Commit Graph

21 Commits

Author SHA1 Message Date
Adrian Bunk
5110bd21b8 sparc: remove CONFIG_SUN4
While doing some easy cleanups on the sparc code I noticed that the
CONFIG_SUN4 code seems to be worse than the rest - there were some
"I don't know how it should work, but the current code definitely cannot
work." places.

And while I have seen people running Linux on machines like a
SPARCstation 5 a few years ago I don't recall having seen sun4
machines, even less ones running Linux.

Signed-off-by: Adrian Bunk <bunk@kernel.org>
Signed-off-by: David S. Miller <davem@davemloft.net>
2008-08-31 20:59:37 -07:00
David S. Miller
2481d76615 sparc: Add mutex for set property calls.
On some platforms, the I2C controller is shared between the OS and
OBP.  OBP uses this I2C controller to access the EEPROM, and thus is
programmed when the kernel calls prom_setprop().

Wrap such calls with the new of_set_property_mutex.

Relevant I2C bus drivers can grab this mutex around top-level I2C
operations to provide the proper protection.

Signed-off-by: David S. Miller <davem@davemloft.net>
2008-08-24 20:33:55 -07:00
David S. Miller
46bcea7751 [SPARC]: Centralize find_in_proplist() instead of duplicating N times.
Signed-off-by: David S. Miller <davem@davemloft.net>
2007-08-07 18:46:36 -07:00
David S. Miller
f623f388e4 [SPARC]: Fix serial console node string creation.
The string setting code depends upon the original value of the
"skip" variable, not the one that gets modified by the node
traversal loop.

Based upon a patch by Mark Fortescue.

Signed-off-by: David S. Miller <davem@davemloft.net>
2007-07-30 00:27:37 -07:00
David S. Miller
c73fcc846c [SPARC]: Fix serial console device detection.
The current scheme works on static interpretation of text names, which
is wrong.

The output-device setting, for example, must be resolved via an alias
or similar to a full path name to the console device.

Paths also contain an optional set of 'options', which starts with a
colon at the end of the path.  The option area is used to specify
which of two serial ports ('a' or 'b') the path refers to when a
device node drives multiple ports.  'a' is assumed if the option
specification is missing.

This was caught by the UltraSPARC-T1 simulator.  The 'output-device'
property was set to 'ttya' and we didn't pick upon the fact that this
is an OBP alias set to '/virtual-devices/console'.  Instead we saw it
as the first serial console device, instead of the hypervisor console.

The infrastructure is now there to take advantage of this to resolve
the console correctly even in multi-head situations in fbcon too.

Thanks to Greg Onufer for the bug report.

Signed-off-by: David S. Miller <davem@davemloft.net>
2007-07-20 16:59:26 -07:00
Stephen Rothwell
1ef4d4242d Consolidate of_find_node_by routines
This consolidates the routines of_find_node_by_path, of_find_node_by_name,
of_find_node_by_type and of_find_compatible_device.  Again, the comparison
of strings are done differently by Sparc and PowerPC and also these add
read_locks around the iterations.

Signed-off-by: Stephen Rothwell <sfr@canb.auug.org.au>
Acked-by: Paul Mackerras <paulus@samba.org>
Acked-by: David S. Miller <davem@davemloft.net>
2007-07-20 13:39:06 +10:00
Stephen Rothwell
d1cd355a5e Consolidate of_get_next_child
This adds a read_lock around the child/next accesses on Sparc.

Signed-off-by: Stephen Rothwell <sfr@canb.auug.org.au>
Acked-by: Paul Mackerras <paulus@samba.org>
Acked-by: David S. Miller <davem@davemloft.net>
2007-07-20 13:34:26 +10:00
Stephen Rothwell
e679c5f445 Consolidate of_get_parent
This requires creating dummy of_node_{get,put} routines for sparc and
sparc64.  It also adds a read_lock around the parent accesses.

Signed-off-by: Stephen Rothwell <sfr@canb.auug.org.au>
Acked-by: Paul Mackerras <paulus@samba.org>
Acked-by: David S. Miller <davem@davemloft.net>
2007-07-20 13:32:58 +10:00
Stephen Rothwell
581b605a83 Consolidate of_find_property
The only change here is that a readlock is taken while the property list
is being traversed on Sparc where it was not taken previously.

Also, Sparc uses strcasecmp to compare property names while PowerPC
uses strcmp.

