mac80211: Fix monitor MTU limit so that A-MSDUs get through
[ Upstream commit 79f5962baea74ce1cd4e5949598944bff854b166 ] The maximum MTU was set to 2304, which is the maximum MSDU size. While this is valid for normal WLAN interfaces, it is too low for monitor interfaces. A monitor interface may receive and inject MPDU frames, and the maximum MPDU frame size is larger than 2304. The MPDU may also contain an A-MSDU frame, in which case the size may be much larger than the MTU limit. Since the maximum size of an A-MSDU depends on the PHY mode of the transmitting STA, it is not possible to set an exact MTU limit for a monitor interface. Now the maximum MTU for a monitor interface is unrestricted. Signed-off-by: Johan Almbladh <johan.almbladh@anyfinetworks.com> Link: https://lore.kernel.org/r/20210628123246.2070558-1-johan.almbladh@anyfinetworks.com Signed-off-by: Johannes Berg <johannes.berg@intel.com> Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:
parent
1e2842fb7e
commit
a66049c5ff
@ -1875,8 +1875,15 @@ int ieee80211_if_add(struct ieee80211_local *local, const char *name,
|
||||
|
||||
netdev_set_default_ethtool_ops(ndev, &ieee80211_ethtool_ops);
|
||||
|
||||
/* MTU range: 256 - 2304 */
|
||||
/* MTU range is normally 256 - 2304, where the upper limit is
|
||||
* the maximum MSDU size. Monitor interfaces send and receive
|
||||
* MPDU and A-MSDU frames which may be much larger so we do
|
||||
* not impose an upper limit in that case.
|
||||
*/
|
||||
ndev->min_mtu = 256;
|
||||
if (type == NL80211_IFTYPE_MONITOR)
|
||||
ndev->max_mtu = 0;
|
||||
else
|
||||
ndev->max_mtu = local->hw.max_mtu;
|
||||
|
||||
ret = register_netdevice(ndev);
|
||||
|