1. Change to rectangular FFT window for 2D sync spectrum (ss).
2. Move 2D sync spectrum array to common block.
3. Change to quarter-symbol steps for the ss array.
4. Allow up to 4 decoding passes.
5. Wire up Fast/Normal/Deep for 2, 3, or 4 decoding passes.
6. Make minsmo=0 (instead of 1) for minimally spread JT65B/C signals.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8178 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Also some instances of non-italicized WSJT-X fixed.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8169 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
This change opens up all keyboard modifier options to UDP Reply
messages as well as double-clicks of decoded messages.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8168 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Measure check box added to FreqCal mode, check to record to fmt.all
with current calibration correction disabled, uncheck to see the
impact of the current calibration parameters.
The fmt.all file is now optionally renamed to fmt.bak when a
calibration solution is accepted. This allows users to preserve an
fmt.all file that they might have edited for best fit.
A calibration procedure might proceed thus:-
1) select FreqCal mode,
2) step through suggested calibration test frequencies deleting those
that have no usable signal,
3) enable "Menu->Tools->Execute frequency calibration cycle" and check
that suitable signals are present,
4) select a suitable FTol and T/R period,
5) check "Measure" and let the cycle complete a few times to gather
data,
6) uncheck "Measure" to complete the data capture, optionally tidy the
fmt.all file with your favourite editor,
7) push "Menu->Tools->Solve for calibration parameters" and accept if
you like what you see,
8) sit back and admire your accurately frequency calibrated station.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8167 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
This allows those who want to keep their calibration measurements
after finding a solution to calibrate their station. The fmt.all file
used to find and accept a solution is renamed to fmt.bak.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8164 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
Make calibration solution application iterative so that calibrations
can be applied sequentially if desired.
Tidy up calibration solution messages boxes and make i18n friendly.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8153 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
1. Checkbox "Double-click on call sets Tx and Rx freqs" has been removed
from the Settings -> General tab.
2. Checkbox "Lock Tx Freq" on main window is relabled "Hold Tx Freq".
3. Behavior now defaults to the "simplex" behavior in use up to code
revision r8123. In particular, double-clicking on decoded mesages
that do not contain your own call moves both Rx and Tx frequencies.
If the first callsign is your own call, only Rx freq moves.
4. If "Hold Tx Freq" is checked, double-clicking on decoded messages
moves the Rx frequency; Tx frequency is moved only if CTRL was held
down.
5. Clicking on the waterfall moves Rx and Tx frequencies as before:
Rx only on a simple click, Tx only on SHIFT-click, and both on
CTRL-click. This happens even if "Hold Tx Freq" is checked (which
is why this box is no longer labeled "Lock Tx Freq").
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8146 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
preventing double-click on a JT65 "OOO" message from populating message fields.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8143 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
automatically when Echo mode is started; clean up display of FreqCal parameters.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8131 ab8295b8-cf94-4d9e-aec4-7959e3be5d79
1. Checkbox "Lock Tx=Rx" is now labeled "Lock Tx Freq", and its meaning is
quite different. If checked, the audio Tx frequency cannot be changed.
It's like the "Lock" function on some transceivers.
2. Clicking on the Wide Graph waterfall and on lines of decoded text now
behave as follows:
Click on Action
---------------------------------------------------------------------
Waterfall: Click to set Rx frequency
Shift-click to set Tx frequency
Ctrl-click to set Rx and Tx frequencies
If Lock Tx Freq is checked, Tx freq does not move
Double-click to set Rx frequency and decode there
Decoded Text: Double-click to copy transmitting callsign to DX Call
and locator to DX Grid; change Rx frequency to decoded
signal's frequency; generate standard messages.
Tx frequency is not changed unless Ctrl is held down
and Lock Tx Freq not checked.
If this experimental behavior is adopted, some descriptions in the
User Guide and Special Mouse Commands will need to be updated.
3. Starting to implement a new function on the Tools menu,
"Solve for calibration parameters". This is not yet finished;
DO NOT USE in its present form.
git-svn-id: svn+ssh://svn.code.sf.net/p/wsjt/wsjt/branches/wsjtx@8125 ab8295b8-cf94-4d9e-aec4-7959e3be5d79