Commit Graph

2680 Commits

Author SHA1 Message Date
Joe Taylor
04b22ce250 Preparing to add solution for frequendy drift to q65_sync.f90. 2021-01-02 14:21:14 -05:00
Joe Taylor
bc58604d42 Allow optional frequency drift of simulated Q65 signals. 2021-01-02 13:09:47 -05:00
Joe Taylor
e5a8e80c49 Minor tweaks to Q^% decoding scheme. 2021-01-01 15:28:41 -05:00
Joe Taylor
6b351165f2 Re-introduce Q65 timer calls. Extend red sync baseline to minimum +/- 100 Hz. 2021-01-01 10:47:22 -05:00
Joe Taylor
8a4b5b6a40 Various tweaks to the Q65 decoder; new numbering of the end-of-line decoding flags. 2020-12-31 15:52:06 -05:00
Joe Taylor
bcbca02c08 Enforce Q65 ClrAvg action when requested. Tweak somne logic. 2020-12-30 16:12:02 -05:00
Joe Taylor
e07ba410c2 Fix a problem with access to apsym0() array. 2020-12-30 15:40:06 -05:00
Joe Taylor
5d7b5f83e2 Fix several more flaws in the way Q65 decodes are presented. 2020-12-30 15:05:02 -05:00
Joe Taylor
77a0e01b05 Allow for all AP types when averaging Q65, and for navg > 9. 2020-12-30 12:10:03 -05:00
Joe Taylor
91687c573b Fix the reporting of SNR for Q65 average decodes. 2020-12-30 11:02:49 -05:00
Joe Taylor
412422db17 Add 'q' to the Q65 end-of-line flags; label right text window for "Average decodes". 2020-12-30 10:42:27 -05:00
Joe Taylor
d81c01d23d Remove unneeded arguments from calls to q65_avg and q65_avg2. 2020-12-30 09:07:41 -05:00
Joe Taylor
057967a761 For Q65 nsg averaging, wrap nsave when it reaches MAXAVE. 2020-12-30 08:44:56 -05:00
Joe Taylor
b6d2002985 Q65 decoder mostly working now with all (A B C D) decoding types. 2020-12-29 16:41:48 -05:00
Joe Taylor
520a0c7cc0 Work in progress for Q65 decoder. 2020-12-28 18:53:13 -05:00
Joe Taylor
62074ab58f Much reworking of Q65 decoder. Have temporarily enabled all types of decoding passes. 2020-12-28 15:27:10 -05:00
Joe Taylor
30ab29d9e3 Work in progress, with lots of diagnostics. Do not use on the air! 2020-12-27 15:27:26 -05:00
Joe Taylor
48297e068b More work in ptogress ... 2020-12-27 14:14:10 -05:00
Joe Taylor
d246a23948 Work in progress on message averaging: save current status. 2020-12-27 11:35:55 -05:00
Joe Taylor
5c805dfb39 another realignment of red sync curve and convention for f0. 2020-12-27 10:35:04 -05:00
Joe Taylor
c8ace441f9 New files for Q65 message averaging. 2020-12-26 10:08:53 -05:00
Joe Taylor
3d042ee56f Work in progress, on Q65 message averaging. 2020-12-26 10:04:17 -05:00
Joe Taylor
d5957f51f9 Insert some (commented out) diagnostics. 2020-12-24 13:07:29 -05:00
Joe Taylor
171e466389 More work on Q65 message averaging. 2020-12-24 09:51:02 -05:00
Joe Taylor
844930fe75 Correct the frequency alignment of red sync curve. 2020-12-23 11:03:09 -05:00
Joe Taylor
c5a0de6210 Partial implementation of Q65 message averaging. 2020-12-23 09:47:11 -05:00
Joe Taylor
008cb37c16 Update test_q65 for having removed the T/F sync flag from q65sim command line. 2020-12-22 13:41:40 -05:00
Joe Taylor
408ac7bd0d Correct the reported f0 for Q65 signals. It was off by one tone spacing. 2020-12-22 13:21:31 -05:00
Joe Taylor
cac6577127 Extend the DT range for 30 s Q65 submodes to include EME delays. 2020-12-22 09:43:25 -05:00
Joe Taylor
83c917ac57 Don't allow previous values of DT, f0 to be displayed with a no-decode. 2020-12-21 15:59:33 -05:00
Joe Taylor
044aa80dc4 Remove all vestiges of the QRA64 mode. It has been replaced by Q65. 2020-12-21 15:07:53 -05:00
Joe Taylor
36a089de21 Remove the sync-test option from q65sim.f90. 2020-12-21 13:42:03 -05:00
Joe Taylor
44516dbbc1 Make the Q65 red sync curve at least 21 tone-spacings wide, even if FTol is smaller. 2020-12-21 13:33:54 -05:00
Joe Taylor
545079e951 Reorder the ibw loop in q65_loops.f90. 2020-12-20 21:43:30 -05:00
Joe Taylor
ddf727f351 Adjust a 3 dB offset in Q65 SNRs from list decodes. 2020-12-20 21:42:42 -05:00
Joe Taylor
1f33c857ac Measure fSpread from ccf1, then use resulting width to set effective ibwmin. 2020-12-19 13:25:51 -05:00
Joe Taylor
c7ca708569 Fix the problem with not honoring "Save Decoded" in Q65 mode. 2020-12-19 11:42:42 -05:00
Joe Taylor
f23129c33c Fix a problem with Q65 FTol range extending down below 0 Hz. 2020-12-19 11:25:18 -05:00
Joe Taylor
7096a548ec Correct a problem with estimating rms of ccf for Q65-300x submodes. 2020-12-19 10:42:27 -05:00
Joe Taylor
89ab3b0f01 Fix a bounds error with very small FTol. 2020-12-18 16:30:11 -05:00
Joe Taylor
450249dd4c Add a DT label to the Q65 red sync curve. 2020-12-18 16:19:01 -05:00
Joe Taylor
67b82c7666 Remove the klunky 2D sync plot. The red sync curve is better. 2020-12-18 16:00:33 -05:00
Joe Taylor
b3769bb6c8 For Q65, plot a red "Sync curve" in the Wide Graph. 2020-12-18 13:31:14 -05:00
Joe Taylor
d165532dc5 Oops! Committed the wrong version of q65_decode.f90. 2020-12-17 19:06:07 -05:00
Joe Taylor
8507a42655 Quasi-graphical display of the sync ccf(f0,DT). 2020-12-17 17:02:28 -05:00
Joe Taylor
6b8abe32b1 One more protection against too-large FTol. 2020-12-16 15:51:46 -05:00
Joe Taylor
a47ec75f56 Reformat the test_q65 headings and output. 2020-12-15 13:17:31 -05:00
Joe Taylor
0ee61205aa Disable diagnostic writing to 'fort.55' in CWD. 2020-12-15 11:37:48 -05:00
Joe Taylor
841bbac56e Increase the Q65 list decodes to include reports -50 to +49 dB. 2020-12-15 11:03:06 -05:00
Joe Taylor
3160e63dc7 Several minor tweaks to Q65 decoding. 2020-12-15 09:32:24 -05:00