mirror of
				https://github.com/f4exb/sdrangel.git
				synced 2025-10-30 20:40:20 -04:00 
			
		
		
		
	Update docs
This commit is contained in:
		
							parent
							
								
									3a8a0f0bf0
								
							
						
					
					
						commit
						4462078ead
					
				| @ -34,12 +34,12 @@ that corresponds to the set frequency is being recieved. | ||||
| 
 | ||||
| <h3>6: t_s - Scan time</h3> | ||||
| 
 | ||||
| Specifies the time in seconds that the Frequency Scanner will average its channel power measurement over. | ||||
| Specifies the time in seconds that the Frequency Scanner will average its power measurement over. | ||||
| 
 | ||||
| <h3>7: t_rtx - Retransmission Time</h3> | ||||
| 
 | ||||
| Specifies the time in seconds that the Frequency Scanner will wait after the power on the active frequency falls below the threshold, before restarting | ||||
| scanning. This allows for a temporary break in transmission. | ||||
| scanning. This enables the channel to remain tuned to a single frequency while there is a temporary break in transmission. | ||||
| 
 | ||||
| <h3>8: Ch BW - Channel Bandwidth</h3> | ||||
| 
 | ||||
| @ -86,9 +86,9 @@ Displays the current status of the Frequency Scanner. | ||||
| The frequency table contains the list of frequencies to be scanned, along with results of a scan. The columns are: | ||||
| 
 | ||||
| - Freq (Hz): Specifies the channel center frequencies to be scanned. These should be spaced by integer multiples of the channel bandwidth (8). Values should be entered in Hertz. | ||||
| - Annotation: An annotation (description) for the frequency, that is based on the closest matching [annotation marker](../../../sdrgui/gui/spectrummarkers.md) in the Main Spectrum. | ||||
| - Annotation: An annotation (description) for the frequency, that is obtained from the closest matching [annotation marker](../../../sdrgui/gui/spectrummarkers.md) in the Main Spectrum. | ||||
| - Enable: Determines whether the frequency will be scanned. This can be used to temporaily disable frequencies you aren't interested in. | ||||
| - Power (dB): Displays the measured power in decibels during the previous scan. The cell will have a green background if the power was above the threshold (4). | ||||
| - Power (dB): Displays the measured power in decibels from the last scan. The cell will have a green background if the power was above the threshold (4). | ||||
| - Active Count: Displays the number of scans in which the power for this frequency was above the threshold (4). This allows you to see which frequencies are commonly in use. | ||||
| - Notes: Available for user-entry of notes/information about this frequency. | ||||
| 
 | ||||
|  | ||||