.. | ||
chanalyzer.cpp | ||
chanalyzer.h | ||
chanalyzer.pro | ||
chanalyzergui.cpp | ||
chanalyzergui.h | ||
chanalyzergui.ui | ||
chanalyzerplugin.cpp | ||
chanalyzerplugin.h | ||
chanalyzersettings.cpp | ||
chanalyzersettings.h | ||
CMakeLists.txt | ||
readme.md |
Channel Analyzer (New Generation) plugin
A. Introduction
This is an enhancement of the Channel Analyzer plugin with a new scope display hence the "New Generation" or "NG" qualifier.
This plugin can be used to analyze the complex signal received in its passband. You can visualize the spectrum (Channel Spectrum section) or waveforms related to the complex signal (Channel Scope section). These waveforms can be:
- Real part
- Imaginary part
- Magnitude linear
- Power i.e. squared magnitude linear
- Power i.e. squared magnitude log (dB)
- Phase
- Phase derivative (instant frequency)
- BPSK symbol mapping
- QPSK symbol mapping
- 8-PSK symbol mapping
- 16-PSK symbol mapping
The same waveforms can be used to trigger the scope trace
B. General interface
The interface is essentially divided in the following sections
- Channel controls
- Scope view (Channel scope)
- Scope global controls
- Scope trace control
- Scope trigger control
Note: the spectrum view (Channel spectrum) is not presented here.
C. Channel controls
1: Frequency shift from center frequency of reception
Use the wheels to adjust the frequency shift in Hz from the center frequency of reception. Left click on a digit sets the cursor position at this digit. Right click on a digit sets all digits on the right to zero. This effectively floors value at the digit position. Wheels are moved with the mousewheel while pointing at the wheel or by selecting the wheel with the left mouse click and using the keyboard arrows. Pressing shift simultaneously moves digit by 5 and pressing control moves it by 2.
2: Locked loop
Locks a PLL or FLL (depends on control 3) on the signal and mixes its NCO with the input signal. This is mostly useful for carrier recovery on PSK modulations (PLL is used). This effectively de-rotates the signal and symbol points (constellation) can be seen in XY mode with real part as X and imagiary part as Y.
When the PLL is locked the icon lights up in green. The frequency shift from carrier appears in the tooltip. Locking indicator is pretty sharp with about +/- 100 Hz range. The FLL has no indicator.
3: Locked loop mode
Use this combo to control the locked loop type:
- 1: PLL with no phase modulation. Locks to CW carrier.
- 2: PLL for BPSK modulation (bi-phase). Locks to a BPSK transmission
- 4: PLL for QPSK modulation (quad-phase). Locks to a QPSK transmission
- 8: PLL for 8-PSK modulation (octo-phase). Locks to a 8-PSK transmission
- 16: PLL for 16-PSK modulation (16-phase). Locks to a 16-PSK transmission
- F: FLL. Actually a frequency follower. This effectively implements an AFC for FM modulations.
4: Toggle the rational downsampler
The input channel sample rate is given by the source device sample rate possibly downsampled by a power of two in the source device plugin. This input sample rate can be optionally downsampled to any value using a rational downsampler. This allows a precise control of the timings independently of the source plugin sample rate. Some devices are flexible on their sample rate some like the Airspy are not.
5: Rational downsampler output rate
Use the wheels to adjust the sample rate that will be used in the rest of the signal processing in the channel. Left click on a digit sets the cursor position at this digit. Right click on a digit sets all digits on the right to zero. This effectively floors value at the digit position. The minimum value is 2000 S/s and the maximum value is the source plugin output sample rate. Wheels are moved with the mousewheel while pointing at the wheel or by selecting the wheel with the left mouse click and using the keyboard arrows. Pressing shift simultaneously moves digit by 5 and pressing control moves it by 2.
6: Downsampler by a power of two
This combo can select a further downsampling by a power of two. This downsampling applies on the signal coming either directly from the source plugin when the rational downsampler is disabled or from the output of the rational downsampler if it is engaged.
