android_kernel_xiaomi_sm8350/arch/um/kernel/trap_kern.c

220 lines
5.2 KiB
C
Raw Normal View History

/*
* Copyright (C) 2000, 2001 Jeff Dike (jdike@karaya.com)
* Licensed under the GPL
*/
#include "linux/kernel.h"
#include "asm/errno.h"
#include "linux/sched.h"
#include "linux/mm.h"
#include "linux/spinlock.h"
#include "linux/config.h"
#include "linux/init.h"
#include "linux/ptrace.h"
#include "asm/semaphore.h"
#include "asm/pgtable.h"
#include "asm/pgalloc.h"
#include "asm/tlbflush.h"
#include "asm/a.out.h"
#include "asm/current.h"
#include "asm/irq.h"
#include "sysdep/sigcontext.h"
#include "user_util.h"
#include "kern_util.h"
#include "kern.h"
#include "chan_kern.h"
#include "mconsole_kern.h"
#include "mem.h"
#include "mem_kern.h"
#ifdef CONFIG_MODE_SKAS
#include "skas.h"
#endif
/* Note this is constrained to return 0, -EFAULT, -EACCESS, -ENOMEM by segv(). */
int handle_page_fault(unsigned long address, unsigned long ip,
int is_write, int is_user, int *code_out)
{
struct mm_struct *mm = current->mm;
struct vm_area_struct *vma;
pgd_t *pgd;
pud_t *pud;
pmd_t *pmd;
pte_t *pte;
int err = -EFAULT;
*code_out = SEGV_MAPERR;
/* If the fault was during atomic operation, don't take the fault, just
* fail. */
if (in_atomic())
goto out_nosemaphore;
down_read(&mm->mmap_sem);
vma = find_vma(mm, address);
if(!vma)
goto out;
else if(vma->vm_start <= address)
goto good_area;
else if(!(vma->vm_flags & VM_GROWSDOWN))
goto out;
else if(is_user && !ARCH_IS_STACKGROW(address))
goto out;
else if(expand_stack(vma, address))
goto out;
good_area:
*code_out = SEGV_ACCERR;
if(is_write && !(vma->vm_flags & VM_WRITE))
goto out;
/* Don't require VM_READ|VM_EXEC for write faults! */
if(!is_write && !(vma->vm_flags & (VM_READ | VM_EXEC)))
goto out;
do {
survive:
switch (handle_mm_fault(mm, vma, address, is_write)){
case VM_FAULT_MINOR:
current->min_flt++;
break;
case VM_FAULT_MAJOR:
current->maj_flt++;
break;
case VM_FAULT_SIGBUS:
err = -EACCES;
goto out;
case VM_FAULT_OOM:
err = -ENOMEM;
goto out_of_memory;
default:
BUG();
}
pgd = pgd_offset(mm, address);
pud = pud_offset(pgd, address);
pmd = pmd_offset(pud, address);
pte = pte_offset_kernel(pmd, address);
} while(!pte_present(*pte));
err = 0;
WARN_ON(!pte_young(*pte) || (is_write && !pte_dirty(*pte)));
flush_tlb_page(vma, address);
out:
up_read(&mm->mmap_sem);
out_nosemaphore:
return(err);
/*
* We ran out of memory, or some other thing happened to us that made
* us unable to handle the page fault gracefully.
