android_kernel_xiaomi_sm8350/fs/fs-writeback.c

1279 lines
33 KiB
C
Raw Normal View History

/*
* fs/fs-writeback.c
*
* Copyright (C) 2002, Linus Torvalds.
*
* Contains all the functions related to writing back and waiting
* upon dirty inodes against superblocks, and writing back dirty
* pages against inodes. ie: data writeback. Writeout of the
* inode itself is not handled here.
*
* 10Apr2002 Andrew Morton
* Split out of fs/inode.c
* Additions for address_space-based writeback
*/
#include <linux/kernel.h>
#include <linux/module.h>
#include <linux/spinlock.h>
#include <linux/sched.h>
#include <linux/fs.h>
#include <linux/mm.h>
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
#include <linux/kthread.h>
#include <linux/freezer.h>
#include <linux/writeback.h>
#include <linux/blkdev.h>
#include <linux/backing-dev.h>
#include <linux/buffer_head.h>
#include "internal.h"
#define inode_to_bdi(inode) ((inode)->i_mapping->backing_dev_info)
/*
* We don't actually have pdflush, but this one is exported though /proc...
*/
int nr_pdflush_threads;
/*
* Passed into wb_writeback(), essentially a subset of writeback_control
*/
struct wb_writeback_args {
long nr_pages;
struct super_block *sb;
enum writeback_sync_modes sync_mode;
int for_kupdate:1;
int range_cyclic:1;
int for_background:1;
};
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
/*
* Work items for the bdi_writeback threads
*/
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
struct bdi_work {
struct list_head list; /* pending work list */
struct rcu_head rcu_head; /* for RCU free/clear of work */
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
unsigned long seen; /* threads that have seen this work */
atomic_t pending; /* number of threads still to do work */
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
struct wb_writeback_args args; /* writeback arguments */
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
unsigned long state; /* flag bits, see WS_* */
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
};
enum {
WS_USED_B = 0,
WS_ONSTACK_B,
};
#define WS_USED (1 << WS_USED_B)
#define WS_ONSTACK (1 << WS_ONSTACK_B)
static inline bool bdi_work_on_stack(struct bdi_work *work)
{
return test_bit(WS_ONSTACK_B, &work->state);
}
static inline void bdi_work_init(struct bdi_work *work,
struct wb_writeback_args *args)
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
{
INIT_RCU_HEAD(&work->rcu_head);
work->args = *args;
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
work->state = WS_USED;
}
/**
* writeback_in_progress - determine whether there is writeback in progress
* @bdi: the device's backing_dev_info structure.
*
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
* Determine whether there is writeback waiting to be handled against a
* backing device.
*/
int writeback_in_progress(struct backing_dev_info *bdi)
{
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
return !list_empty(&bdi->work_list);
}
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
static void bdi_work_clear(struct bdi_work *work)
{
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
clear_bit(WS_USED_B, &work->state);
smp_mb__after_clear_bit();
/*
* work can have disappeared at this point. bit waitq functions
* should be able to tolerate this, provided bdi_sched_wait does
* not dereference it's pointer argument.
*/
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
wake_up_bit(&work->state, WS_USED_B);
}
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
static void bdi_work_free(struct rcu_head *head)
{
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
struct bdi_work *work = container_of(head, struct bdi_work, rcu_head);
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
if (!bdi_work_on_stack(work))
kfree(work);
else
bdi_work_clear(work);
}
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
static void wb_work_complete(struct bdi_work *work)
{
const enum writeback_sync_modes sync_mode = work->args.sync_mode;
int onstack = bdi_work_on_stack(work);
/*
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
* For allocated work, we can clear the done/seen bit right here.
* For on-stack work, we need to postpone both the clear and free
* to after the RCU grace period, since the stack could be invalidated
* as soon as bdi_work_clear() has done the wakeup.
*/
if (!onstack)
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
bdi_work_clear(work);
if (sync_mode == WB_SYNC_NONE || onstack)
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
call_rcu(&work->rcu_head, bdi_work_free);
}
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
static void wb_clear_pending(struct bdi_writeback *wb, struct bdi_work *work)
{
/*
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
* The caller has retrieved the work arguments from this work,
* drop our reference. If this is the last ref, delete and free it
*/
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
if (atomic_dec_and_test(&work->pending)) {
struct backing_dev_info *bdi = wb->bdi;
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
spin_lock(&bdi->wb_lock);
list_del_rcu(&work->list);
spin_unlock(&bdi->wb_lock);
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
wb_work_complete(work);
}
}
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
static void bdi_queue_work(struct backing_dev_info *bdi, struct bdi_work *work)
{
work->seen = bdi->wb_mask;
BUG_ON(!work->seen);
atomic_set(&work->pending, bdi->wb_cnt);
BUG_ON(!bdi->wb_cnt);
/*
* list_add_tail_rcu() contains the necessary barriers to
* make sure the above stores are seen before the item is
* noticed on the list
*/
spin_lock(&bdi->wb_lock);
list_add_tail_rcu(&work->list, &bdi->work_list);
spin_unlock(&bdi->wb_lock);
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
/*
* If the default thread isn't there, make sure we add it. When
* it gets created and wakes up, we'll run this work.
*/
if (unlikely(list_empty_careful(&bdi->wb_list)))
wake_up_process(default_backing_dev_info.wb.task);
else {
struct bdi_writeback *wb = &bdi->wb;
if (wb->task)
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
wake_up_process(wb->task);
}
}
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
/*
* Used for on-stack allocated work items. The caller needs to wait until
* the wb threads have acked the work before it's safe to continue.
*/
static void bdi_wait_on_work_clear(struct bdi_work *work)
{
wait_on_bit(&work->state, WS_USED_B, bdi_sched_wait,
TASK_UNINTERRUPTIBLE);
}
static void bdi_alloc_queue_work(struct backing_dev_info *bdi,
struct wb_writeback_args *args)
{
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
struct bdi_work *work;
/*
* This is WB_SYNC_NONE writeback, so if allocation fails just
* wakeup the thread for old dirty data writeback
*/
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
work = kmalloc(sizeof(*work), GFP_ATOMIC);
if (work) {
bdi_work_init(work, args);
bdi_queue_work(bdi, work);
} else {
struct bdi_writeback *wb = &bdi->wb;
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
if (wb->task)
wake_up_process(wb->task);
}
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
}
/**
* bdi_sync_writeback - start and wait for writeback
* @bdi: the backing device to write from
* @sb: write inodes from this super_block
*
* Description:
* This does WB_SYNC_ALL data integrity writeback and waits for the
* IO to complete. Callers must hold the sb s_umount semaphore for
* reading, to avoid having the super disappear before we are done.
*/
static void bdi_sync_writeback(struct backing_dev_info *bdi,
struct super_block *sb)
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
{
struct wb_writeback_args args = {
.sb = sb,
.sync_mode = WB_SYNC_ALL,
.nr_pages = LONG_MAX,
.range_cyclic = 0,
};
struct bdi_work work;
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
bdi_work_init(&work, &args);
work.state |= WS_ONSTACK;
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
bdi_queue_work(bdi, &work);
bdi_wait_on_work_clear(&work);
}
/**
* bdi_start_writeback - start writeback
* @bdi: the backing device to write from
* @sb: write inodes from this super_block
* @nr_pages: the number of pages to write
*
* Description:
* This does WB_SYNC_NONE opportunistic writeback. The IO is only
* started when this function returns, we make no guarentees on
* completion. Caller need not hold sb s_umount semaphore.
*
*/
void bdi_start_writeback(struct backing_dev_info *bdi, struct super_block *sb,
long nr_pages)
{
struct wb_writeback_args args = {
.sb = sb,
.sync_mode = WB_SYNC_NONE,
.nr_pages = nr_pages,
.range_cyclic = 1,
};
/*
* We treat @nr_pages=0 as the special case to do background writeback,
* ie. to sync pages until the background dirty threshold is reached.
*/
if (!nr_pages) {
args.nr_pages = LONG_MAX;
args.for_background = 1;
}
bdi_alloc_queue_work(bdi, &args);
}
/*
* Redirty an inode: set its when-it-was dirtied timestamp and move it to the
* furthest end of its superblock's dirty-inode list.
*
* Before stamping the inode's ->dirtied_when, we check to see whether it is
* already the most-recently-dirtied inode on the b_dirty list. If that is
* the case then the inode must have been redirtied while it was being written
* out and we don't reset its dirtied_when.
