Fix ACL logging - SLOT specifig logging had quietly been broken
This commit is contained in:
parent
1b265d8368
commit
2ef0dfcd74
75
hblink.py
75
hblink.py
@ -206,8 +206,7 @@ class HBSYSTEM(DatagramProtocol):
|
||||
self._system = _name
|
||||
self._report = _report
|
||||
self._config = self._CONFIG['SYSTEMS'][self._system]
|
||||
self._laststrid1 = ''
|
||||
self._laststrid2 = ''
|
||||
self._laststrid = {1: b'', 2: b''}
|
||||
|
||||
# Define shortcuts and generic function names based on the type of system we are
|
||||
if self._config['MODE'] == 'MASTER':
|
||||
@ -357,41 +356,35 @@ class HBSYSTEM(DatagramProtocol):
|
||||
# ACL Processing
|
||||
if self._CONFIG['GLOBAL']['USE_ACL']:
|
||||
if not acl_check(_rf_src, self._CONFIG['GLOBAL']['SUB_ACL']):
|
||||
if self._laststrid != _stream_id:
|
||||
if self._laststrid[_slot] != _stream_id:
|
||||
logger.info('(%s) CALL DROPPED WITH STREAM ID %s FROM SUBSCRIBER %s BY GLOBAL ACL', self._system, int_id(_stream_id), int_id(_rf_src))
|
||||
if _slot == 1:
|
||||
self._laststrid1 = _stream_id
|
||||
else:
|
||||
self._laststrid2 = _stream_id
|
||||
self._laststrid[_slot] = _stream_id
|
||||
return
|
||||
if _slot == 1 and not acl_check(_dst_id, self._CONFIG['GLOBAL']['TG1_ACL']):
|
||||
if self._laststrid1 != _stream_id:
|
||||
if self._laststrid[_slot] != _stream_id:
|
||||
logger.info('(%s) CALL DROPPED WITH STREAM ID %s ON TGID %s BY GLOBAL TS1 ACL', self._system, int_id(_stream_id), int_id(_dst_id))
|
||||
self._laststrid1 = _stream_id
|
||||
self._laststrid[_slot] = _stream_id
|
||||
return
|
||||
if _slot == 2 and not acl_check(_dst_id, self._CONFIG['GLOBAL']['TG2_ACL']):
|
||||
if self._laststrid2 != _stream_id:
|
||||
if self._laststrid[_slot] != _stream_id:
|
||||
logger.info('(%s) CALL DROPPED WITH STREAM ID %s ON TGID %s BY GLOBAL TS2 ACL', self._system, int_id(_stream_id), int_id(_dst_id))
|
||||
self._laststrid2 = _stream_id
|
||||
self._laststrid[_slot] = _stream_id
|
||||
return
|
||||
if self._config['USE_ACL']:
|
||||
if not acl_check(_rf_src, self._config['SUB_ACL']):
|
||||
if self._laststrid != _stream_id:
|
||||
if self._laststrid[_slot] != _stream_id:
|
||||
logger.info('(%s) CALL DROPPED WITH STREAM ID %s FROM SUBSCRIBER %s BY SYSTEM ACL', self._system, int_id(_stream_id), int_id(_rf_src))
|
||||
if _slot == 1:
|
||||
self._laststrid1 = _stream_id
|
||||
else:
|
||||
self._laststrid2 = _stream_id
|
||||
self._laststrid[_slot] = _stream_id
|
||||
return
|
||||
if _slot == 1 and not acl_check(_dst_id, self._config['TG1_ACL']):
|
||||
if self._laststrid1 != _stream_id:
|
||||
if self._laststrid[_slot] != _stream_id:
|
||||
logger.info('(%s) CALL DROPPED WITH STREAM ID %s ON TGID %s BY SYSTEM TS1 ACL', self._system, int_id(_stream_id), int_id(_dst_id))
|
||||
self._laststrid1 = _stream_id
|
||||
self._laststrid[_slot] = _stream_id
|
||||
return
|
||||
if _slot == 2 and not acl_check(_dst_id, self._config['TG2_ACL']):
|
||||
if self._laststrid2 != _stream_id:
|
||||
if self._laststrid[_slot]!= _stream_id:
|
||||
logger.info('(%s) CALL DROPPED WITH STREAM ID %s ON TGID %s BY SYSTEM TS2 ACL', self._system, int_id(_stream_id), int_id(_dst_id))
|
||||
self._laststrid2 = _stream_id
|
||||
self._laststrid[_slot] = _stream_id
|
||||
return
|
||||
|
||||
# The basic purpose of a master is to repeat to the peers
|
||||
@ -562,41 +555,35 @@ class HBSYSTEM(DatagramProtocol):
|
||||
# ACL Processing
|
||||
if self._CONFIG['GLOBAL']['USE_ACL']:
|
