f1260fc759
* Only keep modem config copy Change-Id: I5fe0ee43ea5c27b8903a8236a1a528a7f5ab784d
53 lines
2.7 KiB
Bash
53 lines
2.7 KiB
Bash
#! /vendor/bin/sh
|
|
|
|
# Copyright (c) 2009-2016, The Linux Foundation. All rights reserved.
|
|
#
|
|
# Redistribution and use in source and binary forms, with or without
|
|
# modification, are permitted provided that the following conditions are met:
|
|
# * Redistributions of source code must retain the above copyright
|
|
# notice, this list of conditions and the following disclaimer.
|
|
# * Redistributions in binary form must reproduce the above copyright
|
|
# notice, this list of conditions and the following disclaimer in the
|
|
# documentation and/or other materials provided with the distribution.
|
|
# * Neither the name of The Linux Foundation nor
|
|
# the names of its contributors may be used to endorse or promote
|
|
# products derived from this software without specific prior written
|
|
# permission.
|
|
#
|
|
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
|
|
# AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
|
# IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
|
|
# NON-INFRINGEMENT ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
|
|
# CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
|
|
# EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO,
|
|
# PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS;
|
|
# OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY,
|
|
# WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
|
|
# OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
|
|
# ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
|
#
|
|
|
|
#
|
|
# Make modem config folder and copy firmware config to that folder for RIL
|
|
#
|
|
if [ -f /data/vendor/modem_config/ver_info.txt ]; then
|
|
prev_version_info=`cat /data/vendor/modem_config/ver_info.txt`
|
|
else
|
|
prev_version_info=""
|
|
fi
|
|
|
|
cur_version_info=`cat /vendor/firmware_mnt/verinfo/ver_info.txt`
|
|
if [ ! -f /vendor/firmware_mnt/verinfo/ver_info.txt -o "$prev_version_info" != "$cur_version_info" ]; then
|
|
# add W for group recursively before delete
|
|
chmod g+w -R /data/vendor/modem_config/*
|
|
rm -rf /data/vendor/modem_config/*
|
|
# preserve the read only mode for all subdir and files
|
|
cp --preserve=m -dr /vendor/firmware_mnt/image/modem_pr/mcfg/configs/* /data/vendor/modem_config
|
|
cp --preserve=m -d /vendor/firmware_mnt/verinfo/ver_info.txt /data/vendor/modem_config/
|
|
cp --preserve=m -d /vendor/firmware_mnt/image/modem_pr/mbn_ota.txt /data/vendor/modem_config/
|
|
# the group must be root, otherwise this script could not add "W" for group recursively
|
|
chown -hR radio.root /data/vendor/modem_config/*
|
|
fi
|
|
chmod g-w /data/vendor/modem_config
|
|
setprop ro.vendor.ril.mbn_copy_completed 1
|