*/
static void redirty_tail(struct inode *inode)
{
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
struct bdi_writeback *wb = &inode_to_bdi(inode)->wb;
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
if (!list_empty(&wb->b_dirty)) {
struct inode *tail;
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
tail = list_entry(wb->b_dirty.next, struct inode, i_list);
if (time_before(inode->dirtied_when, tail->dirtied_when))
inode->dirtied_when = jiffies;
}
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
list_move(&inode->i_list, &wb->b_dirty);
}
/*
* requeue inode for re-scanning after bdi->b_io list is exhausted.
*/
static void requeue_io(struct inode *inode)
{
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
struct bdi_writeback *wb = &inode_to_bdi(inode)->wb;
list_move(&inode->i_list, &wb->b_more_io);
}
static void inode_sync_complete(struct inode *inode)
{
/*
* Prevent speculative execution through spin_unlock(&inode_lock);
*/
smp_mb();
wake_up_bit(&inode->i_state, __I_SYNC);
}
writeback: guard against jiffies wraparound on inode->dirtied_when checks (try #3) The dirtied_when value on an inode is supposed to represent the first time that an inode has one of its pages dirtied. This value is in units of jiffies. It's used in several places in the writeback code to determine when to write out an inode. The problem is that these checks assume that dirtied_when is updated periodically. If an inode is continuously being used for I/O it can be persistently marked as dirty and will continue to age. Once the time compared to is greater than or equal to half the maximum of the jiffies type, the logic of the time_*() macros inverts and the opposite of what is needed is returned. On 32-bit architectures that's just under 25 days (assuming HZ == 1000). As the least-recently dirtied inode, it'll end up being the first one that pdflush will try to write out. sync_sb_inodes does this check: /* Was this inode dirtied after sync_sb_inodes was called? */ if (time_after(inode->dirtied_when, start)) break; ...but now dirtied_when appears to be in the future. sync_sb_inodes bails out without attempting to write any dirty inodes. When this occurs, pdflush will stop writing out inodes for this superblock. Nothing can unwedge it until jiffies moves out of the problematic window. This patch fixes this problem by changing the checks against dirtied_when to also check whether it appears to be in the future. If it does, then we consider the value to be far in the past. This should shrink the problematic window of time to such a small period (30s) as not to matter. Signed-off-by: Jeff Layton <jlayton@redhat.com> Signed-off-by: Wu Fengguang <fengguang.wu@intel.com> Acked-by: Ian Kent <raven@themaw.net> Cc: Jens Axboe <jens.axboe@oracle.com> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2009-04-02 19:56:37 -04:00
static bool inode_dirtied_after(struct inode *inode, unsigned long t)
{
bool ret = time_after(inode->dirtied_when, t);
#ifndef CONFIG_64BIT
/*
* For inodes being constantly redirtied, dirtied_when can get stuck.
* It _appears_ to be in the future, but is actually in distant past.
* This test is necessary to prevent such wrapped-around relative times
* from permanently stopping the whole bdi writeback.
writeback: guard against jiffies wraparound on inode->dirtied_when checks (try #3) The dirtied_when value on an inode is supposed to represent the first time that an inode has one of its pages dirtied. This value is in units of jiffies. It's used in several places in the writeback code to determine when to write out an inode. The problem is that these checks assume that dirtied_when is updated periodically. If an inode is continuously being used for I/O it can be persistently marked as dirty and will continue to age. Once the time compared to is greater than or equal to half the maximum of the jiffies type, the logic of the time_*() macros inverts and the opposite of what is needed is returned. On 32-bit architectures that's just under 25 days (assuming HZ == 1000). As the least-recently dirtied inode, it'll end up being the first one that pdflush will try to write out. sync_sb_inodes does this check: /* Was this inode dirtied after sync_sb_inodes was called? */ if (time_after(inode->dirtied_when, start)) break; ...but now dirtied_when appears to be in the future. sync_sb_inodes bails out without attempting to write any dirty inodes. When this occurs, pdflush will stop writing out inodes for this superblock. Nothing can unwedge it until jiffies moves out of the problematic window. This patch fixes this problem by changing the checks against dirtied_when to also check whether it appears to be in the future. If it does, then we consider the value to be far in the past. This should shrink the problematic window of time to such a small period (30s) as not to matter. Signed-off-by: Jeff Layton <jlayton@redhat.com> Signed-off-by: Wu Fengguang <fengguang.wu@intel.com> Acked-by: Ian Kent <raven@themaw.net> Cc: Jens Axboe <jens.axboe@oracle.com> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2009-04-02 19:56:37 -04:00
*/
ret = ret && time_before_eq(inode->dirtied_when, jiffies);
#endif
return ret;
}
/*
* Move expired dirty inodes from @delaying_queue to @dispatch_queue.
*/
static void move_expired_inodes(struct list_head *delaying_queue,
struct list_head *dispatch_queue,
unsigned long *older_than_this)
{
LIST_HEAD(tmp);
struct list_head *pos, *node;
struct super_block *sb = NULL;
struct inode *inode;
int do_sb_sort = 0;
while (!list_empty(delaying_queue)) {
inode = list_entry(delaying_queue->prev, struct inode, i_list);
if (older_than_this &&
writeback: guard against jiffies wraparound on inode->dirtied_when checks (try #3) The dirtied_when value on an inode is supposed to represent the first time that an inode has one of its pages dirtied. This value is in units of jiffies. It's used in several places in the writeback code to determine when to write out an inode. The problem is that these checks assume that dirtied_when is updated periodically. If an inode is continuously being used for I/O it can be persistently marked as dirty and will continue to age. Once the time compared to is greater than or equal to half the maximum of the jiffies type, the logic of the time_*() macros inverts and the opposite of what is needed is returned. On 32-bit architectures that's just under 25 days (assuming HZ == 1000). As the least-recently dirtied inode, it'll end up being the first one that pdflush will try to write out. sync_sb_inodes does this check: /* Was this inode dirtied after sync_sb_inodes was called? */ if (time_after(inode->dirtied_when, start)) break; ...but now dirtied_when appears to be in the future. sync_sb_inodes bails out without attempting to write any dirty inodes. When this occurs, pdflush will stop writing out inodes for this superblock. Nothing can unwedge it until jiffies moves out of the problematic window. This patch fixes this problem by changing the checks against dirtied_when to also check whether it appears to be in the future. If it does, then we consider the value to be far in the past. This should shrink the problematic window of time to such a small period (30s) as not to matter. Signed-off-by: Jeff Layton <jlayton@redhat.com> Signed-off-by: Wu Fengguang <fengguang.wu@intel.com> Acked-by: Ian Kent <raven@themaw.net> Cc: Jens Axboe <jens.axboe@oracle.com> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2009-04-02 19:56:37 -04:00
inode_dirtied_after(inode, *older_than_this))
break;
if (sb && sb != inode->i_sb)
do_sb_sort = 1;
sb = inode->i_sb;
list_move(&inode->i_list, &tmp);
}
/* just one sb in list, splice to dispatch_queue and we're done */
if (!do_sb_sort) {
list_splice(&tmp, dispatch_queue);
return;
}
/* Move inodes from one superblock together */
while (!list_empty(&tmp)) {
inode = list_entry(tmp.prev, struct inode, i_list);
sb = inode->i_sb;
list_for_each_prev_safe(pos, node, &tmp) {
inode = list_entry(pos, struct inode, i_list);
if (inode->i_sb == sb)
list_move(&inode->i_list, dispatch_queue);
}
}
}
/*
* Queue all expired dirty inodes for io, eldest first.
*/
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
static void queue_io(struct bdi_writeback *wb, unsigned long *older_than_this)
{
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
list_splice_init(&wb->b_more_io, wb->b_io.prev);
move_expired_inodes(&wb->b_dirty, &wb->b_io, older_than_this);
}
static int write_inode(struct inode *inode, struct writeback_control *wbc)
{
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
if (inode->i_sb->s_op->write_inode && !is_bad_inode(inode))
return inode->i_sb->s_op->write_inode(inode, wbc);
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
return 0;
}
/*
* Wait for writeback on an inode to complete.
