WSJT-X/doc/user_guide/en/tutorial-wide-graph-settings.adoc
Bill Somerville 0ba0977aa2 User Guide localization
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@6341 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
2016-01-02 22:30:12 +00:00

14 lines
333 B
Plaintext

// Status=review
- *Bins/Pixel* = 4
- *JT65 .... JT9* = 2500
- *Start* = 200 Hz
- *N Avg* = 5
- *Palette* = Digipan
- *Flatten* = checked
- Select *Cumulative* for data display
- *Gain* and *Zero* sliders set near midscale
- Use the mouse to adjust the width of the *Wide Graph* so that its
upper frequency limit is about 2400 Hz.