Enable or disable by double-clicking the Tx4 button or the adjacent
radio button. Is auto disabled by a band change as it is expected that
the user reassess the conditions to see if message repetitions are
unlikely to be needed.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7950 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Enable and disable by double-clicking the Tx1 button or the adjacent
radio button. Tx1 message shows grayed out when the Tx1 message is
elided.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7949 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
moves the Rx frequency to theirs, this facilitates calling a station
who is busy and may have many callers on their frequency. Updated the
corresponding mouse shortcuts help text.
Allow for times with seconds when parsing fast mode and FT8 decodes.
Exclude the RR73 grid square from and grid validation or matching, it
is not a grid square any more as far as WSJT-X is concerned, it is an
RRR substitute.
Add a simple state machine for QSO progress such that replies and
auto-sequencing can be better controlled.
Get compound callsign edge cases working again and allow QSOs from and
to compound callsign holders working in as many situations as possible
including auto-sequencing and FT8 auto-reply mode. This does mean
that a "DE W6/K1ABC DM93" type message close to a callers Tx or Rx
frequency will be taken as a reply to a CQ call despite it not being
explicitly addressed back to the CQ caller. Compound callsigns should
work in MSK144 contest mode also as well as in short code modes with
some minor restrictions (short codes will not be used where
configuration demands that a message be used to send a full compound
callsign).
Auto sequencing has been made generic such that it can be used for
more than one mode if desired.
Allow the use of free text messages to sign off in auto sequenced QSOs
without the message being overwritten by the sequencer. Double click
actions have been added to the Tx5 radio and push buttons to revert
back to the default standard 73 message.
Make DisplayText class interface more idiomatic C++ and simplify a
bit.
Fixed some displayed widget arrangements for different modes and
sub-modes so that they are consistent when starting up and when
switching mode or sub-mode.
This is a big change which has been extensively tested but no doubt
there will also be some new defects introduced.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7939 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Now equlization tools as it covers both amplitude and phase
equalization.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7875 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
These were using a hijacked custom spin box that was designed only for
letters i.e. submodes. Now there are two new custom spin boxes.
HistedSpinBox:- can be set with a list of integer values which the
step up and down will follow. Optionally limits the maximum and
minimum value to the upper and lower bounds of the values set. Note
that intermediate values are still valid.
RestrictedSpinBox:- more like a combo box because the provided values
are the only ones that can be set.
HintedSpinBox is used for the frequency tolerance and
RestrictedSpinBox is used for T/R period.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7698 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
More to come on this but should get Tab 2 basically working with
MSK144 running from a calling frequency.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7675 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Thanks to Mike, W9MDB, for this contribution.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7653 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Ctrl+M (Cmd+M) was being used as a menu shortcut and in key press
event handlers which leads to inconsistent behaviour on some
platforms. Removed menu action shortcut.
Also tidied up handling of the hide controls menu action by making it
a checkable action and using its checked state to store the control
hiding state.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7608 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
1. Level meter range increased to 0-90 dB.
2. Level meter reading is independent of slider setting.
3. For a trial period: thermometer bar goes red if a 16-bit sample
is within 5 dB A/D limit.
4. Slider can be used to adjust levels sent to waterfall.
5. Tx6 message is selected on program startup.
Thanks to W9MDB for most of this code.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7596 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
This builds on the static phase compensation in the MSK144 decoder and
the phase analysis and polynomial fitting capabilities also in teh
MSK144 decoder, by allowing captured data to be selected for phase
equalization from the WSJT-X UI.
Reads captured phase compensation curve estimate files containing
fitted polynomial coefficients and measured phase data from MSK144
receptions. Intent is to select a compensation curve that is from a
known transmitter like an SDR which have good phase linearity. Phase
plots and compensation polynomials may be viewed and compared with the
current compensation polynomial. A suitable polynomial can be applied
to be use in all further decoding of MSK144 signals.
Plots of the currently selected polynomial and its modified higher
order terms polynomial which is actually used in equalization (this
plot may be dropped - it is just for kicks at the moment). When a
captured phase analysis file is loaded plots of the measured phase and
the proposed best fit polynomial are shown.
Basic maintenance is also included allowing clearing and loading
captured plots and an option to revert to a flat no equalization
curve.
More to come on this as amplitude equalization is also possible, this
will probably be similar, maybe even plotted on the same graph with
dual axes for phase and amplitude. Amplitude correction from a
measured reference spectrum could be viewed and selected for
equalization for all modes. TBC...
This change also introduces the QCustomPlot 3rd party
widget. Currently this is statically linked from a qcp library built
by the WSJT-X CMake script. This will probably be migrated to a shared
object (DLL) build as a CMake external project, once some CMake script
re-factoring has been completed, which is more in line with the
QCustomPlot author's intentions. This will allow efficient reuse in
other tools shipped with WSJT-X.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7570 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
1. Menu item *Tools -> Execute frequency calibration cycle* is renamed and checkable. Cycling does not start until checked.
2. Ctrl+F10 now allows you to cycle manually through the list of calibration frequencies.
3. Calibration sequence lengths can be set to 5, 10, 15, or 30 s with the sbTR spinBox.
Also: don't set sbTR index to 0 when entering a slow mode.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7485 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
... rather than the working frequency.
Users set their working frequency and specify a calling frequency as a
kHz offset into the current Rx MHz with the main window spin box.
Calling CQ on the specified calling frequency is enabled by checking
the associated option.
Also enhanced the auto sequencing to handle short code 73 messages
correctly.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7339 ab8295b8-cf94-4d9e-aec4-7959e3be5d79