The idle check loop has a greater-than where it should have a less-than.
This causes the ds2482 driver to check for the idle condition exactly
once, which causes it to fail on faster machines.
Signed-off-by: Ben Gardner <gardner.ben@gmail.com>
Signed-off-by: Evgeniy Polyakov <johnpol@2ka.mipt.ru>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
Use mutexes instead of semaphores.
Patch tested on x86_64 and i386 with test bus master driver.
Signed-off-by: Evgeniy Polyakov <johnpol@2ka.mipt.ru>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
W1_DS9490 was renamed to W1_MASTER_DS9490, but the entry in the
dependencies of W1_MASTER_DS9490_BRIDGE was forgotten.
Signed-off-by: Adrian Bunk <bunk@stusta.de>