1. Level meter range increased to 0-90 dB.
2. Level meter reading is independent of slider setting.
3. For a trial period: thermometer bar goes red if a 16-bit sample
is within 5 dB A/D limit.
4. Slider can be used to adjust levels sent to waterfall.
5. Tx6 message is selected on program startup.
Thanks to W9MDB for most of this code.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7596 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
"JT65 nnnn JT9" blue line to 0 Hz. Now it also moves the spinner to
0 Hz, as it should have done. Subsequent QSY to another band will reset
the blue line and spinner to where they had been, before the QSY to 60 m.
Thanks to W9MDB for this patch.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7595 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Use a header format for polynomial coefficients that includes the
valid X range in scaled terms and a count of the number of
coefficients.
Use double precision consistently for polynomial coefficients. This
includes formatting with sufficient DPs when writing to files.
Many changes to the equalization plots, more to come.
Add error handling for reading coefficient, plot and filter
files. This includes being backward compatible for old format
refspec.dat files with no header.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7578 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
This builds on the static phase compensation in the MSK144 decoder and
the phase analysis and polynomial fitting capabilities also in teh
MSK144 decoder, by allowing captured data to be selected for phase
equalization from the WSJT-X UI.
Reads captured phase compensation curve estimate files containing
fitted polynomial coefficients and measured phase data from MSK144
receptions. Intent is to select a compensation curve that is from a
known transmitter like an SDR which have good phase linearity. Phase
plots and compensation polynomials may be viewed and compared with the
current compensation polynomial. A suitable polynomial can be applied
to be use in all further decoding of MSK144 signals.
Plots of the currently selected polynomial and its modified higher
order terms polynomial which is actually used in equalization (this
plot may be dropped - it is just for kicks at the moment). When a
captured phase analysis file is loaded plots of the measured phase and
the proposed best fit polynomial are shown.
Basic maintenance is also included allowing clearing and loading
captured plots and an option to revert to a flat no equalization
curve.
More to come on this as amplitude equalization is also possible, this
will probably be similar, maybe even plotted on the same graph with
dual axes for phase and amplitude. Amplitude correction from a
measured reference spectrum could be viewed and selected for
equalization for all modes. TBC...
This change also introduces the QCustomPlot 3rd party
widget. Currently this is statically linked from a qcp library built
by the WSJT-X CMake script. This will probably be migrated to a shared
object (DLL) build as a CMake external project, once some CMake script
re-factoring has been completed, which is more in line with the
QCustomPlot author's intentions. This will allow efficient reuse in
other tools shipped with WSJT-X.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7570 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Allow band drop down list to be used to select FreqCal frequencies,
also resets position in automatic cycle. Tidy up some unnecessary
code.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7486 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
1. Menu item *Tools -> Execute frequency calibration cycle* is renamed and checkable. Cycling does not start until checked.
2. Ctrl+F10 now allows you to cycle manually through the list of calibration frequencies.
3. Calibration sequence lengths can be set to 5, 10, 15, or 30 s with the sbTR spinBox.
Also: don't set sbTR index to 0 when entering a slow mode.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7485 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Rx DF is now "real-time" adjusting the rig in concert with the
monitored DF.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7465 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Some default time signals have been added to the frequency list so a
base set can be obtained by resetting the frequency list,
alternatively they can be added ad hoc in the normal fashion.
FreqCal mode behavior is to select the lowest cal frequency upon
entering FreqCal mode and cycling through each cal frequency
repeatedly. Ctrl+F10 jumps directly to the next higher frequency.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7463 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Deepest decode level should be selected automatically when switching
to JT4 or JT65 when VHF & up mode is on and either of averaging or
deep search are enabled.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7456 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
only when 73 is sent. Revert to that well-established behavior.
2. Correct the logic that detects short-form RO, RRR, and 73 messages in
JT65 VHF modes and color-highlights the Tx message box.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7442 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
2. Don't update the "Last Tx" message until current transmission is complete.
These suggestions from W9MDB.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7429 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
2. Send emedelay (now 0 or 2.5) to QRA64 decoder.
3. Tweaks to sync64, making it better for QRA64A.
4. Mainwindow MessageBox if it attempts to open a file with wrong format.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7424 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Sub mode and fast mode flag are added to the UDP Status message and
Status messages after appropriate UI changes. MSK144 decodes produce
UDP Decode messages. Fast JT9 messages are treated similarly.
Currently ISCAT decodes are not posted as UDP Decode messages as they
do not fit well with the model.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7389 ab8295b8-cf94-4d9e-aec4-7959e3be5d79