*/
out_of_memory:
if (current->pid == 1) {
up_read(&mm->mmap_sem);
yield();
down_read(&mm->mmap_sem);
goto survive;
}
goto out;
}
[PATCH] uml: S390 preparation, abstract host page fault data This patch removes the arch-specific fault/trap-infos from thread and skas-regs. It adds a new struct faultinfo, that is arch-specific defined in sysdep/faultinfo.h. The structure is inserted in thread.arch and thread.regs.skas and thread.regs.tt Now, segv and other trap-handlers can copy the contents from regs.X.faultinfo to thread.arch.faultinfo with one simple assignment. Also, the number of macros necessary is reduced to FAULT_ADDRESS(struct faultinfo) extracts the faulting address from faultinfo FAULT_WRITE(struct faultinfo) extracts the "is_write" flag SEGV_IS_FIXABLE(struct faultinfo) is true for the fixable segvs, i.e. (TRAP == 14) on i386 UPT_FAULTINFO(regs) result is (struct faultinfo *) to the faultinfo in regs->skas.faultinfo GET_FAULTINFO_FROM_SC(struct faultinfo, struct sigcontext *) copies the relevant parts of the sigcontext to struct faultinfo. On SIGSEGV, call user_signal() instead of handle_segv(), if the architecture provides the information needed in PTRACE_FAULTINFO, or if PTRACE_FAULTINFO is missing, because segv-stub will provide the info. The benefit of the change is, that in case of a non-fixable SIGSEGV, we can give user processes a SIGSEGV, instead of possibly looping on pagefault handling. Since handle_segv() sikked arch_fixup() implicitly by passing ip==0 to segv(), I changed segv() to call arch_fixup() only, if !is_user. Signed-off-by: Bodo Stroesser <bstroesser@fujitsu-siemens.com> Signed-off-by: Jeff Dike <jdike@addtoit.com> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2005-05-05 19:15:31 -04:00
/*
* We give a *copy* of the faultinfo in the regs to segv.
* This must be done, since nesting SEGVs could overwrite
* the info in the regs. A pointer to the info then would
* give us bad data!
*/
unsigned long segv(struct faultinfo fi, unsigned long ip, int is_user, void *sc)
{
struct siginfo si;
void *catcher;
int err;
[PATCH] uml: S390 preparation, abstract host page fault data This patch removes the arch-specific fault/trap-infos from thread and skas-regs. It adds a new struct faultinfo, that is arch-specific defined in sysdep/faultinfo.h. The structure is inserted in thread.arch and thread.regs.skas and thread.regs.tt Now, segv and other trap-handlers can copy the contents from regs.X.faultinfo to thread.arch.faultinfo with one simple assignment. Also, the number of macros necessary is reduced to FAULT_ADDRESS(struct faultinfo) extracts the faulting address from faultinfo FAULT_WRITE(struct faultinfo) extracts the "is_write" flag SEGV_IS_FIXABLE(struct faultinfo) is true for the fixable segvs, i.e. (TRAP == 14) on i386 UPT_FAULTINFO(regs) result is (struct faultinfo *) to the faultinfo in regs->skas.faultinfo GET_FAULTINFO_FROM_SC(struct faultinfo, struct sigcontext *) copies the relevant parts of the sigcontext to struct faultinfo. On SIGSEGV, call user_signal() instead of handle_segv(), if the architecture provides the information needed in PTRACE_FAULTINFO, or if PTRACE_FAULTINFO is missing, because segv-stub will provide the info. The benefit of the change is, that in case of a non-fixable SIGSEGV, we can give user processes a SIGSEGV, instead of possibly looping on pagefault handling. Since handle_segv() sikked arch_fixup() implicitly by passing ip==0 to segv(), I changed segv() to call arch_fixup() only, if !is_user. Signed-off-by: Bodo Stroesser <bstroesser@fujitsu-siemens.com> Signed-off-by: Jeff Dike <jdike@addtoit.com> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2005-05-05 19:15:31 -04:00
int is_write = FAULT_WRITE(fi);
unsigned long address = FAULT_ADDRESS(fi);
if(!is_user && (address >= start_vm) && (address < end_vm)){
flush_tlb_kernel_vm();
return(0);
}
else if(current->mm == NULL)
panic("Segfault with no mm");
if (SEGV_IS_FIXABLE(&fi) || SEGV_MAYBE_FIXABLE(&fi))
err = handle_page_fault(address, ip, is_write, is_user, &si.si_code);
else {
err = -EFAULT;
/* A thread accessed NULL, we get a fault, but CR2 is invalid.
