17e028700f
Improved rule activation to include timeslot and resets, as well as not activating rules already activated, etc.
50 lines
3.2 KiB
Python
50 lines
3.2 KiB
Python
'''
|
|
THIS EXAMPLE WILL NOT WORK AS IT IS - YOU MUST SPECIFY YOUR OWN VALUES!!!
|
|
|
|
This file is organized around the "Conference Bridges" that you wish to use. If you're a c-Bridge
|
|
person, think of these as "bridge groups". You might also liken them to a "reflector". If a particular
|
|
system is "ACTIVE" on a particular conference bridge, any traffid from that system will be sent
|
|
to any other system that is active on the bridge as well. This is not an "end to end" method, because
|
|
each system must independently be activated on the bridge.
|
|
|
|
The first level (e.g. "WORLDWIDE" or "STATEWIDE" in the examples) is the name of the conference
|
|
bridge. This is any arbitrary ASCII text string you want to use. Under each conference bridge
|
|
definition are the following items -- one line for each HBSystem as defined in the main HBlink
|
|
configuration file.
|
|
|
|
* SYSTEM - The name of the sytem as listed in the main hblink configuration file (e.g. hblink.cfg)
|
|
This MUST be the exact same name as in the main config file!!!
|
|
* TS - Timeslot used for matching traffic to this confernce bridge
|
|
* TGID - Talkgroup ID used for matching traffic to this conference bridge
|
|
* ON and OFF are LISTS of Talkgroup IDs used to trigger this system off and on. Even if you
|
|
only want one (as shown in the ON example), it has to be in list format. None can be
|
|
handled with an empty list, such as " 'ON': [] ".
|
|
* TO_TYPE is timeout type. If you want to use timers, ON means when it's turned on, it will
|
|
turn off afer the timout period and OFF means it will turn back on after the timout
|
|
period. If you don't want to use timers, set it to anything else, but 'NONE' might be
|
|
a good value for documentation!
|
|
* TIMOUT is a value in minutes for the timout timer. No, I won't make it 'seconds', so don't
|
|
ask. Timers are performance "expense".
|
|
* RESET is a list of Talkgroup IDs that, in addition to the ON and OFF lists will cause a running
|
|
timer to be reset. This is useful if you are using different TGIDs for voice traffic than
|
|
triggering. If you are not, there is NO NEED to use this feature.
|
|
'''
|
|
|
|
BRIDGES = {
|
|
'WORLDWIDE': [
|
|
{'SYSTEM': 'MASTER-1', 'TS': 1, 'TGID': 1, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'ON', 'ON': [2,], 'OFF': [9,10], 'RESET': []},
|
|
{'SYSTEM': 'CLIENT-1', 'TS': 1, 'TGID': 3100, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'ON', 'ON': [2,], 'OFF': [9,10], 'RESET': []},
|
|
],
|
|
'ENGLISH': [
|
|
{'SYSTEM': 'MASTER-1', 'TS': 1, 'TGID': 13, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'NONE', 'ON': [3,], 'OFF': [8,10], 'RESET': []},
|
|
{'SYSTEM': 'CLIENT-2', 'TS': 1, 'TGID': 13, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'NONE', 'ON': [3,], 'OFF': [8,10], 'RESET': []},
|
|
],
|
|
'STATEWIDE': [
|
|
{'SYSTEM': 'MASTER-1', 'TS': 2, 'TGID': 3129, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'NONE', 'ON': [4,], 'OFF': [7,10], 'RESET': []},
|
|
{'SYSTEM': 'CLIENT-2', 'TS': 2, 'TGID': 3129, 'ACTIVE': True, 'TIMEOUT': 2, 'TO_TYPE': 'NONE', 'ON': [4,], 'OFF': [7,10], 'RESET': []},
|
|
]
|
|
}
|
|
|
|
if __name__ == '__main__':
|
|
from pprint import pprint
|
|
pprint(BRIDGES) |