When "Auto Grid" is checked in "Settings->General" UDP messages of
type "Location" will update a temporary DE grid square. The intent is
to allow an external application joining the WSJT-X UDP message
protocol to dynamically update the DE grid during mobile operation.
This change also tidies up some outstanding issues around logging the
operator call.
This change adds a new UDP message "Logged ADIF" that is emitted in
parallel with "QSO Logged" messages. The new message is valid ADIF
file format and contains the logged QSO fields. The intent is that
basic UDP server applications might already have ADIF log record
capture capabilities and could use this message to feed existing ADIF
parsing routines to log QSOs. All that should be needed is to identify
this message type and the single field is ADIF compatible ASCII.
Thanks to Brian, N9ADG, for the patches that lead to these
enhancements.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8454 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
1. Insert dummy report when Hound is called by complex-callsign Fox.
2. Allow Fox to transmit anywhere between 300 and 900 Hz.
3. Restrict randomized Hound freq to the range 1000 - 3000 Hz.
4. Suppress Fox signals that would be duplicates.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8376 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Operator callsign is sent to DIF log if not empty.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8267 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
This change opens up all keyboard modifier options to UDP Reply
messages as well as double-clicks of decoded messages.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8168 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Measure check box added to FreqCal mode, check to record to fmt.all
with current calibration correction disabled, uncheck to see the
impact of the current calibration parameters.
The fmt.all file is now optionally renamed to fmt.bak when a
calibration solution is accepted. This allows users to preserve an
fmt.all file that they might have edited for best fit.
A calibration procedure might proceed thus:-
1) select FreqCal mode,
2) step through suggested calibration test frequencies deleting those
that have no usable signal,
3) enable "Menu->Tools->Execute frequency calibration cycle" and check
that suitable signals are present,
4) select a suitable FTol and T/R period,
5) check "Measure" and let the cycle complete a few times to gather
data,
6) uncheck "Measure" to complete the data capture, optionally tidy the
fmt.all file with your favourite editor,
7) push "Menu->Tools->Solve for calibration parameters" and accept if
you like what you see,
8) sit back and admire your accurately frequency calibrated station.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8167 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
1. Checkbox "Double-click on call sets Tx and Rx freqs" has been removed
from the Settings -> General tab.
2. Checkbox "Lock Tx Freq" on main window is relabled "Hold Tx Freq".
3. Behavior now defaults to the "simplex" behavior in use up to code
revision r8123. In particular, double-clicking on decoded mesages
that do not contain your own call moves both Rx and Tx frequencies.
If the first callsign is your own call, only Rx freq moves.
4. If "Hold Tx Freq" is checked, double-clicking on decoded messages
moves the Rx frequency; Tx frequency is moved only if CTRL was held
down.
5. Clicking on the waterfall moves Rx and Tx frequencies as before:
Rx only on a simple click, Tx only on SHIFT-click, and both on
CTRL-click. This happens even if "Hold Tx Freq" is checked (which
is why this box is no longer labeled "Lock Tx Freq").
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8146 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
1. Checkbox "Lock Tx=Rx" is now labeled "Lock Tx Freq", and its meaning is
quite different. If checked, the audio Tx frequency cannot be changed.
It's like the "Lock" function on some transceivers.
2. Clicking on the Wide Graph waterfall and on lines of decoded text now
behave as follows:
Click on Action
---------------------------------------------------------------------
Waterfall: Click to set Rx frequency
Shift-click to set Tx frequency
Ctrl-click to set Rx and Tx frequencies
If Lock Tx Freq is checked, Tx freq does not move
Double-click to set Rx frequency and decode there
Decoded Text: Double-click to copy transmitting callsign to DX Call
and locator to DX Grid; change Rx frequency to decoded
signal's frequency; generate standard messages.
Tx frequency is not changed unless Ctrl is held down
and Lock Tx Freq not checked.
If this experimental behavior is adopted, some descriptions in the
User Guide and Special Mouse Commands will need to be updated.
3. Starting to implement a new function on the Tools menu,
"Solve for calibration parameters". This is not yet finished;
DO NOT USE in its present form.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8125 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
This allows UDP servers to emulate keyboard modified double-clicks on
decoded messages, E.g. ALT+double-click for replying to a CQ or QRZ
call without changing ones Tx frequency offset.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8103 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Right-click either decoded text window to erase its contents. The
"Erase" button on the main UI still operates as before although it is
implemented differently now.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8090 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
The main window font has to be set after main window construction
otherwise the menu bar font does not get set.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8077 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Double-clicks on 73 messages fixed. Fixed issue with incorrect decode
being selected by double-click. Refined auto-sequencing sign off
handling, any 73 or rr73 free text near Rx or Tx frequency taken as a
73 from QSO partner but if a standard message then must be from QSO
partner.
Moved functionality from MainWindow to DecodedText class.
More efficient picking of messages from decoded text windows by
extracting the text block directly.
Tighten up use of RR73 and skipping Tx1, these are now disabled for
relevant compound calls where they would break the QSO exchange.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8056 ab8295b8-cf94-4d9e-aec4-7959e3be5d79