Spectrum markers management

The spectrum markers are controlled with this dialog. Note that spectrum markers will effectively show on the spectrum display only when it is active (shows some data).

General interface

Spectrum Markers dialog

1. Sub-dialog selection

The complete dialog is split into tabs:

  • Hist for histogram (spectrum line) markers
  • Wat for waterfall markers
  • Anno for annotation markers

2. Markers set selection

This lets you selects which markers are displayed

  • None: no markers are displayed
  • Spec: spectrum markers (histogram and waterfall) are displayed
  • Anno: spectrum annotations are displayed

Histogram markers tab

Spectrum Markers histogram dialog

1. Marker frequency

Use this frequency dial to set the marker frequency in Hz

2. Center marker frequency

Push this button to move the marker at the center of the current spectrum

3. Marker color

The marker color is displayed here. You can click on the square to open a standard color selection dialog to select the marker color. Note that it selects the color of the text display of the marker the crosshairs remain in white color.

4. Marker show

Toggles marker display on the spectrum

5. Marker selection

Turn the dial button to select the marker being set up. The index of the marker appears at left.

6. Swap marker with reference marker (index 0)

Push this button to swap the current marker with marker at index 0. The marker at index 0 is the reference marker. Note that the colors are not swapped so that the marker color is associated to its index and not the marker itself.

7. Add/Remove marker

  • Press the "+" button to add a new marker with a maximum of 4 markers.
  • Press the "-" button to remove the current marker. When reference marker (index 0) is removed the marker at index 1 if it exists replaces it and thus is made the reference marker.

8. Power hold reset

When the power max hold is selected (9) this button resets the max hold

9. Marker type

This combo lets you select the type of marker:

  • Man: manual power set. The value is set with the next control (10)
  • Cur: current power. The marker will move according to the current power at the marker frequency
  • Max: max hold. The marker will move according to the maximum power at the marker frequency. Use button (8) to reset.

10. Manual (fixed) power

Use this slider to adjust the power position of the marker. The units are in dB irrespective of the linear or log set of the spectrum display.

Waterfall markers tab

Spectrum Markers waterfall dialog

1. Marker frequency

Use this frequency dial to set the marker frequency in Hz

2. Center marker frequency

Push this button to move the marker at the center of the spectrum

3. Marker color

The marker color is displayed here. You can click on the square to open a standard color selection dialog to select the marker color. Note that it selects the color of the text display of the marker the crosshairs remain in white color.

4. Marker show

Toggles marker display on the spectrum

5. Marker selection

Turn the dial button to select the marker being set up. The index of the marker appears at left.

6. Swap marker with reference marker (index 0)

Push this button to swap the current marker with marker at index 0. The marker at index 0 is the reference marker. Note that the colors are not swapped so that the marker color is associated to its index and not the marker itself.

7. Add/Remove marker

  • Press the "+" button to add a new marker with a maximum of 4 markers.
  • Press the "-" button to remove the current marker. When reference marker (index 0) is removed the marker at index 1 if it exists replaces it and thus is made the reference marker.

8. Time mantissa

The time mark of the marker is given in seconds by mantissa M and exponent E so that t(s) = M × 10E. This part controls the mantissa component M that appears on the left. The slider lets you control the decimal part from .000 to .999 and the dial button the integer part from 0 to 9.

9. Time exponent

This slider lets you control the exponent part E of the time mark so that t(s) = M × 10E. The value in exponential notation appears on the left.

Annotation markers tab

Spectrum Markers annotation dialog

1. Marker selection

Turn the dial button to select the marker being set up. The index of the marker appears at left.

2. Add/Remove marker

  • Press the "+" button to add a new marker.
  • Press the "-" button to remove the current marker.

3. Marker color

The marker color is displayed here. You can click on the square to open a standard color selection dialog to select the marker color. Note that it selects the color of the text display of the marker the crosshairs remain in white color.

4. Marker text

Type in the text of the marker to be displayed when it is selected (see "Annotations on spectrum display" next). You can enter up to 36 characters.

5. Export markers to .csv file

Export the markers to a .csv file. Colums are

  • Start: start frequency in Hz
  • Width: width in Hz
  • Text: marker text when selected
  • Show: marker show state (see 15)
    • 0: hidden
    • 1: top area or line
    • 2: full display
  • Red: red component (0..255) of marker color
  • Green: green component (0..255) of marker color
  • Blue: blue component (0..255) of marker color

The column names appear in the first line (header) of the file

6. Import markers from .csv file

Import the markers from a .csv file in the format described above.

7. Select start or Center input frequency

Use this button to select whether the input frequency next (9) should apply to marker start or center frequency

8. Input marker frequency

Enter either start or center marker frequency in Hz depending on the Start/Center button selection (8)

9. Select central frequency display

Click on this button to set the input frequency (9) to the center frequency of the spectrum

10. Duplicate marker

Duplicate the current marker in a new marker

11. Sort markers

Sort markers by increasing starting frequency

12. Show start/center frequency

The start of center frequency in Hz is displayed when the center or start inpu frequency (8) is selected respectively.

13. Show stop frequency

Displays the stop frequency of the marker in Hz

14. Marker bandwidth

Sets the bandwidth of the marker in Hz

15. Marker show state

Select how the marker is displayed

  • Hidden: marker is hidden
  • Top: only the top area or line is displayed
  • Full: marker is displayed in full with line limits and text

16: Apply show state to all

Click on this button to apply the current marker show state (15) to all markers

Annotations on spectrum display

Spectrum Markers annotation spectrum

In "top" state the markers are displayed as short lines or thin areas on the top of the spectrum. Click in the marker area to toggle between "full" and "top" states. For line markers (bandwidth 0 Hz) click close to the right of line marker.