These were using a hijacked custom spin box that was designed only for
letters i.e. submodes. Now there are two new custom spin boxes.
HistedSpinBox:- can be set with a list of integer values which the
step up and down will follow. Optionally limits the maximum and
minimum value to the upper and lower bounds of the values set. Note
that intermediate values are still valid.
RestrictedSpinBox:- more like a combo box because the provided values
are the only ones that can be set.
HintedSpinBox is used for the frequency tolerance and
RestrictedSpinBox is used for T/R period.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7698 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
More to come on this but should get Tab 2 basically working with
MSK144 running from a calling frequency.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7675 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Thanks to Mike, W9MDB, for this contribution.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7653 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Ctrl+M (Cmd+M) was being used as a menu shortcut and in key press
event handlers which leads to inconsistent behaviour on some
platforms. Removed menu action shortcut.
Also tidied up handling of the hide controls menu action by making it
a checkable action and using its checked state to store the control
hiding state.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7608 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
1. Level meter range increased to 0-90 dB.
2. Level meter reading is independent of slider setting.
3. For a trial period: thermometer bar goes red if a 16-bit sample
is within 5 dB A/D limit.
4. Slider can be used to adjust levels sent to waterfall.
5. Tx6 message is selected on program startup.
Thanks to W9MDB for most of this code.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7596 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
This builds on the static phase compensation in the MSK144 decoder and
the phase analysis and polynomial fitting capabilities also in teh
MSK144 decoder, by allowing captured data to be selected for phase
equalization from the WSJT-X UI.
Reads captured phase compensation curve estimate files containing
fitted polynomial coefficients and measured phase data from MSK144
receptions. Intent is to select a compensation curve that is from a
known transmitter like an SDR which have good phase linearity. Phase
plots and compensation polynomials may be viewed and compared with the
current compensation polynomial. A suitable polynomial can be applied
to be use in all further decoding of MSK144 signals.
Plots of the currently selected polynomial and its modified higher
order terms polynomial which is actually used in equalization (this
plot may be dropped - it is just for kicks at the moment). When a
captured phase analysis file is loaded plots of the measured phase and
the proposed best fit polynomial are shown.
Basic maintenance is also included allowing clearing and loading
captured plots and an option to revert to a flat no equalization
curve.
More to come on this as amplitude equalization is also possible, this
will probably be similar, maybe even plotted on the same graph with
dual axes for phase and amplitude. Amplitude correction from a
measured reference spectrum could be viewed and selected for
equalization for all modes. TBC...
This change also introduces the QCustomPlot 3rd party
widget. Currently this is statically linked from a qcp library built
by the WSJT-X CMake script. This will probably be migrated to a shared
object (DLL) build as a CMake external project, once some CMake script
re-factoring has been completed, which is more in line with the
QCustomPlot author's intentions. This will allow efficient reuse in
other tools shipped with WSJT-X.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7570 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
1. Menu item *Tools -> Execute frequency calibration cycle* is renamed and checkable. Cycling does not start until checked.
2. Ctrl+F10 now allows you to cycle manually through the list of calibration frequencies.
3. Calibration sequence lengths can be set to 5, 10, 15, or 30 s with the sbTR spinBox.
Also: don't set sbTR index to 0 when entering a slow mode.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7485 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
... rather than the working frequency.
Users set their working frequency and specify a calling frequency as a
kHz offset into the current Rx MHz with the main window spin box.
Calling CQ on the specified calling frequency is enabled by checking
the associated option.
Also enhanced the auto sequencing to handle short code 73 messages
correctly.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7339 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
2. Correct several more flaws in making GUI controls visible or invisible.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7170 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
This option, on by default, maintains backwards compatibility for
non-compound callsign holders. If switched off and they have
specified a 6 digit grid then it will be sent in the type 2 protocol
using two messages and a hashed callsign.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7053 ab8295b8-cf94-4d9e-aec4-7959e3be5d79