Add discussion of noise blanker in FST4 section of docs.
This commit is contained in:
parent
b194cc1a14
commit
954cf00b6c
@ -1,13 +1,15 @@
|
||||
Do not confuse FST4 with FT4, which has a very different purpose!
|
||||
FST4 is designed primarily for making weak-signal 2-way QSOs on the
|
||||
LF and MF bands. T/R periods from 15 s up to 1800 s are
|
||||
available. Longer T/R periods provide better sensitivity provided that the
|
||||
combined effects of Tx and Rx frequency instability and channel Doppler spread
|
||||
yield a received signal that remains coherent over the duration of
|
||||
several transmitted symbols. Generally speaking, Rx and Tx frequency changes
|
||||
available. Longer T/R periods provide better sensitivity only if
|
||||
Tx and Rx frequency instability and channel Doppler spread
|
||||
are small enough so that received signals
|
||||
remain phase coherent over periods spanning several transmitted symbols.
|
||||
Generally speaking, Rx and Tx frequency changes
|
||||
during the transmission and channel Doppler spread should each be small compared
|
||||
to the symbol keying rate shown for each T/R duration in Table 7 within section
|
||||
<<PROTOCOL_OVERVIEW,Protocol Specifications>>. For example, the keying rate for the 1800s T/R period is 0.089 Baud, so
|
||||
<<PROTOCOL_OVERVIEW,Protocol Specifications>>. For example, the keying rate for
|
||||
the 1800 s T/R period is 0.089 Baud, so
|
||||
successful operation using this T/R length requires Tx and Rx frequency
|
||||
stability better than 0.089 Hz over the duration of the 1800 s transmission in
|
||||
addition to channel Doppler spread smaller than 0.089 Hz.
|
||||
@ -33,15 +35,26 @@ decoding process (and of course will be undecodable). By checking
|
||||
further limit the decoding range to the setting of *F Tol* on
|
||||
either side of *Rx Freq*.
|
||||
|
||||
.Open a Wave File:
|
||||
A noise blanker can be enabled by setting the *NB* percentage to a non-zero value.
|
||||
This setting determines how many of the largest-amplitude samples will be
|
||||
blanked (zeroed) before the data is submitted to the decoder. Most users find
|
||||
that settings between 0% (no blanking) and 10% work best. If the noise
|
||||
blanker percentage is set to -1%, then the decoder will try 0, 5, 10, 15, and 20 %
|
||||
in succession. Similarly, a setting of -2% causes the decoder to loop over
|
||||
blanking percentages 0, 2, 4, ... 20 %. To save time, the multiple blanking
|
||||
percentages triggered by negative *NB* settings are tried only for signal
|
||||
candidates located near (within +/- 20 Hz) of the *Rx* frequency setting.
|
||||
|
||||
.Open a sample Wave File:
|
||||
|
||||
- Select *FST4* on the *Mode* menu. Set *T/R* to 60 s and *Decode | Deep*.
|
||||
- Set up the Wide Graph display so that it has settings appropriate for the FST4-60 mode.
|
||||
- Set *NB* (noise blanker) to 0%.
|
||||
- Set up the Wide Graph display with settings appropriate for the FST4-60 mode.
|
||||
For example, try *Bins/Pixel* 2 and *N Avg* 4. Set the *Start* frequency and the width of
|
||||
the Wide Graph to cover the entire frequency range that you want to decode. For this
|
||||
the Wide Graph to include the frequency range that you want to decode. For this
|
||||
example, make sure that *Start* is less than 1000 Hz and that the Wide Graph extends to above 1400 Hz.
|
||||
- Set *F Low* 1000, *F High* 1400. These settings define the decoder's frequency search range.
|
||||
- Open a sample Wave file using *File | Open* and select the file
|
||||
...\save\samples\FST4+FST4W\210115_0058.wav. When the file opens you should see something similar to the following screen shot:
|
||||
...\save\samples\FST4+FST4W\210115_0058.wav. After _WSJT-X_ has processed the file you should see something similar to the following screen shot:
|
||||
|
||||
image::FST4-1.png[align="left"]
|
||||
|
@ -20,6 +20,7 @@ scheduling behavior, you should select *Random* with this control.
|
||||
.Open a Wave File:
|
||||
|
||||
- Select *FST4W* on the *Mode* menu. Set *T/R* to 1800 s and *Decode | Deep*.
|
||||
- Set *NB* to 0%.
|
||||
- Select appropriate wide graph settings. For example, try *Bins/Pixel* 1,
|
||||
*Start* 1200 Hz and *N Avg* 150.
|
||||
- Open a sample Wave file using *File | Open* and select the file
|
||||
|