7: Processing sample rate
This is the resulting sample rate that will be used by the spectrum and scope visualizations
8: signal selection
Use this combo to select which (complex) signal to use as the display source:
- Sig: the main signal possibly mixed with PLL/FLL output (see 2 and 3)
- Lock: the output signal (NCO) from PLL or FLL
- ACorr: Auto-correlation of the main signal. It is a fixed 4096 point auto-correlation using FFT technique thus spanning the length of 4096 samples. The trace may show more samples in which case you will see the successive auto-correlation results.
☞ Auto-correlation hint: because there is always a peak of magnitude at t=0 triggering on the magnitude will make sure the trace starts at t=0
9. Channel power
Average total power in dB relative to a +/- 1.0 amplitude signal received in the pass band.
10. Toggle root raised cosine filter
Use this toggle button to activate or de-activate the root raised cosine (RRC) filter. When active the bnadpass boxcar filter is replaced by a RRC filter. This takes effect only in normal (DSB) mode (see control 14).
11. Tune RRC filter rolloff factor
This button tunes the rolloff factor (a.k.a alpha) of the RRC filter in 0.01 steps between 0.1 and 0.7. Default is 0.35.
12. Select lowpass filter cut-off frequency
In SSB mode this filter is a complex filter that can lowpass on either side of the center frequency. It is therefore labeled as "LP". For negative frequencies (LSB) the cut-off frequency is therefore negative. In fact setting a negative frequency in SSB mode automatically turns on the LSB mode processing and the spectrum is reversed.
In normal (DSB) mode this filter is a real filter that lowpass on both sides of the zero (center) frequency symmetrically. Therefore it acts as a bandpass filter centered on the zero frequency and therefore it is labeled as "BP". The value displayed in (9) is the full bandwidth of the filter.
13. Lowpass filter cut-off frequency
In SSB mode this is the complex cut-off frequency and is negative for LSB.
In normal (DSB) mode this is the full bandwidth of the real lowpass filter centered around zero frequency.
14. SSB filtering
When this toggle is engaged the signal is filtered either above (USB) or below (LSB) the channel center frequency. The sideband is selected according to the sign of the lowpass filter cut-off frequency (8): if positive the USB is selected else the LSB. In LSB mode the spectrum is reversed.
When SSB is off the lowpass filter is actually a bandpass filter around the channel center frequency.
15. Select highpass filter cut-off frequency
In SSB mode this controls the cut-off frequency of the complex highpass filter which is the filter closest to the zero frequency. This cut-off frequency is always at least 0.1 kHz in absolute value below the lowpass filter cut-off frequency (8).
In normal (DSB) mode this filter is not active.
16. Highpass filter cut-off frequency
This is the cut-off frequency of the highpass filter in kHz. It is zero or negative in LSB mode.
D. Scope global controls line
1. X only display
Scope displays are categorized in the X display for trace index 0 and Y display for traces with indexes > 0. Thus the trace index 0 is named the "X" trace and traces with index > 0 are named "Yn" traces where n is the trace index thus Y1, Y2, Y3, Y4 as there is a maximum of 5 traces.
This button selects the "X" trace display only on the whole surface of the scope screen
2. Y only display
This button selects the display of all "Yn" traces on the whole surface of the scope screen
3. X and Y displays horizontally arranged
This button selects the display of "X" and "Yn" traces side by side with "X" trace on the left
4. X and Y displays vertically arranged
This button selects the display of "X" and "Yn" traces on top of each other with "X" trace on the top
5. All traces and polar display
This button selects the display of all traces on the left side of the screen and the polar display of the "Yn" traces using the "X" trace as the x coordinates.
6. Line or points only display on the 2D XY display (right)
Use this button to toggle points display (on) or line display (off) for the 2D XY display on the right. The points display may yield a more visible graph when the distinct artifact is an accumulation of points.
7. Select trace intensity
This button lets you adjust the traces intensity. The value in percent of the maximum intensity appears as a tooltip
8. Select grid intensity
This button lets you adjust the grid intensity. The value in percent of the maximum intensity appears as a tooltip
9. Displayed trace length
This slider lets you adjust the length of the traces on display. Each step further divides the length of the full trace controlled by (10). The duration of the full length shown on display appears on the left of the slider and the corresponding number of samples appears as a tooltip.
