Currently, userspace is expecting SNR value through NL80211_STA_INFO_SIGNAL for a disconnected client of SAP. But the driver sends RSSI value by doing noise floor to the SNR value received from firmware. Convert this back to SNR and provide to userspace as per the definition of NL80211_STA_INFO_SIGNAL and to be in sync with the existing implementation of userspace. Change-Id: Ia360424a9d44e48fae5a85cf0d2c577e92cd93be CRs-Fixed: 2552542 |
||
---|---|---|
.. | ||