Revert "mmc: sdhci-xenon: fix annoying 1.8V regulator warning"
commit 7e2646ed47542123168d43916b84b954532e5386 upstream.
This reverts commit bb32e1987bc55ce1db400faf47d85891da3c9b9f.
Commit 1a3ed0dc3594 ("mmc: sdhci-xenon: fix 1.8v regulator stabilization")
contains proper fix for the issue described in commit bb32e1987bc5 ("mmc:
sdhci-xenon: fix annoying 1.8V regulator warning").
Fixes: 8d876bf472
("mmc: sdhci-xenon: wait 5ms after set 1.8V signal enable")
Cc: stable@vger.kernel.org # 1a3ed0dc3594 ("mmc: sdhci-xenon: fix 1.8v regulator stabilization")
Signed-off-by: Pali Rohár <pali@kernel.org>
Reviewed-by: Marek Behún <kabel@kernel.org>
Reviewed-by: Marcin Wojtas <mw@semihalf.com>
Link: https://lore.kernel.org/r/20220318141441.32329-1-pali@kernel.org
Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
c79c1846bd
commit
0869cb9f62
@ -240,16 +240,6 @@ static void xenon_voltage_switch(struct sdhci_host *host)
|
||||
{
|
||||
/* Wait for 5ms after set 1.8V signal enable bit */
|
||||
usleep_range(5000, 5500);
|
||||
|
||||
/*
|
||||
* For some reason the controller's Host Control2 register reports
|
||||
* the bit representing 1.8V signaling as 0 when read after it was
|
||||
* written as 1. Subsequent read reports 1.
|
||||
*
|
||||
* Since this may cause some issues, do an empty read of the Host
|
||||
* Control2 register here to circumvent this.
|
||||
*/
|
||||
sdhci_readw(host, SDHCI_HOST_CONTROL2);
|
||||
}
|
||||
|
||||
static const struct sdhci_ops sdhci_xenon_ops = {
|
||||
|