10. Trace offset
This slider lets you move the start of traces on display. Each step moves the trace by an amount of time corresponding to 1/100 of the length of the full trace controlled by (10). The time offset from the start of the traces appears on the left of the slider and the corresponding number of samples appears as a tooltip.
11. Trace length
This slider lets you control the full length of the trace. Each step increases the corresponding amount of samples by 4800 samples with a minimum of 4800 samples and a maximum of 20*4800 = 96000 samples. The duration of a full trace appears on the left of the slider and he corresponding number of samples appears as a tooltip.
12. Trace sample rate
This is the sample rate used by the scope and corresponds to the final sample rate after the whole decimation chain. It should be the same amount as the one displayed on the plugin control (C.6)
E. Scope trace control line
Traces are arranged as the X trace for trace index 0 and Y traces for traces with indexes > 0. The Y traces are suffixed by a trace number corresponding to the trace index thus we have Y1, Y2, Y3 and Y4 traces as there is a maximum of 5 traces. In the polar display the X trace is used for the x coordinates and the Y traces for y coordinates hence their name.
1.Select trace
This button lets you select which trace is affected by the controls. The trace name appears on the left of the button. The Y scale and the top right overlay on the displays also correspond to the selected trace (4).
2. Add/delete trace
The top "+" button lets you add a new trace. The trace controls are copied from the current selected trace. The bottom "-" button deletes the currently selected trace. You can never delete the first trace (X trace). Use the move buttons (see next) when you want to change the X trace.
3. Move trace
The top button with the up arrow lets you move the currently selected trace up by one index position. Thus the trace at the next position takes the current position and the trace at the current position takes the next position. This movement can wrap around so when the last trace is selected and moved up it will take the place of the first trace which is the X trace.
The bottom button with the down arrow lets you move the currently selected trace down by one index position. Thus the trace at the position below takes the current position and the trace at the current position takes the position below. This movement does not wrap around so the first trace (the X trace) cannot be moved down.
4. Projection selector
To construct a trace which represents real values the incoming complex signal must be "projected" on the real axis. This combo lets you select the projection scheme:
- Real: take the real part
- Imag: take the imaginary part
- Mag: calculate magnitude in linear representation. This is just the module of the complex sample
- MagSq: calculate power in linear representation. This is the squared module of the complex sample
- MagDB: calculate power in log representation as 10*log10(x) or decibel (dB) representation. This is the squared module of the complex sample expressed in decibels
- Phi: instantaneous phase. This is the argument of the complex sample.
- dPhi: instantaneous derivative of the phase. This is the difference of arguments between successive samples thus represents the instantaneous frequency.
- BPSK: maps -π to π phase into two π wide sectors centered on 0 and π on the -1 to +1 range (sector is 1.0 wide):
- 0 → 0.5,
- π → -0.5
- QPSK: maps -π to π phase into four π/2 wide sectors centered on 0, π/2, π, -π/2 on the -1 to +1 range (sector is 0.5 wide):
- 0 → 0.25
- π/2 → 0.75
- π → -0.75
- -π/2 → -0.25
- 8PSK: maps -π to π phase into eight π/4 wide sectors centered on 0, π/4, π/2, 3π/4, π, -3π/4, -π/2, -π/4 on the -1 to +1 range (sector is 0.25 wide):
- 0 → 0.125
- π/4 → 0.375
- π/2 → 0.625
- 3π/4 → 0.875
- π → -0.875
- -3π/4 → -0.625
- -π/2 → -0.375
- -π/4 → -0.125
- 16PSK: maps -π to π phase into sixteen π/8 wide sectors centered on 0, π/8, π/4, 3π/8, π/2, 5π/8, 3π/4, 7π/8, π, -7π/8, -3π/4, -5π/8, -π/2, -3π/8, -π/4, -π/8 on the -1 to +1 range (sector is 0.125 wide):
- 0 → 0.0625
- π/8 → 0.1875
- π/4 → 0.3125
- 3π/8 → 0.4375
- π/2 → 0.5625
- 5π/8 → 0.6875
- 3π/4 → 0.8125
- 7π/8 → 0.9375
- π → -0.9375
- -7π/8 → -0.8125
- -3π/4 → -0.6875
- -5π/8 → -0.5625
- -π/2 → -0.4375
- -3π/8 → -0.3125
- -π/4 → -0.1875
- -π/8 → -0.0625
Note1: example of QPSK projection on a synchronized Tetra signal:
The signal is synchronized with the PLL in 4 phase mode (locker icon is green).
