This change opens up all keyboard modifier options to UDP Reply
messages as well as double-clicks of decoded messages.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8168 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Measure check box added to FreqCal mode, check to record to fmt.all
with current calibration correction disabled, uncheck to see the
impact of the current calibration parameters.
The fmt.all file is now optionally renamed to fmt.bak when a
calibration solution is accepted. This allows users to preserve an
fmt.all file that they might have edited for best fit.
A calibration procedure might proceed thus:-
1) select FreqCal mode,
2) step through suggested calibration test frequencies deleting those
that have no usable signal,
3) enable "Menu->Tools->Execute frequency calibration cycle" and check
that suitable signals are present,
4) select a suitable FTol and T/R period,
5) check "Measure" and let the cycle complete a few times to gather
data,
6) uncheck "Measure" to complete the data capture, optionally tidy the
fmt.all file with your favourite editor,
7) push "Menu->Tools->Solve for calibration parameters" and accept if
you like what you see,
8) sit back and admire your accurately frequency calibrated station.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8167 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
1. Checkbox "Double-click on call sets Tx and Rx freqs" has been removed
from the Settings -> General tab.
2. Checkbox "Lock Tx Freq" on main window is relabled "Hold Tx Freq".
3. Behavior now defaults to the "simplex" behavior in use up to code
revision r8123. In particular, double-clicking on decoded mesages
that do not contain your own call moves both Rx and Tx frequencies.
If the first callsign is your own call, only Rx freq moves.
4. If "Hold Tx Freq" is checked, double-clicking on decoded messages
moves the Rx frequency; Tx frequency is moved only if CTRL was held
down.
5. Clicking on the waterfall moves Rx and Tx frequencies as before:
Rx only on a simple click, Tx only on SHIFT-click, and both on
CTRL-click. This happens even if "Hold Tx Freq" is checked (which
is why this box is no longer labeled "Lock Tx Freq").
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8146 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
1. Checkbox "Lock Tx=Rx" is now labeled "Lock Tx Freq", and its meaning is
quite different. If checked, the audio Tx frequency cannot be changed.
It's like the "Lock" function on some transceivers.
2. Clicking on the Wide Graph waterfall and on lines of decoded text now
behave as follows:
Click on Action
---------------------------------------------------------------------
Waterfall: Click to set Rx frequency
Shift-click to set Tx frequency
Ctrl-click to set Rx and Tx frequencies
If Lock Tx Freq is checked, Tx freq does not move
Double-click to set Rx frequency and decode there
Decoded Text: Double-click to copy transmitting callsign to DX Call
and locator to DX Grid; change Rx frequency to decoded
signal's frequency; generate standard messages.
Tx frequency is not changed unless Ctrl is held down
and Lock Tx Freq not checked.
If this experimental behavior is adopted, some descriptions in the
User Guide and Special Mouse Commands will need to be updated.
3. Starting to implement a new function on the Tools menu,
"Solve for calibration parameters". This is not yet finished;
DO NOT USE in its present form.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8125 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
This allows UDP servers to emulate keyboard modified double-clicks on
decoded messages, E.g. ALT+double-click for replying to a CQ or QRZ
call without changing ones Tx frequency offset.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8103 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Right-click either decoded text window to erase its contents. The
"Erase" button on the main UI still operates as before although it is
implemented differently now.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8090 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
The main window font has to be set after main window construction
otherwise the menu bar font does not get set.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8077 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Double-clicks on 73 messages fixed. Fixed issue with incorrect decode
being selected by double-click. Refined auto-sequencing sign off
handling, any 73 or rr73 free text near Rx or Tx frequency taken as a
73 from QSO partner but if a standard message then must be from QSO
partner.
Moved functionality from MainWindow to DecodedText class.
More efficient picking of messages from decoded text windows by
extracting the text block directly.
Tighten up use of RR73 and skipping Tx1, these are now disabled for
relevant compound calls where they would break the QSO exchange.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8056 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
73 messages from other QSOs on frequency should now be ignored rather
than being processed.
Also some long overdue refactoring and tidying of non-idiomatic C++
code in the logbook directory.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8047 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
This means that "CQ DX", "CQ VT", etc., will be presistent until changed back.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8035 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Note that reverting to v1.7 will invalidate any saved working
frequencies from v1.8 but proceeding to v1.8 again will present a
reset set of working frequencies i.e. any user defined entries in v1.8
will be lost of a v1.8 -> v1.7 -> v1.8 transition is made.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8018 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
FT8 auto-stop will only react to messages within +/- 50Hz of our Tx
frequency.
Auto-sequence on "DE ..." and free text 73 messages will respond if
they are within 25Hz of our Tx or Rx frequency.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7970 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Bad idea, need to find a better way to extend grids to 6-digits from
CALL3.TXT.