*/
static void inode_wait_for_writeback(struct inode *inode)
{
DEFINE_WAIT_BIT(wq, &inode->i_state, __I_SYNC);
wait_queue_head_t *wqh;
wqh = bit_waitqueue(&inode->i_state, __I_SYNC);
do {
spin_unlock(&inode_lock);
__wait_on_bit(wqh, &wq, inode_wait, TASK_UNINTERRUPTIBLE);
spin_lock(&inode_lock);
} while (inode->i_state & I_SYNC);
}
/*
* Write out an inode's dirty pages. Called under inode_lock. Either the
* caller has ref on the inode (either via __iget or via syscall against an fd)
* or the inode has I_WILL_FREE set (via generic_forget_inode)
*
* If `wait' is set, wait on the writeout.
*
* The whole writeout design is quite complex and fragile. We want to avoid
* starvation of particular inodes when others are being redirtied, prevent
* livelocks, etc.
*
* Called under inode_lock.
*/
static int
writeback_single_inode(struct inode *inode, struct writeback_control *wbc)
{
struct address_space *mapping = inode->i_mapping;
unsigned dirty;
int ret;
if (!atomic_read(&inode->i_count))
WARN_ON(!(inode->i_state & (I_WILL_FREE|I_FREEING)));
else
WARN_ON(inode->i_state & I_WILL_FREE);
if (inode->i_state & I_SYNC) {
/*
* If this inode is locked for writeback and we are not doing
* writeback-for-data-integrity, move it to b_more_io so that
* writeback can proceed with the other inodes on s_io.
*
* We'll have another go at writing back this inode when we
* completed a full scan of b_io.
*/
if (wbc->sync_mode != WB_SYNC_ALL) {
requeue_io(inode);
return 0;
}
/*
* It's a data-integrity sync. We must wait.
*/
inode_wait_for_writeback(inode);
}
BUG_ON(inode->i_state & I_SYNC);
/* Set I_SYNC, reset I_DIRTY */
dirty = inode->i_state & I_DIRTY;
inode->i_state |= I_SYNC;
inode->i_state &= ~I_DIRTY;
spin_unlock(&inode_lock);
ret = do_writepages(mapping, wbc);
/*
* Make sure to wait on the data before writing out the metadata.
* This is important for filesystems that modify metadata on data
* I/O completion.
*/
if (wbc->sync_mode == WB_SYNC_ALL) {
int err = filemap_fdatawait(mapping);
if (ret == 0)
ret = err;
}
/* Don't write the inode if only I_DIRTY_PAGES was set */
if (dirty & (I_DIRTY_SYNC | I_DIRTY_DATASYNC)) {
int err = write_inode(inode, wbc);
if (ret == 0)
ret = err;
}
spin_lock(&inode_lock);
inode->i_state &= ~I_SYNC;
writeback: skip new or to-be-freed inodes 1) I_FREEING tests should be coupled with I_CLEAR The two I_FREEING tests are racy because clear_inode() can set i_state to I_CLEAR between the clear of I_SYNC and the test of I_FREEING. 2) skip I_WILL_FREE inodes in generic_sync_sb_inodes() to avoid possible races with generic_forget_inode() generic_forget_inode() sets I_WILL_FREE call writeback on its own, so generic_sync_sb_inodes() shall not try to step in and create possible races: generic_forget_inode inode->i_state |= I_WILL_FREE; spin_unlock(&inode_lock); generic_sync_sb_inodes() spin_lock(&inode_lock); __iget(inode); __writeback_single_inode // see non zero i_count may WARN here ==> WARN_ON(inode->i_state & I_WILL_FREE); spin_unlock(&inode_lock); may call generic_forget_inode again ==> iput(inode); The above race and warning didn't turn up because writeback_inodes() holds the s_umount lock, so generic_forget_inode() finds MS_ACTIVE and returns early. But we are not sure the UBIFS calls and future callers will guarantee that. So skip I_WILL_FREE inodes for the sake of safety. Cc: Eric Sandeen <sandeen@sandeen.net> Acked-by: Jeff Layton <jlayton@redhat.com> Cc: Masayoshi MIZUMA <m.mizuma@jp.fujitsu.com> Signed-off-by: Wu Fengguang <fengguang.wu@intel.com> Cc: Artem Bityutskiy <dedekind1@gmail.com> Cc: Christoph Hellwig <hch@infradead.org> Acked-by: Jan Kara <jack@suse.cz> Cc: Al Viro <viro@zeniv.linux.org.uk> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2009-06-16 18:33:17 -04:00
if (!(inode->i_state & (I_FREEING | I_CLEAR))) {
if ((inode->i_state & I_DIRTY_PAGES) && wbc->for_kupdate) {
/*
* More pages get dirtied by a fast dirtier.
*/
goto select_queue;
} else if (inode->i_state & I_DIRTY) {
/*
* At least XFS will redirty the inode during the
* writeback (delalloc) and on io completion (isize).
*/
redirty_tail(inode);
} else if (mapping_tagged(mapping, PAGECACHE_TAG_DIRTY)) {
/*
* We didn't write back all the pages. nfs_writepages()
* sometimes bales out without doing anything. Redirty
* the inode; Move it from b_io onto b_more_io/b_dirty.
*/
/*
* akpm: if the caller was the kupdate function we put
* this inode at the head of b_dirty so it gets first
* consideration. Otherwise, move it to the tail, for
* the reasons described there. I'm not really sure
* how much sense this makes. Presumably I had a good
* reasons for doing it this way, and I'd rather not
* muck with it at present.
*/
if (wbc->for_kupdate) {
/*
* For the kupdate function we move the inode
* to b_more_io so it will get more writeout as
* soon as the queue becomes uncongested.
*/
inode->i_state |= I_DIRTY_PAGES;
select_queue:
writeback: speed up writeback of big dirty files After making dirty a 100M file, the normal behavior is to start the writeback for all data after 30s delays. But sometimes the following happens instead: - after 30s: ~4M - after 5s: ~4M - after 5s: all remaining 92M Some analyze shows that the internal io dispatch queues goes like this: s_io s_more_io ------------------------- 1) 100M,1K 0 2) 1K 96M 3) 0 96M 1) initial state with a 100M file and a 1K file 2) 4M written, nr_to_write <= 0, so write more 3) 1K written, nr_to_write > 0, no more writes(BUG) nr_to_write > 0 in (3) fools the upper layer to think that data have all been written out. The big dirty file is actually still sitting in s_more_io. We cannot simply splice s_more_io back to s_io as soon as s_io becomes empty, and let the loop in generic_sync_sb_inodes() continue: this may starve newly expired inodes in s_dirty. It is also not an option to draw inodes from both s_more_io and s_dirty, an let the loop go on: this might lead to live locks, and might also starve other superblocks in sync time(well kupdate may still starve some superblocks, that's another bug). We have to return when a full scan of s_io completes. So nr_to_write > 0 does not necessarily mean that "all data are written". This patch introduces a flag writeback_control.more_io to indicate that more io should be done. With it the big dirty file no longer has to wait for the next kupdate invokation 5s later. In sync_sb_inodes() we only set more_io on super_blocks we actually visited. This avoids the interaction between two pdflush deamons. Also in __sync_single_inode() we don't blindly keep requeuing the io if the filesystem cannot progress. Failing to do so may lead to 100% iowait. Tested-by: Mike Snitzer <snitzer@gmail.com> Signed-off-by: Fengguang Wu <wfg@mail.ustc.edu.cn> Cc: Michael Rubin <mrubin@google.com> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2008-02-05 01:29:36 -05:00
if (wbc->nr_to_write <= 0) {
/*
* slice used up: queue for next turn
*/
requeue_io(inode);
} else {
/*
* somehow blocked: retry later
*/
redirty_tail(inode);
}
} else {
/*
* Otherwise fully redirty the inode so that
* other inodes on this superblock will get some
* writeout. Otherwise heavy writing to one
* file would indefinitely suspend writeout of
* all the other files.
*/
inode->i_state |= I_DIRTY_PAGES;
redirty_tail(inode);
}
} else if (atomic_read(&inode->i_count)) {
/*
* The inode is clean, inuse
*/
list_move(&inode->i_list, &inode_in_use);
} else {
/*
* The inode is clean, unused
*/
list_move(&inode->i_list, &inode_unused);
}
}
inode_sync_complete(inode);
return ret;
}
static void unpin_sb_for_writeback(struct super_block **psb)
{
struct super_block *sb = *psb;
if (sb) {
up_read(&sb->s_umount);
put_super(sb);
*psb = NULL;
}
}
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
/*
* For WB_SYNC_NONE writeback, the caller does not have the sb pinned
* before calling writeback. So make sure that we do pin it, so it doesn't
* go away while we are writing inodes from it.
