In some test envirenment, there is loopback topology test. We should
handle this during discovery.
Signed-off-by: Jack Wang <jack_wang@usish.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Instead of blocking the entire host when the port's
queueing limit is hit, we should only block the port's
target. This will allow IO to other ports to execute.
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Acked-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
If the port takes a while to transition we could exhaust
the retries when using DID_TRANSPORT_DISRUPTED. For this
case we do not want to use any of the cmd's
retries, because if the command was running then when
it got failed the retry counter was already incremented.
And if this is the first time we are seeing the command,
(it got queued because it slipped through during the race)
then it should not have its retries incremented. The
fc class will decide the correct handling later.
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Acked-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
We'll be using the new version number scheme from now on.
The 'k' in the version in the past will be removed.
The format will be: <major>.<minor>.<sub_minor>.<iter>
A scsi-misc submission increments <sub_minor> and resets <iter>.
An scsi-rc-fixes submission, increments <iter>.
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The fc_block_scsi_eh() might return with status FAST_IO_FAIL
indicating I/O has been terminated due to fast_io_fail timeout.
In this case the rport is still blocked, so any error recovery
will be failing on this port. Hence we need to check if the
return value from fc_block_scsi_eh() is something other than 0,
in which case it should just return with that status.
Signed-off-by: Andrew Vasquez <andrew.vasquez@qlogic.com>
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
If adapter is not online, the driver will not process the response queue, even
on getting an interrupt.
Signed-off-by: Saurav Kashyap <saurav.kashyap@qlogic.com>
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Based on reading of the FCP2/4 specification, the driver cannot
expect the storage device to send FCP_RSP information. Instead,
the driver should interpret the data which is present in the frame
to base decisions on the success or failure of the system.
Signed-off-by: Andrew Vasquez <andrew.vasquez@qlogic.com>
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
By not clearing the 'login needed' nor 'login outstanding' states
for an fcport after a big-hammer (adapter reset), the driver may
not properly perform a PLOGI/PRLI sequence (and lose visibility
to the rport) during a follow-on SNS scan.
Signed-off-by: Andrew Vasquez <andrew.vasquez@qlogic.com>
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The additional increment of dsd_seg was causing the compiler to throw an array
out of bounds warning. This patch moves to a direct assignment of
cmd_pkt->fcp_data_dseg_len so that the compiler doesn't generate an array out
bounds warning.
Signed-off-by: Chad Dupuis <chad.dupuis@qlogic.com>
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Also in qla_os.c, rename the function, remove DEF_SCSI_QCMD, etc.
Signed-off-by: Madhuranath Iyengar <Madhu.Iyengar@qlogic.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Query the FC symbolic port name for reporting in the fc_host sysfs and
enable the symbolic_name attribute in the fc_host sysfs. When running
in NPIV mode, extend the symbolic port name with the devno and the
hostname. This allows better identification of Linux systems for SAN
and storage administrators.
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: Steffen Maier <maier@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The SCSI host and transport templates are the only members left in the
global zfcp_data struct. Move them out of zfcp_data and remove the
now unused zfcp_data struct. Also update the names of the register and
unregister functions to use the zfcp_scsi prefix.
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: Steffen Maier <maier@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
For task management commands, only LUN and flags are required. The
regular FCP setup already sets the LUN in the fcp_cmnd. All is
required for merging the function is setting up the TM flags.
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: Steffen Maier <maier@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Move the kmem_cache for allocating the qtcb to zfcp_fsf.c and rename
it accordingly.
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: Steffen Maier <maier@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Switch the allocation of the GPN_FT request data to the FC kmem_cache
and remove the zfcp_gpn kmem_cache.
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: Steffen Maier <maier@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Allocate the data for the GID_PN request through the new FC
kmem_cache. While updating the GID_PN code, also introduce a helper
function for initializing the CT header for FC nameserver requests.
Remove the "paranoia" check as well, the GID_PN request data does not
suddenly change.
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: Steffen Maier <maier@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
A data buffer that is passed to the hardware must not cross a page
boundary. zfcp uses a series of kmem_caches to align the data to not
cross a page boundary. Introduce a new kmem_cache for the FC requests
sent from the zfcp driver and use it for the ELS ADISC data. The goal
is to migrate to the FC kmem_cache in later patches and remove the
request specific kmem_caches.
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: Steffen Maier <maier@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
zfcp requires a mempool for the status read data blocks to resubmit
the "status read" requests at any time. Each status read data block
has the size of a page (4096 bytes) and needs to be placed in one
page.
Instead of having a kmem_cache for allocating page sized chunks, use
mempool_create_page_pool to create a mempool returning pages and
remove the zfcp kmem_cache.
Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: Steffen Maier <maier@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The ep_disconnect function could be freeing the ep
while beiscsi_conn_get_param is running. This has
the driver use the get ep param callback instead
of the get conn param to fix this.
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This pactch has iser export the address and port
of the endpoint.
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
bnx2i has some checks to try and make sure the ep
is not destroyed while the addr/port is getting
read. However, if after this check:
if (!(bnx2i_conn && bnx2i_conn->ep && bnx2i_conn->ep->hba))
goto out;
bnx2i_conn->ep is cleared by ep_disconnect then we will
oops.
