android_kernel_xiaomi_sm8350/drivers/power/olpc_battery.c
Andres Salomon 3ef0e1f8ca x86: olpc: add One Laptop Per Child architecture support
This adds support for OLPC XO hardware.  Open Firmware on XOs don't contain
the VSA, so it is necessary to emulate the PCI BARs in the kernel.  This also
adds functionality for running EC commands, and a CONFIG_OLPC.

A number of OLPC drivers depend upon CONFIG_OLPC.

olpc_ec_timeout is a hack to work around Embedded Controller bugs.

[akpm@linux-foundation.org: build fix]
[akpm@linux-foundation.org: geode_has_vsa build fix]
[akpm@linux-foundation.org: olpc_register_battery_callback doesn't exist]
Signed-off-by: Andres Salomon <dilinger@debian.org>
Acked-by: Ingo Molnar <mingo@elte.hu>
Cc: Thomas Gleixner <tglx@linutronix.de>
Cc: Andi Kleen <ak@suse.de>
Cc: Jordan Crouse <jordan.crouse@amd.com>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
2008-04-29 08:06:07 -07:00

341 lines
8.8 KiB
C

/*
* Battery driver for One Laptop Per Child board.
*
* Copyright © 2006 David Woodhouse <dwmw2@infradead.org>
*
* This program is free software; you can redistribute it and/or modify
* it under the terms of the GNU General Public License version 2 as
* published by the Free Software Foundation.
*/
#include <linux/module.h>
#include <linux/err.h>
#include <linux/platform_device.h>
#include <linux/power_supply.h>
#include <linux/jiffies.h>
#include <linux/sched.h>
#include <asm/olpc.h>
#define EC_BAT_VOLTAGE 0x10 /* uint16_t, *9.76/32, mV */
#define EC_BAT_CURRENT 0x11 /* int16_t, *15.625/120, mA */
#define EC_BAT_ACR 0x12
#define EC_BAT_TEMP 0x13 /* uint16_t, *100/256, °C */
#define EC_AMB_TEMP 0x14 /* uint16_t, *100/256, °C */
#define EC_BAT_STATUS 0x15 /* uint8_t, bitmask */
#define EC_BAT_SOC 0x16 /* uint8_t, percentage */
#define EC_BAT_SERIAL 0x17 /* uint8_t[6] */
#define EC_BAT_EEPROM 0x18 /* uint8_t adr as input, uint8_t output */
#define EC_BAT_ERRCODE 0x1f /* uint8_t, bitmask */
#define BAT_STAT_PRESENT 0x01
#define BAT_STAT_FULL 0x02
#define BAT_STAT_LOW 0x04
#define BAT_STAT_DESTROY 0x08
#define BAT_STAT_AC 0x10
#define BAT_STAT_CHARGING 0x20
#define BAT_STAT_DISCHARGING 0x40
#define BAT_ERR_INFOFAIL 0x02
#define BAT_ERR_OVERVOLTAGE 0x04
#define BAT_ERR_OVERTEMP 0x05
#define BAT_ERR_GAUGESTOP 0x06
#define BAT_ERR_OUT_OF_CONTROL 0x07
#define BAT_ERR_ID_FAIL 0x09
#define BAT_ERR_ACR_FAIL 0x10
#define BAT_ADDR_MFR_TYPE 0x5F
/*********************************************************************
* Power
*********************************************************************/
static int olpc_ac_get_prop(struct power_supply *psy,
enum power_supply_property psp,
union power_supply_propval *val)
{
int ret = 0;
uint8_t status;
switch (psp) {
case POWER_SUPPLY_PROP_ONLINE:
ret = olpc_ec_cmd(EC_BAT_STATUS, NULL, 0, &status, 1);
if (ret)
return ret;
val->intval = !!(status & BAT_STAT_AC);
break;
default:
ret = -EINVAL;
break;
}
return ret;
}
static enum power_supply_property olpc_ac_props[] = {
POWER_SUPPLY_PROP_ONLINE,
};
static struct power_supply olpc_ac = {
.name = "olpc-ac",
.type = POWER_SUPPLY_TYPE_MAINS,
.properties = olpc_ac_props,