This reverts commit r7959
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7965 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Enable or disable by double-clicking the Tx4 button or the adjacent
radio button. Is auto disabled by a band change as it is expected that
the user reassess the conditions to see if message repetitions are
unlikely to be needed.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7950 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Enable and disable by double-clicking the Tx1 button or the adjacent
radio button. Tx1 message shows grayed out when the Tx1 message is
elided.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7949 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
moves the Rx frequency to theirs, this facilitates calling a station
who is busy and may have many callers on their frequency. Updated the
corresponding mouse shortcuts help text.
Allow for times with seconds when parsing fast mode and FT8 decodes.
Exclude the RR73 grid square from and grid validation or matching, it
is not a grid square any more as far as WSJT-X is concerned, it is an
RRR substitute.
Add a simple state machine for QSO progress such that replies and
auto-sequencing can be better controlled.
Get compound callsign edge cases working again and allow QSOs from and
to compound callsign holders working in as many situations as possible
including auto-sequencing and FT8 auto-reply mode. This does mean
that a "DE W6/K1ABC DM93" type message close to a callers Tx or Rx
frequency will be taken as a reply to a CQ call despite it not being
explicitly addressed back to the CQ caller. Compound callsigns should
work in MSK144 contest mode also as well as in short code modes with
some minor restrictions (short codes will not be used where
configuration demands that a message be used to send a full compound
callsign).
Auto sequencing has been made generic such that it can be used for
more than one mode if desired.
Allow the use of free text messages to sign off in auto sequenced QSOs
without the message being overwritten by the sequencer. Double click
actions have been added to the Tx5 radio and push buttons to revert
back to the default standard 73 message.
Make DisplayText class interface more idiomatic C++ and simplify a
bit.
Fixed some displayed widget arrangements for different modes and
sub-modes so that they are consistent when starting up and when
switching mode or sub-mode.
This is a big change which has been extensively tested but no doubt
there will also be some new defects introduced.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7939 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Now equlization tools as it covers both amplitude and phase
equalization.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7875 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
This change also adds seconds resolution to log files and log QSO
fields.
This change makes the log QSO dialog more layout friendly and uses a
QDateTimeEdit for QSO start and end times.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7827 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Working frequencies can be for all regions or for individual IARU
regions. This allows each mode band tuple to have one or more working
frequencies which can include local ones only offered when the user
configures their IARU region.
Change working frequency default suggestions to better fit in
FT8. General rule is FT8 is at JT65 -2kHz except where that is not
possible e.g. where that would fall into a segment not allocated for
narrow band data modes. For tight bands like top band sqeeze existing
JT65 and JT allocations to allow space for FT8.
NOTE: this change changes the WSPR frequency on 80m to allow access to
JA stations that currently have no allocation where it was placed.
ALSO NOTE: the JT65 and JT9 frequencies for 80m move down 6 kHz, again
to accommodate region 3 users. Other appliactions not within our
control should be asked to move in step when 1.8.0 is released.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7810 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
When using split operating and/or rig mode setting there is a delay
before PTT is asserted while the CAT commands are processed. There
will even be a small delay if CAT is only used for PTT. This change
waits for these commands to be completed before starting the user Tx
delay specified in the settings.
There is a notable exception to this in that DX Lab Suite Commander
does not give us a way of knowing when CAT commands have actually been
completed. This combined with the way that Commander spaces CAT
commands, rather than being paced by the rig's CAT responses, means
that delays of more than 1 second are likely. As most rigs suffer some
sort of ALC overshoot when PTT is asserted with audio already present,
it is strongly recommended not to use the DX Lab Suite Commander as a
rig control proxy if your rig may suffer ALC overshoot and you use an
external PA. Please note that using a typical RF power meter to detect
ALC overshoots is unwise as they are rarely fast enough. It is
probably wise to assume that all rigs suffer ALC overshoot since it is
very difficult to design an ALC loop that avoids it.
This change also increases the range of the "Settings->Advanced->Tx
Delay" spin box to 0s up to 2s.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7756 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
These were using a hijacked custom spin box that was designed only for
letters i.e. submodes. Now there are two new custom spin boxes.
HistedSpinBox:- can be set with a list of integer values which the
step up and down will follow. Optionally limits the maximum and
minimum value to the upper and lower bounds of the values set. Note
that intermediate values are still valid.
RestrictedSpinBox:- more like a combo box because the provided values
are the only ones that can be set.
HintedSpinBox is used for the frequency tolerance and
RestrictedSpinBox is used for T/R period.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7698 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
More to come on this but should get Tab 2 basically working with
MSK144 running from a calling frequency.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@7675 ab8295b8-cf94-4d9e-aec4-7959e3be5d79