* This code is used in __do_copy_from_user() of TT mode. */
address = 0;
}
catcher = current->thread.fault_catcher;
if(!err)
return(0);
else if(catcher != NULL){
current->thread.fault_addr = (void *) address;
do_longjmp(catcher, 1);
}
else if(current->thread.fault_addr != NULL)
panic("fault_addr set but no fault catcher");
[PATCH] uml: S390 preparation, abstract host page fault data This patch removes the arch-specific fault/trap-infos from thread and skas-regs. It adds a new struct faultinfo, that is arch-specific defined in sysdep/faultinfo.h. The structure is inserted in thread.arch and thread.regs.skas and thread.regs.tt Now, segv and other trap-handlers can copy the contents from regs.X.faultinfo to thread.arch.faultinfo with one simple assignment. Also, the number of macros necessary is reduced to FAULT_ADDRESS(struct faultinfo) extracts the faulting address from faultinfo FAULT_WRITE(struct faultinfo) extracts the "is_write" flag SEGV_IS_FIXABLE(struct faultinfo) is true for the fixable segvs, i.e. (TRAP == 14) on i386 UPT_FAULTINFO(regs) result is (struct faultinfo *) to the faultinfo in regs->skas.faultinfo GET_FAULTINFO_FROM_SC(struct faultinfo, struct sigcontext *) copies the relevant parts of the sigcontext to struct faultinfo. On SIGSEGV, call user_signal() instead of handle_segv(), if the architecture provides the information needed in PTRACE_FAULTINFO, or if PTRACE_FAULTINFO is missing, because segv-stub will provide the info. The benefit of the change is, that in case of a non-fixable SIGSEGV, we can give user processes a SIGSEGV, instead of possibly looping on pagefault handling. Since handle_segv() sikked arch_fixup() implicitly by passing ip==0 to segv(), I changed segv() to call arch_fixup() only, if !is_user. Signed-off-by: Bodo Stroesser <bstroesser@fujitsu-siemens.com> Signed-off-by: Jeff Dike <jdike@addtoit.com> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2005-05-05 19:15:31 -04:00
else if(!is_user && arch_fixup(ip, sc))
return(0);
if(!is_user)
panic("Kernel mode fault at addr 0x%lx, ip 0x%lx",
address, ip);
if (err == -EACCES) {
si.si_signo = SIGBUS;
si.si_errno = 0;
si.si_code = BUS_ADRERR;
si.si_addr = (void *)address;
[PATCH] uml: S390 preparation, abstract host page fault data This patch removes the arch-specific fault/trap-infos from thread and skas-regs. It adds a new struct faultinfo, that is arch-specific defined in sysdep/faultinfo.h. The structure is inserted in thread.arch and thread.regs.skas and thread.regs.tt Now, segv and other trap-handlers can copy the contents from regs.X.faultinfo to thread.arch.faultinfo with one simple assignment. Also, the number of macros necessary is reduced to FAULT_ADDRESS(struct faultinfo) extracts the faulting address from faultinfo FAULT_WRITE(struct faultinfo) extracts the "is_write" flag SEGV_IS_FIXABLE(struct faultinfo) is true for the fixable segvs, i.e. (TRAP == 14) on i386 UPT_FAULTINFO(regs) result is (struct faultinfo *) to the faultinfo in regs->skas.faultinfo GET_FAULTINFO_FROM_SC(struct faultinfo, struct sigcontext *) copies the relevant parts of the sigcontext to struct faultinfo. On SIGSEGV, call user_signal() instead of handle_segv(), if the architecture provides the information needed in PTRACE_FAULTINFO, or if PTRACE_FAULTINFO is missing, because segv-stub will provide the info. The benefit of the change is, that in case of a non-fixable SIGSEGV, we can give user processes a SIGSEGV, instead of possibly looping on pagefault handling. Since handle_segv() sikked arch_fixup() implicitly by passing ip==0 to segv(), I changed segv() to call arch_fixup() only, if !is_user. Signed-off-by: Bodo Stroesser <bstroesser@fujitsu-siemens.com> Signed-off-by: Jeff Dike <jdike@addtoit.com> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2005-05-05 19:15:31 -04:00