.num_properties = ARRAY_SIZE(olpc_ac_props),
.get_property = olpc_ac_get_prop,
};
/*********************************************************************
* Battery properties
*********************************************************************/
static int olpc_bat_get_property(struct power_supply *psy,
enum power_supply_property psp,
union power_supply_propval *val)
{
int ret = 0;
int16_t ec_word;
uint8_t ec_byte;
ret = olpc_ec_cmd(EC_BAT_STATUS, NULL, 0, &ec_byte, 1);
if (ret)
return ret;
/* Theoretically there's a race here -- the battery could be
removed immediately after we check whether it's present, and
then we query for some other property of the now-absent battery.
It doesn't matter though -- the EC will return the last-known
information, and it's as if we just ran that _little_ bit faster
and managed to read it out before the battery went away. */
if (!(ec_byte & BAT_STAT_PRESENT) && psp != POWER_SUPPLY_PROP_PRESENT)
return -ENODEV;
switch (psp) {
case POWER_SUPPLY_PROP_STATUS:
if (olpc_platform_info.ecver > 0x44) {
if (ec_byte & BAT_STAT_CHARGING)
val->intval = POWER_SUPPLY_STATUS_CHARGING;
else if (ec_byte & BAT_STAT_DISCHARGING)
val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
else if (ec_byte & BAT_STAT_FULL)
val->intval = POWER_SUPPLY_STATUS_FULL;
else /* er,... */
val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
} else {
/* Older EC didn't report charge/discharge bits */
if (!(ec_byte & BAT_STAT_AC)) /* No AC means discharging */
val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
else if (ec_byte & BAT_STAT_FULL)
val->intval = POWER_SUPPLY_STATUS_FULL;
else /* Not _necessarily_ true but EC doesn't tell all yet */
val->intval = POWER_SUPPLY_STATUS_CHARGING;
break;
}
case POWER_SUPPLY_PROP_PRESENT:
val->intval = !!(ec_byte & BAT_STAT_PRESENT);
break;
case POWER_SUPPLY_PROP_HEALTH:
if (ec_byte & BAT_STAT_DESTROY)
val->intval = POWER_SUPPLY_HEALTH_DEAD;
else {
ret = olpc_ec_cmd(EC_BAT_ERRCODE, NULL, 0, &ec_byte, 1);
if (ret)
return ret;
switch (ec_byte) {
case 0:
val->intval = POWER_SUPPLY_HEALTH_GOOD;
break;
case BAT_ERR_OVERTEMP:
val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
break;
case BAT_ERR_OVERVOLTAGE:
val->intval = POWER_SUPPLY_HEALTH_OVERVOLTAGE;
break;
case BAT_ERR_INFOFAIL:
case BAT_ERR_OUT_OF_CONTROL:
case BAT_ERR_ID_FAIL:
case BAT_ERR_ACR_FAIL:
val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE;
break;
default:
/* Eep. We don't know this failure code */
return -EIO;
}
}
break;
case POWER_SUPPLY_PROP_MANUFACTURER:
ec_byte = BAT_ADDR_MFR_TYPE;
ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
if (ret)
return ret;
switch (ec_byte >> 4) {
case 1:
val->strval = "Gold Peak";
break;
case 2:
val->strval = "BYD";
break;
default:
val->strval = "Unknown";
break;
}
break;
case POWER_SUPPLY_PROP_TECHNOLOGY:
ec_byte = BAT_ADDR_MFR_TYPE;
ret = olpc_ec_cmd(EC_BAT_EEPROM, &ec_byte, 1, &ec_byte, 1);
if (ret)
return ret;
switch (ec_byte & 0xf) {
case 1:
val->intval = POWER_SUPPLY_TECHNOLOGY_NiMH;
break;
case 2:
val->intval = POWER_SUPPLY_TECHNOLOGY_LiFe;
break;
default:
val->intval = POWER_SUPPLY_TECHNOLOGY_UNKNOWN;
break;
}
break;