*
* Returns 0 if the super was successfully pinned (or pinning wasn't needed),
* 1 if we failed.
*/
static int pin_sb_for_writeback(struct writeback_control *wbc,
struct inode *inode, struct super_block **psb)
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
{
struct super_block *sb = inode->i_sb;
/*
* If this sb is already pinned, nothing more to do. If not and
* *psb is non-NULL, unpin the old one first
*/
if (sb == *psb)
return 0;
else if (*psb)
unpin_sb_for_writeback(psb);
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
/*
* Caller must already hold the ref for this
*/
if (wbc->sync_mode == WB_SYNC_ALL) {
WARN_ON(!rwsem_is_locked(&sb->s_umount));
return 0;
}
spin_lock(&sb_lock);
sb->s_count++;
if (down_read_trylock(&sb->s_umount)) {
if (sb->s_root) {
spin_unlock(&sb_lock);
goto pinned;
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
}
/*
* umounted, drop rwsem again and fall through to failure
*/
up_read(&sb->s_umount);
}
sb->s_count--;
spin_unlock(&sb_lock);
return 1;
pinned:
*psb = sb;
return 0;
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
}
static void writeback_inodes_wb(struct bdi_writeback *wb,
struct writeback_control *wbc)
{
struct super_block *sb = wbc->sb, *pin_sb = NULL;
const unsigned long start = jiffies; /* livelock avoidance */
spin_lock(&inode_lock);
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
if (!wbc->for_kupdate || list_empty(&wb->b_io))
queue_io(wb, wbc->older_than_this);
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
while (!list_empty(&wb->b_io)) {
struct inode *inode = list_entry(wb->b_io.prev,
struct inode, i_list);
long pages_skipped;
/*
* super block given and doesn't match, skip this inode
*/
if (sb && sb != inode->i_sb) {
redirty_tail(inode);
continue;
}
writeback: skip new or to-be-freed inodes 1) I_FREEING tests should be coupled with I_CLEAR The two I_FREEING tests are racy because clear_inode() can set i_state to I_CLEAR between the clear of I_SYNC and the test of I_FREEING. 2) skip I_WILL_FREE inodes in generic_sync_sb_inodes() to avoid possible races with generic_forget_inode() generic_forget_inode() sets I_WILL_FREE call writeback on its own, so generic_sync_sb_inodes() shall not try to step in and create possible races: generic_forget_inode inode->i_state |= I_WILL_FREE; spin_unlock(&inode_lock); generic_sync_sb_inodes() spin_lock(&inode_lock); __iget(inode); __writeback_single_inode // see non zero i_count may WARN here ==> WARN_ON(inode->i_state & I_WILL_FREE); spin_unlock(&inode_lock); may call generic_forget_inode again ==> iput(inode); The above race and warning didn't turn up because writeback_inodes() holds the s_umount lock, so generic_forget_inode() finds MS_ACTIVE and returns early. But we are not sure the UBIFS calls and future callers will guarantee that. So skip I_WILL_FREE inodes for the sake of safety. Cc: Eric Sandeen <sandeen@sandeen.net> Acked-by: Jeff Layton <jlayton@redhat.com> Cc: Masayoshi MIZUMA <m.mizuma@jp.fujitsu.com> Signed-off-by: Wu Fengguang <fengguang.wu@intel.com> Cc: Artem Bityutskiy <dedekind1@gmail.com> Cc: Christoph Hellwig <hch@infradead.org> Acked-by: Jan Kara <jack@suse.cz> Cc: Al Viro <viro@zeniv.linux.org.uk> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2009-06-16 18:33:17 -04:00
if (inode->i_state & (I_NEW | I_WILL_FREE)) {
fs: new inode i_state corruption fix There was a report of a data corruption http://lkml.org/lkml/2008/11/14/121. There is a script included to reproduce the problem. During testing, I encountered a number of strange things with ext3, so I tried ext2 to attempt to reduce complexity of the problem. I found that fsstress would quickly hang in wait_on_inode, waiting for I_LOCK to be cleared, even though instrumentation showed that unlock_new_inode had already been called for that inode. This points to memory scribble, or synchronisation problme. i_state of I_NEW inodes is not protected by inode_lock because other processes are not supposed to touch them until I_LOCK (and I_NEW) is cleared. Adding WARN_ON(inode->i_state & I_NEW) to sites where we modify i_state revealed that generic_sync_sb_inodes is picking up new inodes from the inode lists and passing them to __writeback_single_inode without waiting for I_NEW. Subsequently modifying i_state causes corruption. In my case it would look like this: CPU0 CPU1 unlock_new_inode() __sync_single_inode() reg <- inode->i_state reg -> reg & ~(I_LOCK|I_NEW) reg <- inode->i_state reg -> inode->i_state reg -> reg | I_SYNC reg -> inode->i_state Non-atomic RMW on CPU1 overwrites CPU0 store and sets I_LOCK|I_NEW again. Fix for this is rather than wait for I_NEW inodes, just skip over them: inodes concurrently being created are not subject to data integrity operations, and should not significantly contribute to dirty memory either. After this change, I'm unable to reproduce any of the added warnings or hangs after ~1hour of running. Previously, the new warnings would start immediately and hang would happen in under 5 minutes. I'm also testing on ext3 now, and so far no problems there either. I don't know whether this fixes the problem reported above, but it fixes a real problem for me. Cc: "Jorge Boncompte [DTI2]" <jorge@dti2.net> Reported-by: Adrian Hunter <ext-adrian.hunter@nokia.com> Cc: Jan Kara <jack@suse.cz> Cc: <stable@kernel.org> Signed-off-by: Nick Piggin <npiggin@suse.de> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2009-03-12 17:31:38 -04:00
requeue_io(inode);
continue;
}
writeback: guard against jiffies wraparound on inode->dirtied_when checks (try #3) The dirtied_when value on an inode is supposed to represent the first time that an inode has one of its pages dirtied. This value is in units of jiffies. It's used in several places in the writeback code to determine when to write out an inode. The problem is that these checks assume that dirtied_when is updated periodically. If an inode is continuously being used for I/O it can be persistently marked as dirty and will continue to age. Once the time compared to is greater than or equal to half the maximum of the jiffies type, the logic of the time_*() macros inverts and the opposite of what is needed is returned. On 32-bit architectures that's just under 25 days (assuming HZ == 1000). As the least-recently dirtied inode, it'll end up being the first one that pdflush will try to write out. sync_sb_inodes does this check: /* Was this inode dirtied after sync_sb_inodes was called? */ if (time_after(inode->dirtied_when, start)) break; ...but now dirtied_when appears to be in the future. sync_sb_inodes bails out without attempting to write any dirty inodes. When this occurs, pdflush will stop writing out inodes for this superblock. Nothing can unwedge it until jiffies moves out of the problematic window. This patch fixes this problem by changing the checks against dirtied_when to also check whether it appears to be in the future. If it does, then we consider the value to be far in the past. This should shrink the problematic window of time to such a small period (30s) as not to matter. Signed-off-by: Jeff Layton <jlayton@redhat.com> Signed-off-by: Wu Fengguang <fengguang.wu@intel.com> Acked-by: Ian Kent <raven@themaw.net> Cc: Jens Axboe <jens.axboe@oracle.com> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2009-04-02 19:56:37 -04:00
/*
* Was this inode dirtied after sync_sb_inodes was called?
* This keeps sync from extra jobs and livelock.