current->thread.arch.faultinfo = fi;
force_sig_info(SIGBUS, &si, current);
} else if (err == -ENOMEM) {
printk("VM: killing process %s\n", current->comm);
do_exit(SIGKILL);
} else {
BUG_ON(err != -EFAULT);
si.si_signo = SIGSEGV;
si.si_addr = (void *) address;
[PATCH] uml: S390 preparation, abstract host page fault data This patch removes the arch-specific fault/trap-infos from thread and skas-regs. It adds a new struct faultinfo, that is arch-specific defined in sysdep/faultinfo.h. The structure is inserted in thread.arch and thread.regs.skas and thread.regs.tt Now, segv and other trap-handlers can copy the contents from regs.X.faultinfo to thread.arch.faultinfo with one simple assignment. Also, the number of macros necessary is reduced to FAULT_ADDRESS(struct faultinfo) extracts the faulting address from faultinfo FAULT_WRITE(struct faultinfo) extracts the "is_write" flag SEGV_IS_FIXABLE(struct faultinfo) is true for the fixable segvs, i.e. (TRAP == 14) on i386 UPT_FAULTINFO(regs) result is (struct faultinfo *) to the faultinfo in regs->skas.faultinfo GET_FAULTINFO_FROM_SC(struct faultinfo, struct sigcontext *) copies the relevant parts of the sigcontext to struct faultinfo. On SIGSEGV, call user_signal() instead of handle_segv(), if the architecture provides the information needed in PTRACE_FAULTINFO, or if PTRACE_FAULTINFO is missing, because segv-stub will provide the info. The benefit of the change is, that in case of a non-fixable SIGSEGV, we can give user processes a SIGSEGV, instead of possibly looping on pagefault handling. Since handle_segv() sikked arch_fixup() implicitly by passing ip==0 to segv(), I changed segv() to call arch_fixup() only, if !is_user. Signed-off-by: Bodo Stroesser <bstroesser@fujitsu-siemens.com> Signed-off-by: Jeff Dike <jdike@addtoit.com> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2005-05-05 19:15:31 -04:00
current->thread.arch.faultinfo = fi;
force_sig_info(SIGSEGV, &si, current);
}
return(0);
}
[PATCH] uml: S390 preparation, abstract host page fault data This patch removes the arch-specific fault/trap-infos from thread and skas-regs. It adds a new struct faultinfo, that is arch-specific defined in sysdep/faultinfo.h. The structure is inserted in thread.arch and thread.regs.skas and thread.regs.tt Now, segv and other trap-handlers can copy the contents from regs.X.faultinfo to thread.arch.faultinfo with one simple assignment. Also, the number of macros necessary is reduced to FAULT_ADDRESS(struct faultinfo) extracts the faulting address from faultinfo FAULT_WRITE(struct faultinfo) extracts the "is_write" flag SEGV_IS_FIXABLE(struct faultinfo) is true for the fixable segvs, i.e. (TRAP == 14) on i386 UPT_FAULTINFO(regs) result is (struct faultinfo *) to the faultinfo in regs->skas.faultinfo GET_FAULTINFO_FROM_SC(struct faultinfo, struct sigcontext *) copies the relevant parts of the sigcontext to struct faultinfo. On SIGSEGV, call user_signal() instead of handle_segv(), if the architecture provides the information needed in PTRACE_FAULTINFO, or if PTRACE_FAULTINFO is missing, because segv-stub will provide the info. The benefit of the change is, that in case of a non-fixable SIGSEGV, we can give user processes a SIGSEGV, instead of possibly looping on pagefault handling. Since handle_segv() sikked arch_fixup() implicitly by passing ip==0 to segv(), I changed segv() to call arch_fixup() only, if !is_user. Signed-off-by: Bodo Stroesser <bstroesser@fujitsu-siemens.com> Signed-off-by: Jeff Dike <jdike@addtoit.com> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2005-05-05 19:15:31 -04:00
void bad_segv(struct faultinfo fi, unsigned long ip)
{
struct siginfo si;
si.si_signo = SIGSEGV;
si.si_code = SEGV_ACCERR;