- A Tetra signal is QPSK modulated at 18 kSym/s therefore the sample rate is set at 90 kS/s thus we have an integer number of samples per symbol (5 samples per symbol). See green square.
- We have set two traces (X and Y1) with QPSK projection. The Y1 trace is delayed by two symbols (10 samples) which makes a 111.11 μs delay. See blue square
- In XY mode on the XY display (right) we can see an accumulation of points around the 16 possible symbol transitions. In two places the same symbol is repeated several times which results in a stronger accumulation. One is with the symbol at 0 (see red circle and square) and the other is with the symbol at π (see yellow circle and square).
- On the left panel of the XY mode display we can see that the 4 possible symbols mark 4 vertical stronger areas centered on 0.25, 0.75, -0.25 and -0.75.
Note2: in the MagDB mode when the trace is selected (1) the display overlay on the top right of the trace shows 3 figures. From left to right: peak power in dB, average power in dB and peak to average difference in dB.
Note3: in the MagSq mode when the trace is selected (1) the display overlay on the top right of the trace shows 2 figures in scientific notation. From left to right: peak power and average power.
5. Source select
This is for future use when more than one incoming complex signals can be applied. The signal index appears on the right of the button
6. Amplitude adjustment
This slider lets you adjust the amplitude scale. The full scale value appears on the left of the slider. The unit depends on the projection.
7. Offset adjustment
This pair of sliders let you offset the trace vertically. The offset value from reference appears on the left of the slider. The reference is either:
- central zero value for Real, Imag, Phi and dPhi projections
- bottom zero value for MagLin projection
- bottom -200 dB value for MagDB projection
The top slider is a coarse adjustment. Each step moves the trace by an amount that depends on the projection type:
- Real, Imag: 0.01
- Mag: 0.005
- MagSq: 0.005
- MagDB: 1 dB
- Phi, dPhi: 0.01
The bottom slider is a fine adjustment. Each step moves the trace by an amount that depends on the projection type:
- Real, Imag: 50.0E-6
- Mag: 25.0sE-6
- MagSq: 25.0sE-6
- MagDB: 0.01 dB
- Phi, dPhi: 50.0E-6
8. Trace delay adjustment
This pair of sliders let you control the time offset of the trace from the global starting point. The time offset value appears on the left of the slider and the corresponding number of samples appears as a tooltip.
The top slider is a coarse adjustment. Each step moves trace by 100 samples
The bottom slider is a fine adjustment. Each step moves trace by 1 sample
9. Trace display enable
By default the trace display is enabled and this checkbox is checked. You can optionally "mute" the trace by unchecking this checkbox.
10. Trace color
This area shows the current trace color. When clicking on it a color chooser dialog appears that lets you change the color of the current trace
11. Save traces in memory
While in memory mode (see E.13 next) use this button to save the bank of traces in memory (50 last traces) to file. A file dialog will open to let you choose the file name and locaion. By default the file extension is .trcm
.
12. Load traces into memory
While in memory mode (see E.13 next) use this button to load traces previously saved to file using the (E.11) button into the traces memory bank (50 traces). A file dialog will open to let you select the file. It will look for files with .trcm
extension by default.
13. Memory select
The last 50 traces are stored in memory and this button lets you browse through traces in memory. The memory index appears on the left of the button. Traces in memory are sorted from latest (1) to oldest (50). The memory index 0 is the current live trace. When indexes > 0 are selected the live trace is suspended.
It is the complex signal that is memorized actually so when a trace in memory is selected you can still use the global and trace controls to change the display. In particular the projection mode and the number of traces can be changed. Only the full trace length cannot be modified. When in memory mode the triggers are disabled since they only apply to a live trace.
