parameter (KK=49) !Information bits parameter (ND1=62) !Data symbols before sync waveform parameter (ND2=63) !Data symbols after sync waveform parameter (ND=ND1+ND2) !Total data symbols (125) parameter (NS=23) !Sync symbols (for length) parameter (NSPS=1024) !Samples per symbol at 12000 S/s parameter (NSYNC=NS*NSPS) !Samples in sync waveform (23,552) parameter (NZ=NSPS*(ND+NS)) !Samples in full Tx waveform (151,552) parameter (NMAX=15*12000) !Samples in iwave (180,000) parameter (NFFT=32768) !Length of FFT for sync waveform parameter (NFFT1=2*NSPS) !Length of FFTs for symbol spectra parameter (MM=7) !Bits per symbol parameter (NQ=2**MM) !Q, number of MFSK tones parameter (NN=127) !Our code is (127,51) parameter (NFZ=3) !First zero