Commit Graph

9 Commits

Author SHA1 Message Date
Oliver Hartkopp
c7cd606f60 can: Fix data length code handling in rx path
A valid CAN dataframe can have a data length code (DLC) of 0 .. 8 data bytes.

When reading the CAN controllers register the 4-bit value may contain values
from 0 .. 15 which may exceed the reserved space in the socket buffer!

The ISO 11898-1 Chapter 8.4.2.3 (DLC field) says that register values > 8
should be reduced to 8 without any error reporting or frame drop.

This patch introduces a new helper macro to cast a given 4-bit data length
code (dlc) to __u8 and ensure the DLC value to be max. 8 bytes.

The different handlings in the rx path of the CAN netdevice drivers are fixed.

Signed-off-by: Oliver Hartkopp <oliver@hartkopp.net>
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2009-12-13 19:47:42 -08:00
Joe Perches
8e95a2026f drivers/net: Move && and || to end of previous line
Only files where David Miller is the primary git-signer.
wireless, wimax, ixgbe, etc are not modified.

Compile tested x86 allyesconfig only
Not all files compiled (not x86 compatible)

Added a few > 80 column lines, which I ignored.
Existing checkpatch complaints ignored.

Signed-off-by: Joe Perches <joe@perches.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2009-12-03 13:18:01 -08:00
David S. Miller
a2bfbc072e Merge branch 'master' of master.kernel.org:/pub/scm/linux/kernel/git/davem/net-2.6
Conflicts:
	drivers/net/can/Kconfig
2009-11-17 00:05:02 -08:00
Oliver Hartkopp
b93cf3f0bb can: Fix driver Kconfig structure
In 2.6.32-rc the new EMS USB CAN driver was contributed and added the Kconfig
entry right behind an entry of the same *vendor*. This teared the SJA1000
based driver selection into pieces.

This fix cleans up the 2.6.32-rc Kconfig files for the CAN drivers and moves
the SJA1000 and USB Kconfig portions into the belonging directories.

As there are many new CAN drivers in the queue getting this cleanup into
2.6.32-rc would massively reduce the problems for the upcoming drivers.

Thanks,
Oliver

Signed-off-by: Oliver Hartkopp <oliver@hartkopp.net>
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-13 19:56:55 -08:00
David S. Miller
d0e1e88d6e Merge branch 'master' of master.kernel.org:/pub/scm/linux/kernel/git/davem/net-2.6
Conflicts:
	drivers/net/can/usb/ems_usb.c
2009-11-08 23:00:54 -08:00
Sebastian Haas
2b2072e902 ems_usb: Fix byte order issues on big endian machines
CPC-USB is using a ARM7 core with little endian byte order. The "id" field
in can_msg needs byte order conversion from/to CPU byte order.

Signed-off-by: Sebastian Haas <haas@ems-wuensche.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2009-11-06 20:26:07 -08:00
Wolfgang Grandegger
7b6856a029 can: provide library functions for skb allocation
This patch makes the private functions alloc_can_skb() and
alloc_can_err_skb() of the at91_can driver public and adapts all
drivers to use these. While making the patch I realized, that
the skb's are *not* setup consistently. It's now done as shown
below:

  skb->protocol = htons(ETH_P_CAN);
  skb->pkt_type = PACKET_BROADCAST;
  skb->ip_summed = CHECKSUM_UNNECESSARY;
  *cf = (struct can_frame *)skb_put(skb, sizeof(struct can_frame));
  memset(*cf, 0, sizeof(struct can_frame));

The frame is zeroed out to avoid uninitialized data to be passed to
user space. Some drivers or library code did not set "pkt_type" or
"ip_summed". Also,  "__constant_htons()" should not be used for
runtime invocations, as pointed out by David Miller.

Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2009-10-20 00:08:01 -07:00
Wolfgang Grandegger
a6e4bc5304 can: make the number of echo skb's configurable
This patch allows the CAN controller driver to define the number of echo
skb's used for the local loopback (echo), as suggested by Kurt Van
Dijck, with the function:

  struct net_device *alloc_candev(int sizeof_priv,
                                  unsigned int echo_skb_max);

The CAN drivers have been adapted accordingly. For the ems_usb driver,
as suggested by Sebastian Haas, the number of echo skb's has been
increased to 10, which improves the transmission performance a lot.

Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: Kurt Van Dijck <kurt.van.dijck@eia.be>
Signed-off-by: David S. Miller <davem@davemloft.net>
2009-10-13 03:44:04 -07:00
Sebastian Haas
702171adee ems_usb: Added support for EMS CPC-USB/ARM7 CAN/USB interface
This patch adds support for one channel CAN/USB interace CPC-USB/ARM7 from
EMS Dr. Thomas Wuensche (http://www.ems-wuensche.com).

Signed-off-by: Sebastian Haas <haas@ems-wuensche.com>
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
2009-09-21 11:32:26 -07:00