case POWER_SUPPLY_PROP_VOLTAGE_AVG:
ret = olpc_ec_cmd(EC_BAT_VOLTAGE, NULL, 0, (void *)&ec_word, 2);
if (ret)
return ret;
ec_word = be16_to_cpu(ec_word);
val->intval = ec_word * 9760L / 32;
break;
case POWER_SUPPLY_PROP_CURRENT_AVG:
ret = olpc_ec_cmd(EC_BAT_CURRENT, NULL, 0, (void *)&ec_word, 2);
if (ret)
return ret;
ec_word = be16_to_cpu(ec_word);
val->intval = ec_word * 15625L / 120;
break;
case POWER_SUPPLY_PROP_CAPACITY:
ret = olpc_ec_cmd(EC_BAT_SOC, NULL, 0, &ec_byte, 1);
if (ret)
return ret;
val->intval = ec_byte;
break;
case POWER_SUPPLY_PROP_TEMP:
ret = olpc_ec_cmd(EC_BAT_TEMP, NULL, 0, (void *)&ec_word, 2);
if (ret)
return ret;
ec_word = be16_to_cpu(ec_word);
val->intval = ec_word * 100 / 256;
break;
case POWER_SUPPLY_PROP_TEMP_AMBIENT:
ret = olpc_ec_cmd(EC_AMB_TEMP, NULL, 0, (void *)&ec_word, 2);
if (ret)
return ret;
ec_word = be16_to_cpu(ec_word);
val->intval = ec_word * 100 / 256;
break;
default:
ret = -EINVAL;
break;
}
return ret;
}
static enum power_supply_property olpc_bat_props[] = {
POWER_SUPPLY_PROP_STATUS,
POWER_SUPPLY_PROP_PRESENT,
POWER_SUPPLY_PROP_HEALTH,
POWER_SUPPLY_PROP_TECHNOLOGY,
POWER_SUPPLY_PROP_VOLTAGE_AVG,
POWER_SUPPLY_PROP_CURRENT_AVG,
POWER_SUPPLY_PROP_CAPACITY,
POWER_SUPPLY_PROP_TEMP,
POWER_SUPPLY_PROP_TEMP_AMBIENT,
POWER_SUPPLY_PROP_MANUFACTURER,
};
/*********************************************************************
* Initialisation
*********************************************************************/
static struct platform_device *bat_pdev;
static struct power_supply olpc_bat = {
.properties = olpc_bat_props,
.num_properties = ARRAY_SIZE(olpc_bat_props),
.get_property = olpc_bat_get_property,
.use_for_apm = 1,
};
void olpc_battery_trigger_uevent(unsigned long cause)
{
if (cause & EC_SCI_SRC_ACPWR)
kobject_uevent(&olpc_ac.dev->kobj, KOBJ_CHANGE);
if (cause & (EC_SCI_SRC_BATERR|EC_SCI_SRC_BATSOC|EC_SCI_SRC_BATTERY))
kobject_uevent(&olpc_bat.dev->kobj, KOBJ_CHANGE);
}
static int __init olpc_bat_init(void)
{
int ret = 0;
uint8_t status;
if (!olpc_platform_info.ecver)
return -ENXIO;
if (olpc_platform_info.ecver < 0x43) {
printk(KERN_NOTICE "OLPC EC version 0x%02x too old for battery driver.\n", olpc_platform_info.ecver);
return -ENXIO;
}
ret = olpc_ec_cmd(EC_BAT_STATUS, NULL, 0, &status, 1);
if (ret)
return ret;
/* Ignore the status. It doesn't actually matter */
bat_pdev = platform_device_register_simple("olpc-battery", 0, NULL, 0);
if (IS_ERR(bat_pdev))
return PTR_ERR(bat_pdev);
ret = power_supply_register(&bat_pdev->dev, &olpc_ac);
if (ret)
goto ac_failed;
olpc_bat.name = bat_pdev->name;
ret = power_supply_register(&bat_pdev->dev, &olpc_bat);
if (ret)
goto battery_failed;
goto success;
battery_failed:
power_supply_unregister(&olpc_ac);
ac_failed:
platform_device_unregister(bat_pdev);
success:
return ret;
}
static void __exit olpc_bat_exit(void)
{
power_supply_unregister(&olpc_bat);
power_supply_unregister(&olpc_ac);
platform_device_unregister(bat_pdev);
}
module_init(olpc_bat_init);
module_exit(olpc_bat_exit);
MODULE_AUTHOR("David Woodhouse <dwmw2@infradead.org>");
MODULE_LICENSE("GPL");
MODULE_DESCRIPTION("Battery driver for One Laptop Per Child 'XO' machine");