||||
if not acl_check(_rf_src, self._CONFIG['GLOBAL']['SUB_ACL']):
|
||||
if self._laststrid != _stream_id:
|
||||
logger.debug('(%s) CALL DROPPED WITH STREAM ID %s FROM SUBSCRIBER %s BY GLOBAL ACL', self._system, int_id(_stream_id), int_id(_rf_src))
|
||||
if _slot == 1:
|
||||
self._laststrid1 = _stream_id
|
||||
else:
|
||||
self._laststrid2 = _stream_id
|
||||
if self._laststrid[_slot] != _stream_id:
|
||||
logger.info('(%s) CALL DROPPED WITH STREAM ID %s FROM SUBSCRIBER %s BY GLOBAL ACL', self._system, int_id(_stream_id), int_id(_rf_src))
|
||||
self._laststrid[_slot] = _stream_id
|
||||
return
|
||||
if _slot == 1 and not acl_check(_dst_id, self._CONFIG['GLOBAL']['TG1_ACL']):
|
||||
if self._laststrid1 != _stream_id:
|
||||
logger.debug('(%s) CALL DROPPED WITH STREAM ID %s ON TGID %s BY GLOBAL TS1 ACL', self._system, int_id(_stream_id), int_id(_dst_id))
|
||||
self._laststrid1 = _stream_id
|
||||
if self._laststrid[_slot] != _stream_id:
|
||||
logger.info('(%s) CALL DROPPED WITH STREAM ID %s ON TGID %s BY GLOBAL TS1 ACL', self._system, int_id(_stream_id), int_id(_dst_id))
|
||||
self._laststrid[_slot] = _stream_id
|
||||
return
|
||||
if _slot == 2 and not acl_check(_dst_id, self._CONFIG['GLOBAL']['TG2_ACL']):
|
||||
if self._laststrid2 != _stream_id:
|
||||
logger.debug('(%s) CALL DROPPED WITH STREAM ID %s ON TGID %s BY GLOBAL TS2 ACL', self._system, int_id(_stream_id), int_id(_dst_id))
|
||||
self._laststrid2 = _stream_id
|
||||
if self._laststrid[_slot] != _stream_id:
|
||||
logger.info('(%s) CALL DROPPED WITH STREAM ID %s ON TGID %s BY GLOBAL TS2 ACL', self._system, int_id(_stream_id), int_id(_dst_id))
|
||||
self._laststrid[_slot] = _stream_id
|
||||
return
|
||||
if self._config['USE_ACL']:
|
||||
if not acl_check(_rf_src, self._config['SUB_ACL']):
|
||||
if self._laststrid != _stream_id:
|
||||
logger.debug('(%s) CALL DROPPED WITH STREAM ID %s FROM SUBSCRIBER %s BY SYSTEM ACL', self._system, int_id(_stream_id), int_id(_rf_src))
|
||||
if _slot == 1:
|
||||
self._laststrid1 = _stream_id
|
||||
else:
|
||||
self._laststrid2 = _stream_id
|
||||
if self._laststrid[_slot] != _stream_id:
|
||||
logger.info('(%s) CALL DROPPED WITH STREAM ID %s FROM SUBSCRIBER %s BY SYSTEM ACL', self._system, int_id(_stream_id), int_id(_rf_src))
|
||||
self._laststrid[_slot] = _stream_id
|
||||
return
|
||||
if _slot == 1 and not acl_check(_dst_id, self._config['TG1_ACL']):
|
||||
if self._laststrid1 != _stream_id:
|
||||
logger.debug('(%s) CALL DROPPED WITH STREAM ID %s ON TGID %s BY SYSTEM TS1 ACL', self._system, int_id(_stream_id), int_id(_dst_id))
|
||||
self._laststrid1 = _stream_id
|
||||
if self._laststrid[_slot] != _stream_id:
|
||||
logger.info('(%s) CALL DROPPED WITH STREAM ID %s ON TGID %s BY SYSTEM TS1 ACL', self._system, int_id(_stream_id), int_id(_dst_id))
|
||||
self._laststrid[_slot] = _stream_id
|
||||
return
|
||||
if _slot == 2 and not acl_check(_dst_id, self._config['TG2_ACL']):
|
||||
if self._laststrid2 != _stream_id:
|
||||
logger.debug('(%s) CALL DROPPED WITH STREAM ID %s ON TGID %s BY SYSTEM TS2 ACL', self._system, int_id(_stream_id), int_id(_dst_id))
|
||||
self._laststrid2 = _stream_id
|
||||
if self._laststrid[_slot] != _stream_id:
|
||||
logger.info('(%s) CALL DROPPED WITH STREAM ID %s ON TGID %s BY SYSTEM TS2 ACL', self._system, int_id(_stream_id), int_id(_dst_id))
|
||||
self._laststrid[_slot] = _stream_id
|
||||
return
|
||||
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user