||
|
||||
<h3>7. Offset adjustment</h3>
|
||||
|
||||
This pair of sliders let you offset the trace vertically. The offset value from reference appears on the left of the slider. The reference is either:
|
||||
The amplitude range can be offset by any value from -5×10<sup>-10</sup> to 5×10<sup>10</sup>.
|
||||
|
||||
- central zero value for Real, Imag, Phi and dPhi projections
|
||||
- bottom zero value for MagLin projection
|
||||
- bottom -200 dB value for MagDB projection
|
||||
I/Q signal range is +/-1 however values larger than 1 are accomodated for the general usage of the scope in other plugins.
|
||||
|
||||
The top slider is a coarse adjustment. Each step moves the trace by an amount that depends on the projection type:
|
||||
![Channel Analyzer NG plugin amplitude offset control](../../../doc/img/ChAnalyzerNG_plugin_ampOffset.png)
|
||||
|
||||
- Real, Imag: 0.01
|
||||
- Mag: 0.005
|
||||
- MagSq: 0.005
|
||||
- MagDB: 1 dB
|
||||
- Phi, dPhi: 0.01
|
||||
<h4>7.1. Amplitude offset reset</h4>
|
||||
|
||||
The bottom slider is a fine adjustment. Each step moves the trace by an amount that depends on the projection type:
|
||||
Push this button to reset amplitude offset to 0.
|
||||
|
||||
- Real, Imag: 50.0E-6
|
||||
- Mag: 25.0sE-6
|
||||
- MagSq: 25.0sE-6
|
||||
- MagDB: 0.01 dB
|
||||
- Phi, dPhi: 50.0E-6
|
||||
<h4>7.2. Mantissa display</h4>
|
||||
|
||||
The amplitude offset is M×10<sup>E</sup>. This displays the M value.
|
||||
|
||||
<h4>7.3 Mantissa fine control</h4>
|
||||
|
||||
This slider sets the decimal digits of the mantissa from .000 to 0.999 and jump to next unit (so 5.000 can be reached)
|
||||
|
||||
<h4>7.4 Mantissa coarse control</h4>
|
||||
|
||||
This dial button sets the integer part of the mantissa from -5 to 4.
|
||||
|
||||
<h4>7.5 Exponent control</h4>
|
||||
|
||||
This slider sets the exponent from -10 to +10. The value is displayed at the left of the slider in exponent notation.
|
||||
|
||||
<h3>8. Trace delay adjustment</h3>
|
||||
|
||||
|
@ -854,6 +854,16 @@ void GLScopeGUI::on_traceMode_currentIndexChanged(int index)
|
||||
changeCurrentTrace();
|
||||
}
|
||||
|
||||
void GLScopeGUI::on_ampReset_clicked(bool checked)
|
||||
{
|
||||
(void) checked;
|
||||
ui->amp->setValue(0);
|
||||
ui->ampCoarse->setValue(1);
|
||||
ui->ampExp->setValue(0);
|
||||
setAmpScaleDisplay();
|
||||
changeCurrentTrace();
|
||||
}
|
||||
|
||||
void GLScopeGUI::on_amp_valueChanged(int value)
|
||||
{
|
||||
(void) value;
|
||||
@ -875,6 +885,16 @@ void GLScopeGUI::on_ampExp_valueChanged(int value)
|
||||
changeCurrentTrace();
|
||||
}
|
||||
|
||||
void GLScopeGUI::on_ofsReset_clicked(bool checked)
|
||||
{
|
||||
(void) checked;
|
||||
ui->ofsFine->setValue(0);
|
||||
ui->ofsCoarse->setValue(0);
|
||||
ui->ofsExp->setValue(0);
|
||||
setAmpOfsDisplay();
|
||||
changeCurrentTrace();
|
||||
}
|
||||
|
||||
void GLScopeGUI::on_ofsCoarse_valueChanged(int value)
|
||||
{
|
||||
(void) value;
|
||||
@ -1526,12 +1546,12 @@ void GLScopeGUI::setTraceUI(const GLScopeSettings::TraceData& traceData)
|
||||
ui->ampExp->setValue(ampExp);
|
||||
setAmpScaleDisplay();
|
||||
|
||||
double ofsValue = traceData.m_amp;
|
||||
double ofsValue = traceData.m_ofs;
|
||||
int ofsExp;
|
||||
double ofsMant = CalcDb::frexp10(ofsValue, &ofsExp) * 10.0;
|
||||
int ofsCoarse = (int) ofsMant;
|
||||
int ofsFine = round((ofsMant - ofsCoarse) * 1000.0);
|
||||
ofsExp -= 1;
|
||||
ofsExp -= ofsMant == 0 ? 0 : 1;
|
||||
ui->ofsFine->setValue(ofsFine);
|
||||
ui->ofsCoarse->setValue(ofsCoarse);
|
||||
ui->ofsExp->setValue(ofsExp);
|
||||
|
@ -219,9 +219,11 @@ private slots:
|
||||
void on_traceDown_clicked(bool checked);
|
||||
void on_traceStream_currentIndexChanged(int index);
|
||||
void on_traceMode_currentIndexChanged(int index);
|
||||
void on_ampReset_clicked(bool checked);
|
||||
void on_amp_valueChanged(int value);
|
||||
void on_ampCoarse_valueChanged(int value);
|
||||
void on_ampExp_valueChanged(int value);
|
||||
void on_ofsReset_clicked(bool checked);
|
||||
void on_ofsCoarse_valueChanged(int value);
|
||||
void on_ofsFine_valueChanged(int value);
|
||||
void on_ofsExp_valueChanged(int value);
|
||||
|
@ -825,12 +825,18 @@ kS/s</string>
|
||||
</widget>
|
||||
</item>
|
||||
<item>
|
||||
<widget class="QLabel" name="ampLabel">
|
||||
<widget class="QPushButton" name="ampReset">
|
||||
<property name="maximumSize">
|
||||
<size>
|
||||
<width>22</width>
|
||||
<height>22</height>
|
||||
</size>
|
||||
</property>
|
||||
<property name="toolTip">
|
||||
<string>Vertical range</string>
|
||||
<string>Vertical range reset</string>
|
||||
</property>
|
||||
<property name="text">
|
||||
<string>A:</string>
|
||||
<string>A</string>
|
||||
</property>
|
||||
</widget>
|
||||
</item>
|
||||
@ -952,7 +958,7 @@ kS/s</string>
|
||||
</size>
|
||||
</property>
|
||||
<property name="toolTip">
|
||||
<string>Vertical range value</string>
|
||||
<string>Unit multiplier on vertical scale</string>
|
||||
</property>
|
||||
<property name="text">
|
||||
<string>-</string>
|
||||
@ -974,12 +980,18 @@ kS/s</string>
|
||||
</widget>
|
||||
</item>
|
||||
<item>
|
||||
<widget class="QLabel" name="ofsLabel">
|
||||
<widget class="QPushButton" name="ofsReset">
|
||||
<property name="maximumSize">
|
||||
<size>
|
||||
<width>22</width>
|
||||
<height>22</height>
|
||||
</size>
|
||||
</property>
|
||||
<property name="toolTip">
|
||||
<string>Vertical offset</string>
|
||||
<string>Vertical offset reset</string>
|
||||
</property>
|
||||
<property name="text">
|
||||
<string>O:</string>
|
||||
<string>O</string>
|
||||
</property>
|
||||
</widget>
|
||||
</item>
|
||||
|
Loading…
Reference in New Issue
Block a user