*/
if (inode_dirtied_after(inode, start))
break;
if (pin_sb_for_writeback(wbc, inode, &pin_sb)) {
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
requeue_io(inode);
continue;
}
writeback: skip new or to-be-freed inodes 1) I_FREEING tests should be coupled with I_CLEAR The two I_FREEING tests are racy because clear_inode() can set i_state to I_CLEAR between the clear of I_SYNC and the test of I_FREEING. 2) skip I_WILL_FREE inodes in generic_sync_sb_inodes() to avoid possible races with generic_forget_inode() generic_forget_inode() sets I_WILL_FREE call writeback on its own, so generic_sync_sb_inodes() shall not try to step in and create possible races: generic_forget_inode inode->i_state |= I_WILL_FREE; spin_unlock(&inode_lock); generic_sync_sb_inodes() spin_lock(&inode_lock); __iget(inode); __writeback_single_inode // see non zero i_count may WARN here ==> WARN_ON(inode->i_state & I_WILL_FREE); spin_unlock(&inode_lock); may call generic_forget_inode again ==> iput(inode); The above race and warning didn't turn up because writeback_inodes() holds the s_umount lock, so generic_forget_inode() finds MS_ACTIVE and returns early. But we are not sure the UBIFS calls and future callers will guarantee that. So skip I_WILL_FREE inodes for the sake of safety. Cc: Eric Sandeen <sandeen@sandeen.net> Acked-by: Jeff Layton <jlayton@redhat.com> Cc: Masayoshi MIZUMA <m.mizuma@jp.fujitsu.com> Signed-off-by: Wu Fengguang <fengguang.wu@intel.com> Cc: Artem Bityutskiy <dedekind1@gmail.com> Cc: Christoph Hellwig <hch@infradead.org> Acked-by: Jan Kara <jack@suse.cz> Cc: Al Viro <viro@zeniv.linux.org.uk> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2009-06-16 18:33:17 -04:00
BUG_ON(inode->i_state & (I_FREEING | I_CLEAR));
__iget(inode);
pages_skipped = wbc->pages_skipped;
writeback_single_inode(inode, wbc);
if (wbc->pages_skipped != pages_skipped) {
/*
* writeback is not making progress due to locked
* buffers. Skip this inode for now.
*/
redirty_tail(inode);
}
spin_unlock(&inode_lock);
iput(inode);
cond_resched();
spin_lock(&inode_lock);
writeback: speed up writeback of big dirty files After making dirty a 100M file, the normal behavior is to start the writeback for all data after 30s delays. But sometimes the following happens instead: - after 30s: ~4M - after 5s: ~4M - after 5s: all remaining 92M Some analyze shows that the internal io dispatch queues goes like this: s_io s_more_io ------------------------- 1) 100M,1K 0 2) 1K 96M 3) 0 96M 1) initial state with a 100M file and a 1K file 2) 4M written, nr_to_write <= 0, so write more 3) 1K written, nr_to_write > 0, no more writes(BUG) nr_to_write > 0 in (3) fools the upper layer to think that data have all been written out. The big dirty file is actually still sitting in s_more_io. We cannot simply splice s_more_io back to s_io as soon as s_io becomes empty, and let the loop in generic_sync_sb_inodes() continue: this may starve newly expired inodes in s_dirty. It is also not an option to draw inodes from both s_more_io and s_dirty, an let the loop go on: this might lead to live locks, and might also starve other superblocks in sync time(well kupdate may still starve some superblocks, that's another bug). We have to return when a full scan of s_io completes. So nr_to_write > 0 does not necessarily mean that "all data are written". This patch introduces a flag writeback_control.more_io to indicate that more io should be done. With it the big dirty file no longer has to wait for the next kupdate invokation 5s later. In sync_sb_inodes() we only set more_io on super_blocks we actually visited. This avoids the interaction between two pdflush deamons. Also in __sync_single_inode() we don't blindly keep requeuing the io if the filesystem cannot progress. Failing to do so may lead to 100% iowait. Tested-by: Mike Snitzer <snitzer@gmail.com> Signed-off-by: Fengguang Wu <wfg@mail.ustc.edu.cn> Cc: Michael Rubin <mrubin@google.com> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2008-02-05 01:29:36 -05:00
if (wbc->nr_to_write <= 0) {
wbc->more_io = 1;
break;
writeback: speed up writeback of big dirty files After making dirty a 100M file, the normal behavior is to start the writeback for all data after 30s delays. But sometimes the following happens instead: - after 30s: ~4M - after 5s: ~4M - after 5s: all remaining 92M Some analyze shows that the internal io dispatch queues goes like this: s_io s_more_io ------------------------- 1) 100M,1K 0 2) 1K 96M 3) 0 96M 1) initial state with a 100M file and a 1K file 2) 4M written, nr_to_write <= 0, so write more 3) 1K written, nr_to_write > 0, no more writes(BUG) nr_to_write > 0 in (3) fools the upper layer to think that data have all been written out. The big dirty file is actually still sitting in s_more_io. We cannot simply splice s_more_io back to s_io as soon as s_io becomes empty, and let the loop in generic_sync_sb_inodes() continue: this may starve newly expired inodes in s_dirty. It is also not an option to draw inodes from both s_more_io and s_dirty, an let the loop go on: this might lead to live locks, and might also starve other superblocks in sync time(well kupdate may still starve some superblocks, that's another bug). We have to return when a full scan of s_io completes. So nr_to_write > 0 does not necessarily mean that "all data are written". This patch introduces a flag writeback_control.more_io to indicate that more io should be done. With it the big dirty file no longer has to wait for the next kupdate invokation 5s later. In sync_sb_inodes() we only set more_io on super_blocks we actually visited. This avoids the interaction between two pdflush deamons. Also in __sync_single_inode() we don't blindly keep requeuing the io if the filesystem cannot progress. Failing to do so may lead to 100% iowait. Tested-by: Mike Snitzer <snitzer@gmail.com> Signed-off-by: Fengguang Wu <wfg@mail.ustc.edu.cn> Cc: Michael Rubin <mrubin@google.com> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2008-02-05 01:29:36 -05:00
}
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
if (!list_empty(&wb->b_more_io))
writeback: speed up writeback of big dirty files After making dirty a 100M file, the normal behavior is to start the writeback for all data after 30s delays. But sometimes the following happens instead: - after 30s: ~4M - after 5s: ~4M - after 5s: all remaining 92M Some analyze shows that the internal io dispatch queues goes like this: s_io s_more_io ------------------------- 1) 100M,1K 0 2) 1K 96M 3) 0 96M 1) initial state with a 100M file and a 1K file 2) 4M written, nr_to_write <= 0, so write more 3) 1K written, nr_to_write > 0, no more writes(BUG) nr_to_write > 0 in (3) fools the upper layer to think that data have all been written out. The big dirty file is actually still sitting in s_more_io. We cannot simply splice s_more_io back to s_io as soon as s_io becomes empty, and let the loop in generic_sync_sb_inodes() continue: this may starve newly expired inodes in s_dirty. It is also not an option to draw inodes from both s_more_io and s_dirty, an let the loop go on: this might lead to live locks, and might also starve other superblocks in sync time(well kupdate may still starve some superblocks, that's another bug). We have to return when a full scan of s_io completes. So nr_to_write > 0 does not necessarily mean that "all data are written". This patch introduces a flag writeback_control.more_io to indicate that more io should be done. With it the big dirty file no longer has to wait for the next kupdate invokation 5s later. In sync_sb_inodes() we only set more_io on super_blocks we actually visited. This avoids the interaction between two pdflush deamons. Also in __sync_single_inode() we don't blindly keep requeuing the io if the filesystem cannot progress. Failing to do so may lead to 100% iowait. Tested-by: Mike Snitzer <snitzer@gmail.com> Signed-off-by: Fengguang Wu <wfg@mail.ustc.edu.cn> Cc: Michael Rubin <mrubin@google.com> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2008-02-05 01:29:36 -05:00
wbc->more_io = 1;
}
unpin_sb_for_writeback(&pin_sb);
spin_unlock(&inode_lock);
/* Leave any unwritten inodes on b_io */
}
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
void writeback_inodes_wbc(struct writeback_control *wbc)
{
struct backing_dev_info *bdi = wbc->bdi;
writeback_inodes_wb(&bdi->wb, wbc);
}
/*
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
* The maximum number of pages to writeout in a single bdi flush/kupdate
* operation. We do this so we don't hold I_SYNC against an inode for
* enormous amounts of time, which would block a userspace task which has
* been forced to throttle against that inode. Also, the code reevaluates
* the dirty each time it has written this many pages.
*/
#define MAX_WRITEBACK_PAGES 1024
static inline bool over_bground_thresh(void)
{
unsigned long background_thresh, dirty_thresh;
get_dirty_limits(&background_thresh, &dirty_thresh, NULL, NULL);
return (global_page_state(NR_FILE_DIRTY) +
global_page_state(NR_UNSTABLE_NFS) >= background_thresh);
}
/*
* Explicit flushing or periodic writeback of "old" data.
*
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
* Define "old": the first time one of an inode's pages is dirtied, we mark the
* dirtying-time in the inode's address_space. So this periodic writeback code
* just walks the superblock inode list, writing back any inodes which are
* older than a specific point in time.