Signed-off-by: Stephen Rothwell <sfr@canb.auug.org.au>
Acked-by: Paul Mackerras <paulus@samba.org>
Acked-by: David S. Miller <davem@davemloft.net>
2007-07-20 13:32:24 +10:00
Stephen Rothwell
0081cbc373 Consolidate of_device_is_compatible
The only difference here is that Sparc uses strncmp to match compatibility
names while PowerPC uses strncasecmp.

Signed-off-by: Stephen Rothwell <sfr@canb.auug.org.au>
Acked-by: Paul Mackerras <paulus@samba.org>
Acked-by: David S. Miller <davem@davemloft.net>
2007-07-20 13:29:51 +10:00
Stephen Rothwell
97e873e5c8 Start split out of common open firmware code
This creates drivers/of/base.c (depending on CONFIG_OF) and puts
the first trivially common bits from the prom.c files into it.

Signed-off-by: Stephen Rothwell <sfr@canb.auug.org.au>
Acked-by: Paul Mackerras <paulus@samba.org>
Acked-by: David S. Miller <davem@davemloft.net>
2007-07-20 13:28:41 +10:00
David S. Miller
a8b8814bdf [SPARC]: Use strcasecmp for OFW property name comparisons.
This allows us to simplify sharing code with powerpc which
has properties that have various forms of capitalization
when on the sparc64 side the property is all lower-case.

Signed-off-by: David S. Miller <davem@davemloft.net>
2007-04-26 01:54:41 -07:00
Stephen Rothwell
357418e7ca [SPARC]: constify some paramaters of OF routines
This starts bringing the PowerPC and Sparc implemetations back closer
together.

Signed-off-by: Stephen Rothwell <sfr@canb.auug.org.au>
Signed-off-by: David S. Miller <davem@davemloft.net>
2007-04-26 01:54:37 -07:00
Stephen Rothwell
64b94701c0 [SPARC/64]: constify of_get_property return
Finally, we actually change the functions themselves.

Signed-off-by: Stephen Rothwell <sfr@canb.auug.org.au>
Signed-off-by: David S. Miller <davem@davemloft.net>
2007-04-26 01:54:35 -07:00
Stephen Rothwell
8271f04242 [SPARC]: constify of_get_property return: arch/sparc
Signed-off-by: Stephen Rothwell <sfr@canb.auug.org.au>
Signed-off-by: David S. Miller <davem@davemloft.net>
2007-04-26 01:54:22 -07:00
Martin Habets
078830eaa8 [SPARC32]: Fix prom.c build warning
Fix these 2.6.19-rc1 build warnings:

  CC      arch/sparc/kernel/prom.o
arch/sparc/kernel/prom.c: In function `of_set_property':
arch/sparc/kernel/prom.c:246: warning: passing arg 2 of `prom_setprop' discards qualifiers from pointer target type
arch/sparc/kernel/prom.c: In function `build_one_prop':
arch/sparc/kernel/prom.c:446: warning: unused variable `len'
arch/sparc/kernel/prom.c:480: warning: ignoring return value of `prom_getproperty', declared with attribute warn_unused_result

Signed-off-by: Martin Habets <errandir_news@mph.eclipse.co.uk>
Signed-off-by: David S. Miller <davem@davemloft.net>
2006-10-09 18:10:16 -07:00
Bob Breuer
f7785a64d1 [SPARC]: Fix property name acquisition in prom.c
On sparc32 the prom_{first,next}prop() interfaces work
a little differently.  The buffer argument is ignored on
sparc32 and the firmware just returns a raw pointer to
the property name.

Signed-off-by: David S. Miller <davem@davemloft.net>
2006-07-21 14:18:04 -07:00
David S. Miller
3ae9a3489a [SPARC]: Add of_n_{addr,size}_cells().
Signed-off-by: David S. Miller <davem@davemloft.net>
2006-06-29 16:37:10 -07:00
David S. Miller
87b385da1f [SPARC]: Add unique device_node IDs and a ".node" property.
Signed-off-by: David S. Miller <davem@davemloft.net>
2006-06-25 23:18:57 -07:00
David S. Miller
fb7cd9d9ac [SPARC]: Add of_set_property() interface.
Signed-off-by: David S. Miller <davem@davemloft.net>
2006-06-25 23:18:36 -07:00
David S. Miller
942a6bdd1c [SPARC]: Port sparc64 in-kernel device tree code to sparc32.
Signed-off-by: David S. Miller <davem@davemloft.net>
2006-06-23 23:15:45 -07:00