This patches fixes the problem by having the driver
use the get_ep_param callback instead of get_conn_param.
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This has cxgbi use the iscsi_conn_get_addr_param helper
and the get ep callback.
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
For drivers using the ep callbacks the addr and port
are attached to the endpoint instead of the conn.
This adds a callout to the iscsi_transport to get
ep values. It also adds locking around the get
param call to make sure that ep_disconnect does
not free the LLD's ep interconnect structs from
under us (the ep has a refcount so it will not
go away but the LLD may have structs from other
subsystems that are not allocated in the ep so
we need to protect them from getting freed).
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This has iscsi_tcp use the iscsi_conn_get_addr_param
libiscsi function. It also drops the use of the libiscsi
session portal buffers, so they can be removed in
the next patches. Instead of copying the values
at bind time we get them during get() time. If we are
not connected userspace will now get -ENOTCONN,
so it knows that connection is disconnected instead
of a possible stale value.
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This adds a helper to convert a addr struct to
a string. This will be used by the drivers in
the next patches.
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The active variable on the iscsi_cls_conn is not used
so this patch removes it.
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
When iscsid restarts it does not know the connection's
endpoint, so it is getting leaked. This fixes the problem
by having the iscsi class force a disconnect before a
new connection is bound.
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
cxgb3i and cxgb4i support TEXT PDU offloading, so set
the bits to enable it.
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Signed-off-by: Eddie Wai <eddie.wai@broadcom.com>
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This is part of an effort to support send target discovery via
the iSCSI offload path.
Signed-off-by: Eddie Wai <eddie.wai@broadcom.com>
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
For scenarios where the shost is not being passed to bnx2i for the
iSCSI offload connection request, the code would consult the routing
table to select the CNIC device.
This code path will erroneously error out if the corresponding L2
interface's MTU has been setup to > 1500.
Signed-off-by: Eddie Wai <eddie.wai@broadcom.com>
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Moved all PCI_DEVICE_ID_NX2_57712(E) definitions to pci_ids.h
Signed-off-by: Eddie Wai <eddie.wai@broadcom.com>
Acked-by: Michael Chan <mchan@broadcom.com>
Acked-by: Eilon Greenstein <eilong@broadcom.com>
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
The hba will now be unregistered and freed when iSCSI offload
is not supported by the NIC.
Signed-off-by: Eddie Wai <eddie.wai@broadcom.com>
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Fixed a bug where the 64-bit LUN field for nopouts were 32-bit swapped.
This only pertains to 5771X devices.
Signed-off-by: Eddie Wai <eddie.wai@broadcom.com>
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Allow CNIC to go through the proper cleanup procedure for an endpoint
which failed to connect. Proper cleanup is necessary for the chip
to reset back to the initial state for the offloaded endpoint.
Signed-off-by: Eddie Wai <eddie.wai@broadcom.com>
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
- Add the driver debugfs framework for supporting debugfs read and write
operations, and iDiag command structure.
- Add read and write to SLI4 device PCI config space registers.
- Add the driver support of debugfs PCI config space register bits set/clear
methods to the provided bitmask.
- Add iDiag driver support for SLI4 device queue diagnostic.
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
- Make link speed not supported by port message an error message.
- Add support for new SLI failure codes add sysfs parameter to reflect the
security setting and current state.
- Add all lpfc module parameters to the /sys/modules/lpfc/parameters directory.
[jejb: fix up compile failure]
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
FC Discovery changes
- Treat received PLOGI while logged in as a relogin (unregister and reregister).
- Added a timer to delay Nport discovery when clean bit is cleared and Fabric
portname/nodename/FCID is changed.
- Invalidate Port's DID when receiving PLOGI from p2p port with CONFIG_PORT
mailbox command.
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
RRQ Implementation fixes
- Added checks to prevent a call to findnode_did in clr_active_rrq
- Added the del_sync_timer call for the rrq_tmr to the stop_hba_timers routine.
- Added a check in __lpfc_set_active_rrq for the driver unloading to prevent
adding an rrq when the driver is being removed.
- Add code to scsi_iocb_cmpl to check for the remote stop and add the rrq.
- Added the same check to els retry.
- Added code to compare the source did in the els rrq to the vports did and
chose the right exchange ID.
- Initialize the start_cmd pointer to indicate when we have looped through
all of the scsi buffers.
- Remove the need for the lock around the clearing of the active bit in the
rrq.
- Added code to clean the els and fcp xri aborted list and remove the all of
the RRQs for a deleted vport.
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Critical Errors:
- Correctly handle non-zero return lpfc_workq_post_event and return ENOMEM
- Save the irq level when locking the host_lock in lpfc_findnode_did
Bug Fixes:
- Adjust payload_length and request_length for sli4_config mailbox commands.
- Add the freed sgl/XRI to the tail of the list rather than to the head.
- Set the FC_VPORT_NEEDS_INIT_VPI on vport deletes and check it before
issuing a fdisc on an els retry.
- Only call lpfc_hba_init_link() if phba->cfg_suppress_link_up
is LPFC_INITIALIZE_LINK.
- Add support for SLI-4 Performance Hints
Signed-off-by: Alex Iannicelli <alex.iannicelli@emulex.com>
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>