When using split operating and/or rig mode setting there is a delay
before PTT is asserted while the CAT commands are processed. There
will even be a small delay if CAT is only used for PTT. This change
waits for these commands to be completed before starting the user Tx
delay specified in the settings.
There is a notable exception to this in that DX Lab Suite Commander
does not give us a way of knowing when CAT commands have actually been
completed. This combined with the way that Commander spaces CAT
commands, rather than being paced by the rig's CAT responses, means
that delays of more than 1 second are likely. As most rigs suffer some
sort of ALC overshoot when PTT is asserted with audio already present,
it is strongly recommended not to use the DX Lab Suite Commander as a
rig control proxy if your rig may suffer ALC overshoot and you use an
external PA. Please note that using a typical RF power meter to detect
ALC overshoots is unwise as they are rarely fast enough. It is
probably wise to assume that all rigs suffer ALC overshoot since it is
very difficult to design an ALC loop that avoids it.
This change also increases the range of the "Settings->Advanced->Tx
Delay" spin box to 0s up to 2s.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7756 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
For FT8 mode:
1. Open LU 13 in the proper way.
2. Disable diagnostic LU 51.
3. Add keyboard shortcuts CTRL+Plus, CTRL-Minus, to adjust audio Tx frequency
in even 50 Hz steps.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7749 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
This feature is of limited benefit and causes unexpected behaviour on
rigs with lower than 1Hz resolution. Removed for simplicity.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7743 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
2. ft8d is now a bare-bones multi-decoder.
3. wsjt-x now includes the bare-bones multi-decoder for FT8.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7729 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
These were using a hijacked custom spin box that was designed only for
letters i.e. submodes. Now there are two new custom spin boxes.
HistedSpinBox:- can be set with a list of integer values which the
step up and down will follow. Optionally limits the maximum and
minimum value to the upper and lower bounds of the values set. Note
that intermediate values are still valid.
RestrictedSpinBox:- more like a combo box because the provided values
are the only ones that can be set.
HintedSpinBox is used for the frequency tolerance and
RestrictedSpinBox is used for T/R period.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7698 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Until the advanced band hopping scheduler is upgraded to work with T/R
periods other than 2 minutes this scheduler uses a strictly random
scheduler, except that Tx percentages less than 40 defer Tx periods
that would otherwise be consecutive.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7687 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
More to come on this but should get Tab 2 basically working with
MSK144 running from a calling frequency.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7675 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
The wide graph class handles 60m band behaviour of the minimum decoded
JT9 DF internally without leaking implementation details.
On 60m the lowest JT9 DF is always zero and the spin box to set it is
disabled. This reflects that 60m only has narrow channels and JT9
signals should share the same dial frequency as JT65 signals.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7668 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Ctrl+M (Cmd+M) was being used as a menu shortcut and in key press
event handlers which leads to inconsistent behaviour on some
platforms. Removed menu action shortcut.
Also tidied up handling of the hide controls menu action by making it
a checkable action and using its checked state to store the control
hiding state.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7608 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
1. Level meter range increased to 0-90 dB.
2. Level meter reading is independent of slider setting.
3. For a trial period: thermometer bar goes red if a 16-bit sample
is within 5 dB A/D limit.
4. Slider can be used to adjust levels sent to waterfall.
5. Tx6 message is selected on program startup.
Thanks to W9MDB for most of this code.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7596 ab8295b8-cf94-4d9e-aec4-7959e3be5d79