Ctrl+M (Cmd+M) was being used as a menu shortcut and in key press
event handlers which leads to inconsistent behaviour on some
platforms. Removed menu action shortcut.
Also tidied up handling of the hide controls menu action by making it
a checkable action and using its checked state to store the control
hiding state.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7608 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
1. Level meter range increased to 0-90 dB.
2. Level meter reading is independent of slider setting.
3. For a trial period: thermometer bar goes red if a 16-bit sample
is within 5 dB A/D limit.
4. Slider can be used to adjust levels sent to waterfall.
5. Tx6 message is selected on program startup.
Thanks to W9MDB for most of this code.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7596 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
This builds on the static phase compensation in the MSK144 decoder and
the phase analysis and polynomial fitting capabilities also in teh
MSK144 decoder, by allowing captured data to be selected for phase
equalization from the WSJT-X UI.
Reads captured phase compensation curve estimate files containing
fitted polynomial coefficients and measured phase data from MSK144
receptions. Intent is to select a compensation curve that is from a
known transmitter like an SDR which have good phase linearity. Phase
plots and compensation polynomials may be viewed and compared with the
current compensation polynomial. A suitable polynomial can be applied
to be use in all further decoding of MSK144 signals.
Plots of the currently selected polynomial and its modified higher
order terms polynomial which is actually used in equalization (this
plot may be dropped - it is just for kicks at the moment). When a
captured phase analysis file is loaded plots of the measured phase and
the proposed best fit polynomial are shown.
Basic maintenance is also included allowing clearing and loading
captured plots and an option to revert to a flat no equalization
curve.
More to come on this as amplitude equalization is also possible, this
will probably be similar, maybe even plotted on the same graph with
dual axes for phase and amplitude. Amplitude correction from a
measured reference spectrum could be viewed and selected for
equalization for all modes. TBC...
This change also introduces the QCustomPlot 3rd party
widget. Currently this is statically linked from a qcp library built
by the WSJT-X CMake script. This will probably be migrated to a shared
object (DLL) build as a CMake external project, once some CMake script
re-factoring has been completed, which is more in line with the
QCustomPlot author's intentions. This will allow efficient reuse in
other tools shipped with WSJT-X.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7570 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
1. Menu item *Tools -> Execute frequency calibration cycle* is renamed and checkable. Cycling does not start until checked.
2. Ctrl+F10 now allows you to cycle manually through the list of calibration frequencies.
3. Calibration sequence lengths can be set to 5, 10, 15, or 30 s with the sbTR spinBox.
Also: don't set sbTR index to 0 when entering a slow mode.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7485 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
... rather than the working frequency.
Users set their working frequency and specify a calling frequency as a
kHz offset into the current Rx MHz with the main window spin box.
Calling CQ on the specified calling frequency is enabled by checking
the associated option.
Also enhanced the auto sequencing to handle short code 73 messages
correctly.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7339 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
2. Correct several more flaws in making GUI controls visible or invisible.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7170 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
This option, on by default, maintains backwards compatibility for
non-compound callsign holders. If switched off and they have
specified a 6 digit grid then it will be sent in the type 2 protocol
using two messages and a hashed callsign.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7053 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Fix the improper display of "Fast" checkbox.
Disable "CQ nnn" checkbox if MyCall is not K1JT or K9AN.
Use AppDir as path to execute the LDPC encode program.
Don't display submodes in mode label for JTMSK, MSK144.
Make Rx Freq spinner invisible in MSK144 mode.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7001 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
The watchdog configuration is now a spin box of minutes with a special
first value of disabled. WSJT-X counts down minutes on the minute, if
the countdown reaches zero any attempt to transmit is aborted. The
countdown is reset by any mouse press or key press event inside the
main window or if the Tx message changes (auto sequencing).
The status bar now shows the Tx watchdog countdown if it is
active. This information is shown to the right of the progress bar
text.
The warning message boxes triggered within the GUI update routine now
no longer block the GUI updates.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@6840 ab8295b8-cf94-4d9e-aec4-7959e3be5d79