[PATCH] uml: S390 preparation, abstract host page fault data This patch removes the arch-specific fault/trap-infos from thread and skas-regs. It adds a new struct faultinfo, that is arch-specific defined in sysdep/faultinfo.h. The structure is inserted in thread.arch and thread.regs.skas and thread.regs.tt Now, segv and other trap-handlers can copy the contents from regs.X.faultinfo to thread.arch.faultinfo with one simple assignment. Also, the number of macros necessary is reduced to FAULT_ADDRESS(struct faultinfo) extracts the faulting address from faultinfo FAULT_WRITE(struct faultinfo) extracts the "is_write" flag SEGV_IS_FIXABLE(struct faultinfo) is true for the fixable segvs, i.e. (TRAP == 14) on i386 UPT_FAULTINFO(regs) result is (struct faultinfo *) to the faultinfo in regs->skas.faultinfo GET_FAULTINFO_FROM_SC(struct faultinfo, struct sigcontext *) copies the relevant parts of the sigcontext to struct faultinfo. On SIGSEGV, call user_signal() instead of handle_segv(), if the architecture provides the information needed in PTRACE_FAULTINFO, or if PTRACE_FAULTINFO is missing, because segv-stub will provide the info. The benefit of the change is, that in case of a non-fixable SIGSEGV, we can give user processes a SIGSEGV, instead of possibly looping on pagefault handling. Since handle_segv() sikked arch_fixup() implicitly by passing ip==0 to segv(), I changed segv() to call arch_fixup() only, if !is_user. Signed-off-by: Bodo Stroesser <bstroesser@fujitsu-siemens.com> Signed-off-by: Jeff Dike <jdike@addtoit.com> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2005-05-05 19:15:31 -04:00
si.si_addr = (void *) FAULT_ADDRESS(fi);
current->thread.arch.faultinfo = fi;
force_sig_info(SIGSEGV, &si, current);
}
void relay_signal(int sig, union uml_pt_regs *regs)
{
if(arch_handle_signal(sig, regs)) return;
if(!UPT_IS_USER(regs))
panic("Kernel mode signal %d", sig);
[PATCH] uml: S390 preparation, abstract host page fault data This patch removes the arch-specific fault/trap-infos from thread and skas-regs. It adds a new struct faultinfo, that is arch-specific defined in sysdep/faultinfo.h. The structure is inserted in thread.arch and thread.regs.skas and thread.regs.tt Now, segv and other trap-handlers can copy the contents from regs.X.faultinfo to thread.arch.faultinfo with one simple assignment. Also, the number of macros necessary is reduced to FAULT_ADDRESS(struct faultinfo) extracts the faulting address from faultinfo FAULT_WRITE(struct faultinfo) extracts the "is_write" flag SEGV_IS_FIXABLE(struct faultinfo) is true for the fixable segvs, i.e. (TRAP == 14) on i386 UPT_FAULTINFO(regs) result is (struct faultinfo *) to the faultinfo in regs->skas.faultinfo GET_FAULTINFO_FROM_SC(struct faultinfo, struct sigcontext *) copies the relevant parts of the sigcontext to struct faultinfo. On SIGSEGV, call user_signal() instead of handle_segv(), if the architecture provides the information needed in PTRACE_FAULTINFO, or if PTRACE_FAULTINFO is missing, because segv-stub will provide the info. The benefit of the change is, that in case of a non-fixable SIGSEGV, we can give user processes a SIGSEGV, instead of possibly looping on pagefault handling. Since handle_segv() sikked arch_fixup() implicitly by passing ip==0 to segv(), I changed segv() to call arch_fixup() only, if !is_user. Signed-off-by: Bodo Stroesser <bstroesser@fujitsu-siemens.com> Signed-off-by: Jeff Dike <jdike@addtoit.com> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2005-05-05 19:15:31 -04:00
current->thread.arch.faultinfo = *UPT_FAULTINFO(regs);
force_sig(sig, current);
}
void bus_handler(int sig, union uml_pt_regs *regs)
{
if(current->thread.fault_catcher != NULL)
do_longjmp(current->thread.fault_catcher, 1);
else relay_signal(sig, regs);
}
void winch(int sig, union uml_pt_regs *regs)
{
do_IRQ(WINCH_IRQ, regs);
}
void trap_init(void)
{
}