*
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
* Try to run once per dirty_writeback_interval. But if a writeback event
* takes longer than a dirty_writeback_interval interval, then leave a
* one-second gap.
*
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
* older_than_this takes precedence over nr_to_write. So we'll only write back
* all dirty pages if they are all attached to "old" mappings.
*/
static long wb_writeback(struct bdi_writeback *wb,
struct wb_writeback_args *args)
{
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
struct writeback_control wbc = {
.bdi = wb->bdi,
.sb = args->sb,
.sync_mode = args->sync_mode,
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
.older_than_this = NULL,
.for_kupdate = args->for_kupdate,
.for_background = args->for_background,
.range_cyclic = args->range_cyclic,
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
};
unsigned long oldest_jif;
long wrote = 0;
struct inode *inode;
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
if (wbc.for_kupdate) {
wbc.older_than_this = &oldest_jif;
oldest_jif = jiffies -
msecs_to_jiffies(dirty_expire_interval * 10);
}
if (!wbc.range_cyclic) {
wbc.range_start = 0;
wbc.range_end = LLONG_MAX;
}
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
for (;;) {
/*
* Stop writeback when nr_pages has been consumed
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
*/
if (args->nr_pages <= 0)
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
break;
/*
* For background writeout, stop when we are below the
* background dirty threshold
*/
if (args->for_background && !over_bground_thresh())
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
break;
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
wbc.more_io = 0;
wbc.nr_to_write = MAX_WRITEBACK_PAGES;
wbc.pages_skipped = 0;
writeback_inodes_wb(wb, &wbc);
args->nr_pages -= MAX_WRITEBACK_PAGES - wbc.nr_to_write;
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
wrote += MAX_WRITEBACK_PAGES - wbc.nr_to_write;
/*
* If we consumed everything, see if we have more
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
*/
if (wbc.nr_to_write <= 0)
continue;
/*
* Didn't write everything and we don't have more IO, bail
*/
if (!wbc.more_io)
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
break;
/*
* Did we write something? Try for more
*/
if (wbc.nr_to_write < MAX_WRITEBACK_PAGES)
continue;
/*
* Nothing written. Wait for some inode to
* become available for writeback. Otherwise
* we'll just busyloop.
*/
spin_lock(&inode_lock);
if (!list_empty(&wb->b_more_io)) {
inode = list_entry(wb->b_more_io.prev,
struct inode, i_list);
inode_wait_for_writeback(inode);
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
}
spin_unlock(&inode_lock);
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
}
return wrote;
}
/*
* Return the next bdi_work struct that hasn't been processed by this
* wb thread yet. ->seen is initially set for each thread that exists
* for this device, when a thread first notices a piece of work it
* clears its bit. Depending on writeback type, the thread will notify
* completion on either receiving the work (WB_SYNC_NONE) or after
* it is done (WB_SYNC_ALL).
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
*/
static struct bdi_work *get_next_work_item(struct backing_dev_info *bdi,
struct bdi_writeback *wb)
{
struct bdi_work *work, *ret = NULL;
rcu_read_lock();
list_for_each_entry_rcu(work, &bdi->work_list, list) {
if (!test_bit(wb->nr, &work->seen))
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
continue;
clear_bit(wb->nr, &work->seen);
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
ret = work;
break;
}
rcu_read_unlock();
return ret;
}
static long wb_check_old_data_flush(struct bdi_writeback *wb)
{
unsigned long expired;
long nr_pages;
expired = wb->last_old_flush +
msecs_to_jiffies(dirty_writeback_interval * 10);
if (time_before(jiffies, expired))
return 0;
wb->last_old_flush = jiffies;
nr_pages = global_page_state(NR_FILE_DIRTY) +
global_page_state(NR_UNSTABLE_NFS) +
(inodes_stat.nr_inodes - inodes_stat.nr_unused);
if (nr_pages) {
struct wb_writeback_args args = {
.nr_pages = nr_pages,
.sync_mode = WB_SYNC_NONE,
.for_kupdate = 1,
.range_cyclic = 1,
};
return wb_writeback(wb, &args);
}
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
return 0;
}
/*
* Retrieve work items and do the writeback they describe
*/
long wb_do_writeback(struct bdi_writeback *wb, int force_wait)
{
struct backing_dev_info *bdi = wb->bdi;
struct bdi_work *work;
long wrote = 0;
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
while ((work = get_next_work_item(bdi, wb)) != NULL) {
struct wb_writeback_args args = work->args;
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
/*
* Override sync mode, in case we must wait for completion
*/
if (force_wait)
work->args.sync_mode = args.sync_mode = WB_SYNC_ALL;
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
/*
* If this isn't a data integrity operation, just notify
* that we have seen this work and we are now starting it.
*/
if (args.sync_mode == WB_SYNC_NONE)
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
wb_clear_pending(wb, work);
wrote += wb_writeback(wb, &args);
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
/*
* This is a data integrity writeback, so only do the
* notification when we have completed the work.
*/
if (args.sync_mode == WB_SYNC_ALL)
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
wb_clear_pending(wb, work);
}
/*
* Check for periodic writeback, kupdated() style
*/
wrote += wb_check_old_data_flush(wb);
return wrote;
}
/*
* Handle writeback of dirty data for the device backed by this bdi. Also
* wakes up periodically and does kupdated style flushing.
*/
int bdi_writeback_task(struct bdi_writeback *wb)
{
unsigned long last_active = jiffies;
unsigned long wait_jiffies = -1UL;
long pages_written;
while (!kthread_should_stop()) {
pages_written = wb_do_writeback(wb, 0);
if (pages_written)
last_active = jiffies;
else if (wait_jiffies != -1UL) {
unsigned long max_idle;
/*
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
* Longest period of inactivity that we tolerate. If we
* see dirty data again later, the task will get
* recreated automatically.
*/
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
max_idle = max(5UL * 60 * HZ, wait_jiffies);
if (time_after(jiffies, max_idle + last_active))
break;
}
wait_jiffies = msecs_to_jiffies(dirty_writeback_interval * 10);
schedule_timeout_interruptible(wait_jiffies);
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
try_to_freeze();
}
return 0;
}
/*
* Schedule writeback for all backing devices. This does WB_SYNC_NONE
* writeback, for integrity writeback see bdi_sync_writeback().
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
*/
static void bdi_writeback_all(struct super_block *sb, long nr_pages)
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
{
struct wb_writeback_args args = {
.sb = sb,
.nr_pages = nr_pages,
.sync_mode = WB_SYNC_NONE,
};
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
struct backing_dev_info *bdi;
rcu_read_lock();
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
list_for_each_entry_rcu(bdi, &bdi_list, bdi_list) {
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
if (!bdi_has_dirty_io(bdi))
continue;
bdi_alloc_queue_work(bdi, &args);
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
}
rcu_read_unlock();
}
/*
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
* Start writeback of `nr_pages' pages. If `nr_pages' is zero, write back
* the whole world.
*/
void wakeup_flusher_threads(long nr_pages)
{
if (nr_pages == 0)
nr_pages = global_page_state(NR_FILE_DIRTY) +
global_page_state(NR_UNSTABLE_NFS);
bdi_writeback_all(NULL, nr_pages);
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
}
static noinline void block_dump___mark_inode_dirty(struct inode *inode)
{
if (inode->i_ino || strcmp(inode->i_sb->s_id, "bdev")) {
struct dentry *dentry;
const char *name = "?";
dentry = d_find_alias(inode);
if (dentry) {
spin_lock(&dentry->d_lock);
name = (const char *) dentry->d_name.name;
}
printk(KERN_DEBUG
"%s(%d): dirtied inode %lu (%s) on %s\n",
current->comm, task_pid_nr(current), inode->i_ino,
name, inode->i_sb->s_id);
if (dentry) {
spin_unlock(&dentry->d_lock);
dput(dentry);
}
}
}
/**
* __mark_inode_dirty - internal function
* @inode: inode to mark
* @flags: what kind of dirty (i.e. I_DIRTY_SYNC)
* Mark an inode as dirty. Callers should use mark_inode_dirty or
* mark_inode_dirty_sync.
*
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
* Put the inode on the super block's dirty list.
*
* CAREFUL! We mark it dirty unconditionally, but move it onto the
* dirty list only if it is hashed or if it refers to a blockdev.
* If it was not hashed, it will never be added to the dirty list
* even if it is later hashed, as it will have been marked dirty already.