While in memory trace the save (E.11) and load (E.12) traces to file buttons can be used.
F. Trigger control line
1. Select trigger
This button lets you select which trigger condition is affected by the controls. The trigger index appears on the left of the button.
Up to 10 triggers (index 0..9) can be chained to give the final trigger top. The first trigger condition (index 0) is tested then if the trigger is raised the next trigger condition (index 1) is activated then when trigger is raised it passes control to the next trigger etc... until the last trigger is raised then the trace process starts. This established to point in time of the trigger. Optionally the trace can start some time before this point (this is pre-trigger - see 11)
2. Add/delete trigger
The top "+" button lets you add a new trigger condition. The trigger condition details are copied from the current selected trigger. The bottom "-" button deletes the currently selected trigger. You can never delete the first trigger (index 0).
3. Move trigger
The top button with the up arrow lets you move the currently selected trigger up by one index position. Thus the trigger at the next position takes the current position and the trigger at the current position takes the next position. This movement can wrap around so when the last trigger is selected and moved up it will take the place of the first trigger at index 0.
The bottom button with the down arrow lets you move the currently selected trigger down by one index position. Thus the trigger at the position below takes the current position and the trigger at the current position takes the position below. This movement does not wrap around so the first trigger (at index 0) cannot be moved down.
4. Projection selector
The trigger tests a threshold from real values therefore the incoming complex signal must be "projected" on the real axis before testing. The projection schemes are the same used in for calculating the traces (E.4):
Real: take the real part Imag: take the imaginary part Mag: calculate magnitude in linear representation. This is just the module of the complex sample MagDB: calculate power in log representation as 10*log10(x) or decibel (dB) representation. This is the squared module of the complex sample expressed in decibels Phi: instantaneous phase. This is the argument of the complex sample. dPhi: instantaneous derivative of the phase. This is the difference of arguments between successive samples thus represents the instantaneous frequency.
5. Trigger repetition
This number of trigger conditions must be met before the actual trigger is raised.
6. Positive edge select
This button selects the positive edge triggering. Trigger is raised only of the current sample is above threshold and the previous sample is below threshold
7. Positive edge select
This button selects the negative edge triggering. Trigger is raised only of the current sample is below threshold and the previous sample is above threshold
8. Both edges select
This button selects both signal edges triggering. Trigger is raised if the signal crosses threshold in any direction. This actually combines the positive and negative edge testing with an or condition.
9. Trigger level adjustment
This pair of sliders let you adjust the trigger level, The level appears on the left of the sliders.
The top slider is a coarse adjustment. Each step moves the trigger level by an amount that depends on the projection type:
- Real, Imag: 0.01
- Mag: 0.01
- MagSq: 0.01
- MagDB: 1 dB
- Phi, dPhi: 0.01
The bottom slider is a fine adjustment. Each step moves the trigger level by an amount that depends on the projection type:
- Real, Imag: 20.0E-6
- Mag: 20.0sE-6
- MagSq: 20.0sE-6
- MagDB: 0.01 dB
- Phi, dPhi: 20.0E-6
10: Trigger delay
The actual trigger top can be moved forward by a number of samples. This pair of slider lets you adjust this delay. The delay in time units appears at the left of the sliders and the amount of samples as a tooltip
The top slider is a coarse adjustment. Each step moves the delay by a trace length. The bottom slider is a fine adjustment. Each step moves the delay by 20 samples
11. Pre-trigger delay
The trace can start an amount of time before the trigger top. This pair of sliders let you adjust this amount of time which is displayed at the left of the sliders. The corresponding number of samples appear as a tooltip.
The top slider is a coarse adjustment. Each step moves the delay by a hundreth of the trace length. The bottom slider is a fine adjustment. Each step moves the delay by 20 samples.
12. Trigger line color
This area shows the current trigger line color. When clicking on it a color chooser dialog appears that lets you change the color of the current trigger line color. This line appears when the selected trace projection matches the trigger projection.
13. One-shot trigger
This button toggles a one shot trigger. When the (final) trigger is raised only one trace is processed until the button is released.
14. Freerun
When active the triggers are disabled and traces are processed continuously. This is the default at plugin start time.