[ Upstream commit 6549c46af8551b346bcc0b9043f93848319acd5c ]
For linear regulators, the n_voltages should be (max - min) / step + 1.
Buck voltage from 1v to 3V, per step 100mV, and vout mask is 0x1f.
If value is from 20 to 31, the voltage will all be fixed to 3V.
And LDO also, just vout range is different from 1.2v to 3v, step is the
same. If value is from 18 to 31, the voltage will also be fixed to 3v.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Reviewed-by: ChiYuan Huang <cy_huang@richtek.com>
Link: https://lore.kernel.org/r/20210627080418.1718127-1-axel.lin@ingics.com
Signed-off-by: Mark Brown <broonie@kernel.org>
Signed-off-by: Sasha Levin <sashal@kernel.org>