*
* In short, make sure you hash any inodes _before_ you start marking
* them dirty.
*
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
* This function *must* be atomic for the I_DIRTY_PAGES case -
* set_page_dirty() is called under spinlock in several places.
*
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
* Note that for blockdevs, inode->dirtied_when represents the dirtying time of
* the block-special inode (/dev/hda1) itself. And the ->dirtied_when field of
* the kernel-internal blockdev inode represents the dirtying time of the
* blockdev's pages. This is why for I_DIRTY_PAGES we always use
* page->mapping->host, so the page-dirtying time is recorded in the internal
* blockdev inode.
*/
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
void __mark_inode_dirty(struct inode *inode, int flags)
{
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
struct super_block *sb = inode->i_sb;
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
/*
* Don't do this for I_DIRTY_PAGES - that doesn't actually
* dirty the inode itself
*/
if (flags & (I_DIRTY_SYNC | I_DIRTY_DATASYNC)) {
if (sb->s_op->dirty_inode)
sb->s_op->dirty_inode(inode);
}
/*
* make sure that changes are seen by all cpus before we test i_state
* -- mikulas
*/
smp_mb();
/* avoid the locking if we can */
if ((inode->i_state & flags) == flags)
return;
if (unlikely(block_dump))
block_dump___mark_inode_dirty(inode);
spin_lock(&inode_lock);
if ((inode->i_state & flags) != flags) {
const int was_dirty = inode->i_state & I_DIRTY;
inode->i_state |= flags;
/*
* If the inode is being synced, just update its dirty state.
* The unlocker will place the inode on the appropriate
* superblock list, based upon its state.
*/
if (inode->i_state & I_SYNC)
goto out;
/*
* Only add valid (hashed) inodes to the superblock's
* dirty list. Add blockdev inodes as well.
*/
if (!S_ISBLK(inode->i_mode)) {
if (hlist_unhashed(&inode->i_hash))
goto out;
}
if (inode->i_state & (I_FREEING|I_CLEAR))
goto out;
/*
* If the inode was already on b_dirty/b_io/b_more_io, don't
* reposition it (that would break b_dirty time-ordering).
*/
if (!was_dirty) {
struct bdi_writeback *wb = &inode_to_bdi(inode)->wb;
struct backing_dev_info *bdi = wb->bdi;
if (bdi_cap_writeback_dirty(bdi) &&
!test_bit(BDI_registered, &bdi->state)) {
WARN_ON(1);
printk(KERN_ERR "bdi-%s not registered\n",
bdi->name);
}
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
inode->dirtied_when = jiffies;
list_move(&inode->i_list, &wb->b_dirty);
}
}
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
out:
spin_unlock(&inode_lock);
}
EXPORT_SYMBOL(__mark_inode_dirty);
/*
* Write out a superblock's list of dirty inodes. A wait will be performed
* upon no inodes, all inodes or the final one, depending upon sync_mode.
*
* If older_than_this is non-NULL, then only write out inodes which
* had their first dirtying at a time earlier than *older_than_this.
*
* If `bdi' is non-zero then we're being asked to writeback a specific queue.
* This function assumes that the blockdev superblock's inodes are backed by
* a variety of queues, so all inodes are searched. For other superblocks,
* assume that all inodes are backed by the same queue.
*
* The inodes to be written are parked on bdi->b_io. They are moved back onto
* bdi->b_dirty as they are selected for writing. This way, none can be missed
* on the writer throttling path, and we get decent balancing between many
* throttled threads: we don't want them all piling up on inode_sync_wait.
*/
static void wait_sb_inodes(struct super_block *sb)
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
{
struct inode *inode, *old_inode = NULL;
/*
* We need to be protected against the filesystem going from
* r/o to r/w or vice versa.
*/
WARN_ON(!rwsem_is_locked(&sb->s_umount));
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
spin_lock(&inode_lock);
/*
* Data integrity sync. Must wait for all pages under writeback,
* because there may have been pages dirtied before our sync
* call, but which had writeout started before we write it out.
* In which case, the inode may not be on the dirty list, but
* we still have to wait for that writeout.
*/
list_for_each_entry(inode, &sb->s_inodes, i_sb_list) {
writeback: switch to per-bdi threads for flushing data This gets rid of pdflush for bdi writeout and kupdated style cleaning. pdflush writeout suffers from lack of locality and also requires more threads to handle the same workload, since it has to work in a non-blocking fashion against each queue. This also introduces lumpy behaviour and potential request starvation, since pdflush can be starved for queue access if others are accessing it. A sample ffsb workload that does random writes to files is about 8% faster here on a simple SATA drive during the benchmark phase. File layout also seems a LOT more smooth in vmstat: r b swpd free buff cache si so bi bo in cs us sy id wa 0 1 0 608848 2652 375372 0 0 0 71024 604 24 1 10 48 42 0 1 0 549644 2712 433736 0 0 0 60692 505 27 1 8 48 44 1 0 0 476928 2784 505192 0 0 4 29540 553 24 0 9 53 37 0 1 0 457972 2808 524008 0 0 0 54876 331 16 0 4 38 58 0 1 0 366128 2928 614284 0 0 4 92168 710 58 0 13 53 34 0 1 0 295092 3000 684140 0 0 0 62924 572 23 0 9 53 37 0 1 0 236592 3064 741704 0 0 4 58256 523 17 0 8 48 44 0 1 0 165608 3132 811464 0 0 0 57460 560 21 0 8 54 38 0 1 0 102952 3200 873164 0 0 4 74748 540 29 1 10 48 41 0 1 0 48604 3252 926472 0 0 0 53248 469 29 0 7 47 45 where vanilla tends to fluctuate a lot in the creation phase: r b swpd free buff cache si so bi bo in cs us sy id wa 1 1 0 678716 5792 303380 0 0 0 74064 565 50 1 11 52 36 1 0 0 662488 5864 319396 0 0 4 352 302 329 0 2 47 51 0 1 0 599312 5924 381468 0 0 0 78164 516 55 0 9 51 40 0 1 0 519952 6008 459516 0 0 4 78156 622 56 1 11 52 37 1 1 0 436640 6092 541632 0 0 0 82244 622 54 0 11 48 41 0 1 0 436640 6092 541660 0 0 0 8 152 39 0 0 51 49 0 1 0 332224 6200 644252 0 0 4 102800 728 46 1 13 49 36 1 0 0 274492 6260 701056 0 0 4 12328 459 49 0 7 50 43 0 1 0 211220 6324 763356 0 0 0 106940 515 37 1 10 51 39 1 0 0 160412 6376 813468 0 0 0 8224 415 43 0 6 49 45 1 1 0 85980 6452 886556 0 0 4 113516 575 39 1 11 54 34 0 2 0 85968 6452 886620 0 0 0 1640 158 211 0 0 46 54 A 10 disk test with btrfs performs 26% faster with per-bdi flushing. A SSD based writeback test on XFS performs over 20% better as well, with the throughput being very stable around 1GB/sec, where pdflush only manages 750MB/sec and fluctuates wildly while doing so. Random buffered writes to many files behave a lot better as well, as does random mmap'ed writes. A separate thread is added to sync the super blocks. In the long term, adding sync_supers_bdi() functionality could get rid of this thread again. Signed-off-by: Jens Axboe <jens.axboe@oracle.com>
2009-09-09 03:08:54 -04:00
struct address_space *mapping;
if (inode->i_state & (I_FREEING|I_CLEAR|I_WILL_FREE|I_NEW))
continue;
mapping = inode->i_mapping;
if (mapping->nrpages == 0)
continue;
__iget(inode);
spin_unlock(&inode_lock);
/*
* We hold a reference to 'inode' so it couldn't have
* been removed from s_inodes list while we dropped the
* inode_lock. We cannot iput the inode now as we can
* be holding the last reference and we cannot iput it
* under inode_lock. So we keep the reference and iput
* it later.
*/
iput(old_inode);
old_inode = inode;
filemap_fdatawait(mapping);
cond_resched();
spin_lock(&inode_lock);
}
spin_unlock(&inode_lock);
iput(old_inode);
}
/**
* writeback_inodes_sb - writeback dirty inodes from given super_block
* @sb: the superblock
*
* Start writeback on some inodes on this super_block. No guarantees are made
* on how many (if any) will be written, and this function does not wait
* for IO completion of submitted IO. The number of pages submitted is
* returned.
