Symmetric rate configuration can fail if the second stream starting tries
to apply the symmetric constraint before the first stream has got far
enough to pick a rate. Rather than try to enforce a nonsensical rate of
0Hz log a warning and allow the application to carry on. Things might go
wrong later on but the user will know about it and there's unlikely to be
lasting damage.
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Acked-by: Liam Girdwood <lrg@ti.com>