Remove unnecessary state variables

This commit is contained in:
n0mjs710 2019-09-06 13:43:24 -05:00
parent 553bcba3a2
commit 557b21c022

View File

@ -78,10 +78,10 @@ class bridgeallSYSTEM(HBSYSTEM):
# Status information for the system, TS1 & TS2
# 1 & 2 are "timeslot"
# In TX_EMB_LC, 2-5 are burst B-E
self.STATUS = {
1: {
'RX_START': time(),
'RX_LOSS': 0,
'RX_SEQ': '\x00',
'RX_RFS': '\x00',
'TX_RFS': '\x00',
@ -92,18 +92,10 @@ class bridgeallSYSTEM(HBSYSTEM):
'RX_TIME': time(),
'TX_TIME': time(),
'RX_TYPE': const.HBPF_SLT_VTERM,
'RX_LC': '\x00',
'TX_H_LC': '\x00',
'TX_T_LC': '\x00',
'TX_EMB_LC': {
1: '\x00',
2: '\x00',
3: '\x00',
4: '\x00',
}
},
2: {
'RX_START': time(),
'RX:LOSS': 0,
'RX_SEQ': '\x00',
'RX_RFS': '\x00',
'TX_RFS': '\x00',
@ -114,15 +106,6 @@ class bridgeallSYSTEM(HBSYSTEM):
'RX_TIME': time(),
'TX_TIME': time(),
'RX_TYPE': const.HBPF_SLT_VTERM,
'RX_LC': '\x00',
'TX_H_LC': '\x00',
'TX_T_LC': '\x00',
'TX_EMB_LC': {
1: '\x00',
2: '\x00',
3: '\x00',
4: '\x00',
}
}
}
@ -138,14 +121,21 @@ class bridgeallSYSTEM(HBSYSTEM):
if new_stream:
self.STATUS[_slot]['RX_START'] = pkt_time
self.STATUS[_slot]['RX_LOSS'] = 0
self.STATUS[_slot]['RX_SEQ'] = _seq
logger.info('(%s) *CALL START* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) TGID %s (%s), TS %s', \
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot)
else:
# This could be much better, it will have errors during roll-over
if _seq > (self.STATUS[_slot]['RX_SEQ'] + 1):
print(_seq, self.STATUS[_slot]['RX_SEQ'])
self.STATUS[_slot]['RX_LOSS'] += _seq - (self.STATUS[_slot]['RX_SEQ'] + 1)
# Final actions - Is this a voice terminator?
if (_frame_type == const.HBPF_DATA_SYNC) and (_dtype_vseq == const.HBPF_SLT_VTERM) and (self.STATUS[_slot]['RX_TYPE'] != const.HBPF_SLT_VTERM):
call_duration = pkt_time - self.STATUS[_slot]['RX_START']
logger.info('(%s) *CALL END* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) TGID %s (%s), TS %s, Duration: %s', \
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot, call_duration)
logger.info('(%s) *CALL END* STREAM ID: %s SUB: %s (%s) PEER: %s (%s) TGID %s (%s), TS %s, Loss: %s, Duration: %s', \
self._system, int_id(_stream_id), get_alias(_rf_src, subscriber_ids), int_id(_rf_src), get_alias(_peer_id, peer_ids), int_id(_peer_id), get_alias(_dst_id, talkgroup_ids), int_id(_dst_id), _slot, self.STATUS[_slot]['RX_LOSS'], call_duration)
for _target in self._CONFIG['SYSTEMS']:
@ -232,6 +222,7 @@ class bridgeallSYSTEM(HBSYSTEM):
# Mark status variables for use later
self.STATUS[_slot]['RX_RFS'] = _rf_src
self.STATUS[_slot]['RX_SEQ'] = _seq
self.STATUS[_slot]['RX_TYPE'] = _dtype_vseq
self.STATUS[_slot]['RX_TGID'] = _dst_id
self.STATUS[_slot]['RX_TIME'] = pkt_time