*/
void writeback_inodes_sb(struct super_block *sb)
{
unsigned long nr_dirty = global_page_state(NR_FILE_DIRTY);
unsigned long nr_unstable = global_page_state(NR_UNSTABLE_NFS);
long nr_to_write;
nr_to_write = nr_dirty + nr_unstable +
(inodes_stat.nr_inodes - inodes_stat.nr_unused);
bdi_start_writeback(sb->s_bdi, sb, nr_to_write);
}
EXPORT_SYMBOL(writeback_inodes_sb);
/**
* writeback_inodes_sb_if_idle - start writeback if none underway
* @sb: the superblock
*
* Invoke writeback_inodes_sb if no writeback is currently underway.
* Returns 1 if writeback was started, 0 if not.
*/
int writeback_inodes_sb_if_idle(struct super_block *sb)
{
if (!writeback_in_progress(sb->s_bdi)) {
writeback_inodes_sb(sb);
return 1;
} else
return 0;
}
EXPORT_SYMBOL(writeback_inodes_sb_if_idle);
/**
* sync_inodes_sb - sync sb inode pages
* @sb: the superblock
*
* This function writes and waits on any dirty inode belonging to this
* super_block. The number of pages synced is returned.
*/
void sync_inodes_sb(struct super_block *sb)
{
bdi_sync_writeback(sb->s_bdi, sb);
wait_sb_inodes(sb);
}
EXPORT_SYMBOL(sync_inodes_sb);
/**
[PATCH] fix nr_unused accounting, and avoid recursing in iput with I_WILL_FREE set list_move(&inode->i_list, &inode_in_use); } else { list_move(&inode->i_list, &inode_unused); + inodes_stat.nr_unused++; } } wake_up_inode(inode); Are you sure the above diff is correct? It was added somewhere between 2.6.5 and 2.6.8. I think it's wrong. The only way I can imagine the i_count to be zero in the above path, is that I_WILL_FREE is set. And if I_WILL_FREE is set, then we must not increase nr_unused. So I believe the above change is buggy and it will definitely overstate the number of unused inodes and it should be backed out. Note that __writeback_single_inode before calling __sync_single_inode, can drop the spinlock and we can have both the dirty and locked bitflags clear here: spin_unlock(&inode_lock); __wait_on_inode(inode); iput(inode); XXXXXXX spin_lock(&inode_lock); } use inode again here a construct like the above makes zero sense from a reference counting standpoint. Either we don't ever use the inode again after the iput, or the inode_lock should be taken _before_ executing the iput (i.e. a __iput would be required). Taking the inode_lock after iput means the iget was useless if we keep using the inode after the iput. So the only chance the 2.6 was safe to call __writeback_single_inode with the i_count == 0, is that I_WILL_FREE is set (I_WILL_FREE will prevent the VM to free the inode in XXXXX). Potentially calling the above iput with I_WILL_FREE was also wrong because it would recurse in iput_final (the second mainline bug). The below (untested) patch fixes the nr_unused accounting, avoids recursing in iput when I_WILL_FREE is set and makes sure (with the BUG_ON) that we don't corrupt memory and that all holders that don't set I_WILL_FREE, keeps a reference on the inode! Signed-off-by: Andrea Arcangeli <andrea@suse.de> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2005-10-30 18:03:05 -05:00
* write_inode_now - write an inode to disk
* @inode: inode to write to disk
* @sync: whether the write should be synchronous or not
*
* This function commits an inode to disk immediately if it is dirty. This is
* primarily needed by knfsd.
*
[PATCH] fix nr_unused accounting, and avoid recursing in iput with I_WILL_FREE set list_move(&inode->i_list, &inode_in_use); } else { list_move(&inode->i_list, &inode_unused); + inodes_stat.nr_unused++; } } wake_up_inode(inode); Are you sure the above diff is correct? It was added somewhere between 2.6.5 and 2.6.8. I think it's wrong. The only way I can imagine the i_count to be zero in the above path, is that I_WILL_FREE is set. And if I_WILL_FREE is set, then we must not increase nr_unused. So I believe the above change is buggy and it will definitely overstate the number of unused inodes and it should be backed out. Note that __writeback_single_inode before calling __sync_single_inode, can drop the spinlock and we can have both the dirty and locked bitflags clear here: spin_unlock(&inode_lock); __wait_on_inode(inode); iput(inode); XXXXXXX spin_lock(&inode_lock); } use inode again here a construct like the above makes zero sense from a reference counting standpoint. Either we don't ever use the inode again after the iput, or the inode_lock should be taken _before_ executing the iput (i.e. a __iput would be required). Taking the inode_lock after iput means the iget was useless if we keep using the inode after the iput. So the only chance the 2.6 was safe to call __writeback_single_inode with the i_count == 0, is that I_WILL_FREE is set (I_WILL_FREE will prevent the VM to free the inode in XXXXX). Potentially calling the above iput with I_WILL_FREE was also wrong because it would recurse in iput_final (the second mainline bug). The below (untested) patch fixes the nr_unused accounting, avoids recursing in iput when I_WILL_FREE is set and makes sure (with the BUG_ON) that we don't corrupt memory and that all holders that don't set I_WILL_FREE, keeps a reference on the inode! Signed-off-by: Andrea Arcangeli <andrea@suse.de> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2005-10-30 18:03:05 -05:00
* The caller must either have a ref on the inode or must have set I_WILL_FREE.
*/
int write_inode_now(struct inode *inode, int sync)
{
int ret;
struct writeback_control wbc = {
.nr_to_write = LONG_MAX,
.sync_mode = sync ? WB_SYNC_ALL : WB_SYNC_NONE,
[PATCH] writeback: fix range handling When a writeback_control's `start' and `end' fields are used to indicate a one-byte-range starting at file offset zero, the required values of .start=0,.end=0 mean that the ->writepages() implementation has no way of telling that it is being asked to perform a range request. Because we're currently overloading (start == 0 && end == 0) to mean "this is not a write-a-range request". To make all this sane, the patch changes range of writeback_control. So caller does: If it is calling ->writepages() to write pages, it sets range (range_start/end or range_cyclic) always. And if range_cyclic is true, ->writepages() thinks the range is cyclic, otherwise it just uses range_start and range_end. This patch does, - Add LLONG_MAX, LLONG_MIN, ULLONG_MAX to include/linux/kernel.h -1 is usually ok for range_end (type is long long). But, if someone did, range_end += val; range_end is "val - 1" u64val = range_end >> bits; u64val is "~(0ULL)" or something, they are wrong. So, this adds LLONG_MAX to avoid nasty things, and uses LLONG_MAX for range_end. - All callers of ->writepages() sets range_start/end or range_cyclic. - Fix updates of ->writeback_index. It seems already bit strange. If it starts at 0 and ended by check of nr_to_write, this last index may reduce chance to scan end of file. So, this updates ->writeback_index only if range_cyclic is true or whole-file is scanned. Signed-off-by: OGAWA Hirofumi <hirofumi@mail.parknet.co.jp> Cc: Nathan Scott <nathans@sgi.com> Cc: Anton Altaparmakov <aia21@cantab.net> Cc: Steven French <sfrench@us.ibm.com> Cc: "Vladimir V. Saveliev" <vs@namesys.com> Signed-off-by: Andrew Morton <akpm@osdl.org> Signed-off-by: Linus Torvalds <torvalds@osdl.org>
2006-06-23 05:03:26 -04:00
.range_start = 0,
.range_end = LLONG_MAX,
};
if (!mapping_cap_writeback_dirty(inode->i_mapping))
wbc.nr_to_write = 0;
might_sleep();
spin_lock(&inode_lock);
ret = writeback_single_inode(inode, &wbc);
spin_unlock(&inode_lock);
if (sync)
inode_sync_wait(inode);
return ret;
}
EXPORT_SYMBOL(write_inode_now);
/**
* sync_inode - write an inode and its pages to disk.
* @inode: the inode to sync
* @wbc: controls the writeback mode
*
* sync_inode() will write an inode and its pages to disk. It will also
* correctly update the inode on its superblock's dirty inode lists and will
* update inode->i_state.
*
* The caller must have a ref on the inode.
*/
int sync_inode(struct inode *inode, struct writeback_control *wbc)
{
int ret;
spin_lock(&inode_lock);
ret = writeback_single_inode(inode, wbc);
spin_unlock(&inode_lock);
return ret;
}
EXPORT_SYMBOL(sync_inode);