sdrangel/plugins/channeltx/localsource
f4exb 9610a6b93a REST API: config (7): preset channel Tx adapters where there is no CW keyer 2019-08-03 01:05:16 +02:00
..
CMakeLists.txt REST API: config (7): preset channel Tx adapters where there is no CW keyer 2019-08-03 01:05:16 +02:00
localsource.cpp REST API: config: GET (5): all API supported channels refactoring to use static methods for settings GET. PUT. PATCH 2019-08-03 01:05:16 +02:00
localsource.h REST API: config: GET (5): all API supported channels refactoring to use static methods for settings GET. PUT. PATCH 2019-08-03 01:05:16 +02:00
localsource.pro Local Output/Sink: updated documentation 2019-05-11 00:42:21 +02:00
localsourcegui.cpp MIMO: channel marker affinity with the stream being displayed on the main spectrum. Implemented in demod AM 2019-05-30 18:38:10 +02:00
localsourcegui.h Added the Local Source plugin 2019-05-10 13:20:30 +02:00
localsourcegui.ui Added the Local Source plugin 2019-05-10 13:20:30 +02:00
localsourceplugin.cpp REST API: config (7): preset channel Tx adapters where there is no CW keyer 2019-08-03 01:05:16 +02:00
localsourceplugin.h REST API: config (7): preset channel Tx adapters where there is no CW keyer 2019-08-03 01:05:16 +02:00
localsourcesettings.cpp Local Output/Sink: updated documentation 2019-05-11 00:42:21 +02:00
localsourcesettings.h Added the Local Source plugin 2019-05-10 13:20:30 +02:00
localsourcethread.cpp Added the Local Source plugin 2019-05-10 13:20:30 +02:00
localsourcethread.h Added the Local Source plugin 2019-05-10 13:20:30 +02:00
localsourcewebapiadapter.cpp REST API: config (7): preset channel Tx adapters where there is no CW keyer 2019-08-03 01:05:16 +02:00
localsourcewebapiadapter.h REST API: config (7): preset channel Tx adapters where there is no CW keyer 2019-08-03 01:05:16 +02:00
readme.md Local Output/Sink: updated documentation 2019-05-11 00:42:21 +02:00

readme.md

Local source channel plugin

Introduction

This plugin draws I/Q samples from a Local Output plugin device sink in another device set into the baseband. It is basically the same as the Remote Source channel plugin but pipes the samples internally instead of receiving them over the network.

It may be used when you want to use a particular sub area of the baseband for madulation.

Note that because it uses only the channelizer half band filter chain to achieve interpolation and center frequency shift you have a limited choice on the center frequencies that may be used (similarly to the Remote Source). The available center frequencies depend on the baseband sample rate, the channel interpolation and the filter chain that is used so you have to play with these parameters to obtain a suitable center frequency and pass band.

Interface

Local source channel plugin GUI

1: Interpolation factor

The device baseband can be interpolated from the channel and its center can be selected with (5). The resulting sample rate of the I/Q stream pulled from the Local Output device sink is the baseband sample rate divided by this value. The value is displayed in (2).

2: I/Q stream sample rate

This is the sample rate in kS/s of the I/Q stream pulled from the Local Output device sink instance.

3: Half-band filters chain sequence

This string represents the sequence of half-band filters used in the interpolation. Each character represents a filter type:

  • L: lower half-band
  • H: higher half-band
  • C: centered

4: Center frequency shift

This is the shift of the channel center frequency from the device center frequency. Its value is driven by the device sample rate, the interpolation (1) and the filter chain sequence (5).

5: Half-band filter chain sequence

The slider moves the channel center frequency roughly from the lower to the higher frequency in the device baseband. The number on the right represents the filter sequence as the decimal value of a base 3 number. Each base 3 digit represents the filter type and its sequence from MSB to LSB in the filter chain:

  • 0: lower half-band
  • 1: centered
  • 2: higher half-band

6: Local Output source index

This selects the index of the Local Output device sink from which to pull the I/Q samples. The list can be refreshed with the next button (7)

7: Refresh local output devices list

Use this button to refresh the list of Local Output device sinks indexes.